Articles with "based neutron" as a keyword



Optimization of Linac-based neutron source for thermal neutron activation analysis

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Radioanalytical and Nuclear Chemistry"

DOI: 10.1007/s10967-018-6041-8

Abstract: A 20 MeV electron Linac based neutron beam has been shaped for neutron activation analysis (NAA) technique. A beam shaping assembly (BSA) has been simulated using MCNPX2.6 code to increase the thermal neutron flux and decrease… read more here.

Keywords: based neutron; activation analysis; neutron activation; thermal neutron ... See more keywords

Metal halide perovskite for neutron scintillators and direct detection

Sign Up to like & get
recommendations!
Published in 2025 at "Applied Physics Reviews"

DOI: 10.1063/5.0249624

Abstract: Neutron detection has significantly applied in security inspection and border control, high-energy physics, medical diagnostics, and nuclear monitoring. Recently, as one of the alternative materials, metal halide perovskites (MHPs) show great potential in high-performance neutron… read more here.

Keywords: detection; based neutron; neutron detectors; metal halide ... See more keywords

Application of fiber and SiPM based neutron detector in white neutron measurements

Sign Up to like & get
recommendations!
Published in 2025 at "Journal of Instrumentation"

DOI: 10.1088/1748-0221/20/11/p11013

Abstract: To enable monitoring of neutron physics parameters during the operation of liquid lead-bismuth targets, a fiber based neutron detector system for neutron flux measurement was developed. The system comprises a scintillator probe, quartz optical fiber,… read more here.

Keywords: based neutron; neutron flux; neutron detector; detector ... See more keywords

A Plutonium Mass Uncertainty Assessment Using a Cherenkov-Based Neutron Multiplicity Water Detector

Sign Up to like & get
recommendations!
Published in 2020 at "IEEE Transactions on Nuclear Science"

DOI: 10.1109/tns.2020.3027668

Abstract: We present a new analysis of the sensitivity of a water Cherenkov-based neutron multiplicity counter for nondestructive assay of trace quantities of 240Pu. The multiplicity counter [water-based neutron detector (WaND)] contains 1.0 m3 of water… read more here.

Keywords: cherenkov based; water; based neutron; detector ... See more keywords
Photo from wikipedia

Development of Optical-fiber-based Neutron Detector Using Li-glass Scintillator for an Intense Neutron Field

Sign Up to like & get
recommendations!
Published in 2020 at "Sensors and Materials"

DOI: 10.18494/sam.2020.2748

Abstract: The development of a neutron detector for real-time measurements in an intense neutron field is desired. We are developing a quartz optical-fiber-based neutron detector as a real-time neutron monitor. Thus far, Eu:LiCaAlF6 crystals and LiF/Eu:CaF2… read more here.

Keywords: based neutron; neutron detector; fiber based; detector ... See more keywords