Articles with "aseptic loosening" as a keyword



Photo from wikipedia

[Diagnosis of loosening after knee arthroplasty].

Sign Up to like & get
recommendations!
Published in 2021 at "Der Orthopade"

DOI: 10.1007/s00132-021-04180-y

Abstract: BACKGROUND Aseptic loosening is one of the most common reasons for revision in knee arthroplasty. Its pathogenesis is multifactorial, and early diagnosis is necessary to initiate appropriate therapy and to avoid serious complications, such as… read more here.

Keywords: computed tomography; knee arthroplasty; knee; diagnosis loosening ... See more keywords
Photo from wikipedia

Risk factors for aseptic loosening in complex revision total knee arthroplasty using rotating hinge implants

Sign Up to like & get
recommendations!
Published in 2020 at "International Orthopaedics"

DOI: 10.1007/s00264-020-04878-2

Abstract: Purpose This study aimed to determine the risk factors of aseptic loosening (AL) in complex revision total knee arthroplasty (TKA) cases using rotating hinge knee prosthesis. Methods Patients who had undergone re-revision rotating hinge prosthesis… read more here.

Keywords: rotating hinge; risk; revision; risk factors ... See more keywords
Photo from wikipedia

Revision Total Elbow Arthroplasty: Is it safe to perform a single-stage revision for presumed aseptic loosening based on clinical assessment, normal inflammatory markers and a negative aspiration?

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of shoulder and elbow surgery"

DOI: 10.1016/j.jse.2020.05.017

Abstract: BACKGROUND Revision Total Elbow Arthroplasty (TEA) is a challenging procedure that is becoming increasingly common. In our unit we regard it as essential to exclude infection as the underlying cause of TEA loosening. In all… read more here.

Keywords: single stage; revision; aseptic loosening; stage revision ... See more keywords
Photo by maxwbender from unsplash

Autophagy inhibitors 3-MA and LY294002 repress osteoclastogenesis and titanium particle-stimulated osteolysis.

Sign Up to like & get
recommendations!
Published in 2021 at "Biomaterials science"

DOI: 10.1039/d1bm00691f

Abstract: Aseptic loosening caused by peri-implant osteolysis (PIO) is a common complication after joint replacement, and there is still no better treatment than revision surgery. The wear particle-induced inflammation response, especially subsequent osteoclastic bone resorption, is… read more here.

Keywords: particle; osteolysis; autophagy; aseptic loosening ... See more keywords
Photo by anniespratt from unsplash

Prosthesis survival after revision knee arthroplasty for “pain without loosening” versus “aseptic loosening”: a Danish nationwide study

Sign Up to like & get
recommendations!
Published in 2021 at "Acta Orthopaedica"

DOI: 10.1080/17453674.2021.1999069

Abstract: Background and purpose Patients having a knee arthroplasty revision for the indication “pain without loosening” may have a higher risk of re-revisions than patients revised for other indications. The primary aim of this study was… read more here.

Keywords: revision; without loosening; aseptic loosening; pain without ... See more keywords
Photo from wikipedia

Is High-dose Radiation Therapy Associated With Early Revision Due to Aseptic Loosening in Patients With a Sarcoma of the Lower Extremities Reconstructed With a Cemented Endoprosthesis?

Sign Up to like & get
recommendations!
Published in 2022 at "Clinical Orthopaedics and Related Research"

DOI: 10.1097/corr.0000000000002360

Abstract: Abstract Background The durability of endoprostheses after limb salvage surgery is influenced by surgical factors (resection length, implant location, and residual bone quality), implant design (modular versus custom design, rotating versus fixed hinge, coating, collars,… read more here.

Keywords: revision; implant survival; radiation therapy; aseptic loosening ... See more keywords
Photo from wikipedia

A Method for Prediction of Femoral Component of Hip Prosthesis Durability due to Aseptic Loosening by Using Coffin/Manson Fatigue Model

Sign Up to like & get
recommendations!
Published in 2018 at "BioMed Research International"

DOI: 10.1155/2018/9263134

Abstract: The purpose of this work is to develop a new model estimate of the fatigue life of a hip prosthesis due to aseptic loosening as a multifactorial phenomenon. The formula developed here is a three-parameter… read more here.

Keywords: prosthesis; model; durability; aseptic loosening ... See more keywords
Photo from wikipedia

The fate of sagittal alignment in tapered uncemented femoral components in total hip arthroplasty: 889 hips followed for a minimum of 10 years

Sign Up to like & get
recommendations!
Published in 2020 at "HIP International"

DOI: 10.1177/1120700019895983

Abstract: Purpose: Aseptic loosening is rare after primary total hip arthroplasty (THA) with mostly uncemented tapered stems; however, different factors can modify the results. We question whether 3 different current femoral components and/or the surgical technique… read more here.

Keywords: hip; femoral components; group; aseptic loosening ... See more keywords
Photo from wikipedia

Differences between proximal bone remodeling in femoral revisions for aseptic loosening and periprosthetic fractures using the Wagner SL stem

Sign Up to like & get
recommendations!
Published in 2021 at "BMC Musculoskeletal Disorders"

DOI: 10.1186/s12891-021-04062-6

Abstract: Background Monoblock taper fluted stems have been reliably used to treat proximal femoral periprosthetic fractures (PFF) and femoral aseptic loosening (AL). Although proximal femoral remodeling has been observed around the Wagner Self-Locking (SL) stem, the… read more here.

Keywords: proximal femoral; revision; periprosthetic fractures; bone ... See more keywords
Photo from wikipedia

Imaging in peri-prosthetic assessment: an orthopaedic perspective

Sign Up to like & get
recommendations!
Published in 2017 at "EFORT Open Reviews"

DOI: 10.1302/2058-5241.2.160058

Abstract: As imaging techniques are ever-evolving, this article aims to provide a brief overview of the various modalities including their limitations. The ability of imaging for evaluation of implant osseo-integration will be addressed and also the… read more here.

Keywords: peri prosthetic; imaging peri; assessment orthopaedic; aseptic loosening ... See more keywords
Photo from wikipedia

Association of perioperative thromboprophylaxis on revision rate due to infection and aseptic loosening in primary total hip arthroplasty – new evidence from the Nordic Arthroplasty Registry Association (NARA)

Sign Up to like & get
recommendations!
Published in 2022 at "Acta Orthopaedica"

DOI: 10.2340/17453674.2022.2461

Abstract: Background and purpose Results regarding the impact of anticoagulants on revision rate are conflicting. We examined the association between the use of low molecular weight heparin (LMWH) or non-vitamin K oral anticoagulants (NOACs) as thromboprophylaxis… read more here.

Keywords: revision; association; aseptic loosening; due infection ... See more keywords