Articles with "anterion" as a keyword



Photo by cytonn_photography from unsplash

Anterior chamber angle imaging with swept-source optical coherence tomography: comparison between CASIAII and ANTERION

Sign Up to like & get
recommendations!
Published in 2020 at "Scientific Reports"

DOI: 10.1038/s41598-020-74813-3

Abstract: This study compared the test–retest variabilities and measurement agreement of anterior chamber angle (ACA) dimensions measured by two anterior segment swept-source optical coherence tomography (SS-OCT)—the ANTERION (Heidelberg Engineering, Heidelberg, Germany) and CASIAII (Tomey, Nagoya, Japan).… read more here.

Keywords: agreement; casiaii; chamber angle; anterior chamber ... See more keywords
Photo from wikipedia

Clinical evaluation of ocular biometry of dual Scheimpflug analyzer, GALILEI G6 and swept source optical coherence tomography, ANTERION

Sign Up to like & get
recommendations!
Published in 2022 at "Scientific Reports"

DOI: 10.1038/s41598-022-07696-1

Abstract: To evaluate the performance of a new swept source optical coherence tomography optical biometer, ANTERION, in ocular biometry and intraocular lens (IOL) calculation compared with the reference standard of Dual Scheimpflug Analyzer (GALILEI, G6). A… read more here.

Keywords: source optical; coherence tomography; biometry; anterion ... See more keywords
Photo by cytonn_photography from unsplash

Repeatability and Agreement of Two Swept-Source Optical Coherence Tomographers for Anterior Segment Parameter Measurements

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Glaucoma"

DOI: 10.1097/ijg.0000000000001989

Abstract: Purpose: The aim was to evaluate the repeatability and agreement of two swept-source optical coherence tomographers for anterior segment parameters in healthy subjects. Patients and Methods: Automated mark of scleral spur and angle recess for… read more here.

Keywords: agreement; anterion; repeatability agreement; angle ... See more keywords

Agreement between Two Swept-Source Optical Coherence Tomography Biometers and a Partial Coherence Interferometer

Sign Up to like & get
recommendations!
Published in 2022 at "Korean Journal of Ophthalmology : KJO"

DOI: 10.3341/kjo.2022.0017

Abstract: Purpose To evaluate the level of agreement between ANTERION (Heidelberg Engineering, Heidelberg, Germany), OA-2000 (Tomey, Nagoya, Japan), and IOLMaster 500 (Carl Zeiss AG, Jena, Germany). Methods Fifty-one eyes of 51 patients were included in the… read more here.

Keywords: agreement; three devices; coherence; anterion ... See more keywords
Photo from wikipedia

Comparison of Refractive Prediction Accuracy With Three Optical Devices.

Sign Up to like & get
recommendations!
Published in 2023 at "Journal of refractive surgery"

DOI: 10.3928/1081597x-20221115-02

Abstract: PURPOSE To investigate refractive prediction accuracy with the OA-2000 (Tomey), Anterion (Heidelberg Engineering), and IOLMaster 500 (Carl Zeiss Meditec AG) in patients with cataract. METHODS Patients with cataract referred for phacoemulsification were enrolled and scanned… read more here.

Keywords: anterion; prediction accuracy; iolmaster 500; refractive prediction ... See more keywords