Articles with "axb" as a keyword



Photo by flyinggoose76 from unsplash

On Hermitian Solutions of the Split Quaternion Matrix Equation $$AXB+CXD=E$$AXB+CXD=E

Sign Up to like & get
recommendations!
Published in 2017 at "Advances in Applied Clifford Algebras"

DOI: 10.1007/s00006-017-0806-y

Abstract: In this paper, we discuss Hermitian solutions of split quaternion matrix equation $$AXB+CXD=E,$$AXB+CXD=E, where X is an unknown split quaternion Hermitian matrix, and A, B, C, D, E are known split quaternion matrices with suitable size. The objective of… read more here.

Keywords: split quaternion; axb; hermitian solutions; axb cxd ... See more keywords
Photo by nci from unsplash

14. Dosimetric and radiobiological evaluation for the clinical validation of Acuros XB algorithm in thoracic radiation therapy

Sign Up to like & get
recommendations!
Published in 2017 at "Physica Medica"

DOI: 10.1016/j.ejmp.2017.10.039

Abstract: Introduction Acuros-XB (AXB) algorithm has been introduced several years ago in order to improve the accuracy of dose calculation in radiotherapy, especially in the presence of tissue heterogeneities. This type (c) algorithm is based on… read more here.

Keywords: calculation; axb; evaluation; axb algorithm ... See more keywords
Photo by portablepeopleproductions from unsplash

30 Dosimetric impact of using Acuros XB algorithm in lung treatment for standard treatments and for hypofractionated stereotactic radiotherapy

Sign Up to like & get
recommendations!
Published in 2018 at "Physica Medica"

DOI: 10.1016/j.ejmp.2018.09.112

Abstract: Introduction The aim of this work is to analyze the dosimetric impact of using Acuros algorithm (AXB) instead of Anisotropic Analytical Algorithm (AAA) in lung treatment for standard fractions and for hypofractionated stereotactic radiotherapy using… read more here.

Keywords: dosimetric impact; using acuros; impact; treatment ... See more keywords
Photo by a2eorigins from unsplash

On the conversion from dose-to-medium to dose-to-water in heterogeneous phantoms with Acuros XB and Monte Carlo calculations.

Sign Up to like & get
recommendations!
Published in 2019 at "Physics in medicine and biology"

DOI: 10.1088/1361-6560/ab3df3

Abstract: The method implemented in Monte Carlo (MC) algorithm to convert dose-to-medium (Dm) to dose-to-water (Dw) is usually based on the Bragg-Gray cavity theory. Acuros XB (AXB) reports also Dm and Dw but the method to… read more here.

Keywords: water; dose water; conversion; axb ... See more keywords