Sign Up to like & get
recommendations!
1
Published in 2017 at "Journal of endodontics"
DOI: 10.1016/j.joen.2017.05.012
Abstract: INTRODUCTION The purpose of this study was to evaluate in vitro the efficacy of both the electronic apex locator (EAL) and auto apical reverse (AAR) functions of the endodontic motor MM Control (Micro-Mega, Besançon Cedex, France)…
read more here.
Keywords:
function;
apex locator;
function control;
aar function ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2023 at "F1000Research"
DOI: 10.12688/f1000research.133288.1
Abstract: Background: Successful root canal treatment is influenced by the apical extent of root canal preparation and the eventual root canal filling. Achieving the full working length until the apical constriction, which is usually 0.5 –…
read more here.
Keywords:
apex locators;
apex;
working lengths;
apex locator ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Iranian Endodontic Journal"
DOI: 10.22037/iej.2017.12
Abstract: Introduction: The purpose of this in vitro study was to compare the accuracy of working length determination using the apex locator versus conventional radiography in C-shaped canals. Methods and Materials: After confirming the actual C-shaped…
read more here.
Keywords:
length;
apex locator;
conventional radiography;
working length ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2022 at "Nigerian Journal of Clinical Practice"
DOI: 10.4103/njcp.njcp_1444_21
Abstract: Aims and Background: The aim of this study was to evaluate the accuracy of the electronic actual length in detecting artificial perforations of the root canal in the presence of saline solution (NaCl, (Eczacibasi, Istanbul,…
read more here.
Keywords:
electronic apex;
apex locator;
accuracy electronic;
mtad qmix ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2022 at "Nigerian Journal of Clinical Practice"
DOI: 10.4103/njcp.njcp_27_22
Abstract: Background and Aim: This experimental study aimed to investigate the reliability of using electronic apex locator devices to determine the working length of artificial root canals. Materials and Methods: The experiments were performed using resin…
read more here.
Keywords:
apex locator;
reliability;
electronic apex;
model ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Journal of Clinical and Experimental Dentistry"
DOI: 10.4317/jced.53968
Abstract: Background Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the…
read more here.
Keywords:
apex locator;
pulpectomy primary;
conventional pulpectomy;
rotary technique ... See more keywords