Articles with "balloon guide" as a keyword



Photo from wikipedia

Mechanical thrombectomy with a balloon-guide catheter: sheathless transradial versus transfemoral approach.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of neurointerventional surgery"

DOI: 10.1136/jnis-2022-019607

Abstract: BACKGROUND The transradial approach (TRA) for mechanical thrombectomy (MT) for acute ischemic stroke has been limited by the size of catheters usable in the radial artery, with the smaller access site precluding balloon-guide catheter (BGC)… read more here.

Keywords: versus transfemoral; guide catheter; transfemoral approach; approach ... See more keywords
Photo by florianklauer from unsplash

Impact of balloon guide catheter on technical and clinical outcomes: a systematic review and meta-analysis

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of NeuroInterventional Surgery"

DOI: 10.1136/neurintsurg-2017-013179

Abstract: Background and purpose Flow arrest with balloon guide catheters (BGCs) is becoming increasingly recognized as critical to optimizing patient outcomes for mechanical thrombectomy. We performed a systematic review and meta-analysis of the literature for studies… read more here.

Keywords: mechanical thrombectomy; bgc; balloon guide; systematic review ... See more keywords
Photo from wikipedia

Balloon guide catheter improvements in thrombectomy outcomes persist despite advances in intracranial aspiration technology

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of NeuroInterventional Surgery"

DOI: 10.1136/neurintsurg-2020-017027

Abstract: Background First-pass effect (FPE) has been established as a key metric for technical success and strongly correlates with better clinical outcomes. Most data supporting improved outcomes with the use of a balloon guide catheter (BGC)… read more here.

Keywords: intracranial aspiration; bgc; balloon guide; technology ... See more keywords
Photo by papaioannou_kostas from unsplash

Efficacy of Balloon Guide Catheter-Assisted Thrombus Repair in Stroke Treatment: A Retrospective Survey in China

Sign Up to like & get
recommendations!
Published in 2022 at "BioMed Research International"

DOI: 10.1155/2022/4278048

Abstract: Background The first-pass (FP) effect, defined by successful cerebral reperfusion from a single pass of an endovascular stentriever, was associated with shorter procedural times and possible improved outcomes in patients with ischemic stroke secondary to… read more here.

Keywords: guide catheter; bgc; bgc group; balloon guide ... See more keywords
Photo by lanju_fotografie from unsplash

Abstract P490: Influence of Balloon Guide Catheter Use on Procedural & Clinical Outcomes in the Escape-NA1 Trial

Sign Up to like & get
recommendations!
Published in 2021 at "Stroke"

DOI: 10.1161/str.52.suppl_1.p490

Abstract: Purpose: We assessed whether balloon guide catheter (BGC) use during endovascular thrombectomy (EVT) influences procedural and clinical outcomes in the ESCAPE-NA1 trial. Methods: ESCAPE-NA1 was an ... read more here.

Keywords: escape na1; guide catheter; outcomes escape; procedural clinical ... See more keywords
Photo from wikipedia

Safety and feasibility of transradial use of 8F balloon guide catheter Flowgate2 for endovascular thrombectomy in acute ischemic stroke

Sign Up to like & get
recommendations!
Published in 2021 at "Interventional Neuroradiology"

DOI: 10.1177/15910199211013186

Abstract: Background While Balloon Guide Catheters (BGC) have been shown to increase the rate of reperfusion during mechanical thrombectomy (MT), its implementation with transfemoral approach is at times limited due to unfavorable vascular anatomy. Objective to… read more here.

Keywords: thrombectomy; catheter; balloon guide; use ... See more keywords
Photo from wikipedia

Effect of Early Balloon Inflation of Balloon Guide Catheter in Mechanical Thrombectomy for Large Vessel Occlusion.

Sign Up to like & get
recommendations!
Published in 2023 at "Current neurovascular research"

DOI: 10.2174/1567202620666230404125627

Abstract: OBJECTIVE A balloon guide catheter (BGC) is widely used in mechanical thrombectomy (MT). However, the balloon inflation timing of BGC has not been clearly established. We evaluated whether balloon inflation timing of BGC affects the… read more here.

Keywords: catheter; balloon; early balloon; inflation ... See more keywords
Photo from wikipedia

Clinical and Procedural Outcomes with or without Balloon Guide Catheters during Endovascular Thrombectomy in Acute Ischemic Stroke: A Systematic Review and Meta-analysis with First-line Technique Subgroup Analysis

Sign Up to like & get
recommendations!
Published in 2021 at "American Journal of Neuroradiology"

DOI: 10.3174/ajnr.a7164

Abstract: BACKGROUND: Balloon guide catheters are increasingly used to improve clot retrieval by temporarily stopping proximal blood flow during endovascular thrombectomy. PURPOSE: Our aim was to provide a summary of the literature comparing the procedural and… read more here.

Keywords: guide catheters; balloon guide; analysis; endovascular thrombectomy ... See more keywords
Photo from wikipedia

Role of Balloon Guide Catheter in Modern Endovascular Thrombectomy

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Korean Neurosurgical Society"

DOI: 10.3340/jkns.2019.0114

Abstract: Proximal flow control achieved with a balloon guide catheter (BGC) during endovascular treatment of acute ischemic stroke is reviewed in this article. In clinical practice, BGCs offer a multi-faceted approach for clot retrieval by creating… read more here.

Keywords: thrombectomy; role balloon; balloon guide; guide catheter ... See more keywords