Articles with "antitachycardia pacing" as a keyword



Photo by nci from unsplash

A Direct Comparison of a Novel Antitachycardia Pacing Algorithm Against Present Methods Using Virtual Patient Modeling.

Sign Up to like & get
recommendations!
Published in 2020 at "Heart rhythm"

DOI: 10.1016/j.hrthm.2020.05.009

Abstract: BACKGROUND Antitachycardia pacing (ATP) success rates have been reported as low as 50% for fast VTs, providing an opportunity for improved ATP to decrease shocks. A new self-adapting ATP algorithm, AATP, was compared to traditional… read more here.

Keywords: comparison novel; burst atp; aatp; direct comparison ... See more keywords
Photo by nci from unsplash

Dizziness during atrial antitachycardia pacing: What is the cause

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Cardiovascular Electrophysiology"

DOI: 10.1111/jce.14728

Abstract: A 74‐year‐old with a history of sinus node dysfunction and intermittent AV block s/p permanent pacemaker implant 6 years prior, complains of one episode of dizziness. read more here.

Keywords: pacing cause; dizziness atrial; dizziness; antitachycardia pacing ... See more keywords
Photo from wikipedia

Characteristics of successful reactive atrial‐based antitachycardia pacing in patients with cardiac implantable electronic devices: History of catheter ablation of atrial fibrillation as a predictor of high treatment efficacy

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Cardiovascular Electrophysiology"

DOI: 10.1111/jce.15551

Abstract: Reactive atrial‐based antitachycardia pacing (rATP) in patients with cardiac implantable electronic devices (CIEDs) suppresses the progression of atrial fibrillation (AF) to the persistent form. However, the clinical factors associated with successful reactive atrial‐based antitachycardia pacing… read more here.

Keywords: atrial based; antitachycardia pacing; based antitachycardia; patients cardiac ... See more keywords
Photo by robertbye from unsplash

Initial Clinical Experience With a New Automated Antitachycardia Pacing Algorithm: Feasibility and Safety in an Ambulatory Patient Cohort

Sign Up to like & get
recommendations!
Published in 2017 at "Circulation: Arrhythmia and Electrophysiology"

DOI: 10.1161/circep.116.004823

Abstract: Background: Antitachycardia pacing (ATP) in implantable cardioverter-defibrillators (ICD) decreases patient shock burden but has recognized limitations. A new automated ATP (AATP) based on electrophysiological first principles was designed. The study objective was to assess the… read more here.

Keywords: new automated; ventricular fibrillation; feasibility safety; antitachycardia pacing ... See more keywords