Articles with "beam hardening" as a keyword



CT sinogram‐consistency learning for metal‐induced beam hardening correction

Sign Up to like & get
recommendations!
Published in 2018 at "Medical Physics"

DOI: 10.1002/mp.13199

Abstract: PURPOSE This paper proposes a sinogram-consistency learning method to deal with beam hardening-related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent sinogram that does… read more here.

Keywords: beam hardening; sinogram consistency; learning method; consistency learning ... See more keywords

Beam-hardening in 70-kV Coronary CT angiography: Artifact reduction using an advanced post-processing algorithm.

Sign Up to like & get
recommendations!
Published in 2018 at "European journal of radiology"

DOI: 10.1016/j.ejrad.2018.02.016

Abstract: PURPOSE To investigate the effect of an iterative beam-hardening correction algorithm (iBHC) on artifact reduction and image quality in coronary CT angiography (cCTA) with low tube voltage. MATERIAL AND METHODS Thirty-six patients (17 male, mean… read more here.

Keywords: image quality; algorithm; beam hardening; artifact reduction ... See more keywords

X-ray computed tomography: Practical evaluation of beam hardening in iron ore samples

Sign Up to like & get
recommendations!
Published in 2019 at "Minerals Engineering"

DOI: 10.1016/j.mineng.2018.11.010

Abstract: Abstract X-ray computed tomography is a non-destructive 3D analytical technique, which in recent years has gained more widespread applications to characterise the internal structure of materials in minerals processing and metallurgical studies. Successful application of… read more here.

Keywords: mineralogy; beam hardening; sample; iron ore ... See more keywords

Decomposing a prior-CT-based cone-beam CT projection correction algorithm into scatter and beam hardening components

Sign Up to like & get
recommendations!
Published in 2017 at "Physics and Imaging in Radiation Oncology"

DOI: 10.1016/j.phro.2017.09.002

Abstract: Abstract A scatter correction algorithm (SCA) for cone beam CT (CBCT) projections, making use of prior information obtained by deformable image registration of CT to CBCT, has recently been proposed and tested for particle therapy… read more here.

Keywords: beam hardening; correction; cone beam; correction algorithm ... See more keywords

Comparative performance assessment of beam hardening correction algorithms applied on simulated data sets

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Microscopy"

DOI: 10.1111/jmi.12746

Abstract: Beam hardening artefacts deteriorate the reconstructed image quality in industrial computed tomography. The appearances of beam hardening artefacts can be cupping effects or streaks. They impair the image fidelity to the object being scanned. This… read more here.

Keywords: hardening correction; algorithm; beam hardening; hardening artefacts ... See more keywords

Beam hardening artifacts of liquid embolic agents: comparison between Squid and Onyx

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of NeuroInterventional Surgery"

DOI: 10.1136/neurintsurg-2018-014542

Abstract: Background Initial clinical experience with Squid shows subjectively reduced artifacts on post-embolization CT scans compared with Onyx. To further investigate these observations, we aimed to perform a comparison of artifacts between Squid and Onyx in… read more here.

Keywords: hardening artifacts; beam hardening; flat panel; squid ... See more keywords

Beam hardening correction in polychromatic x-ray grating interferometry.

Sign Up to like & get
recommendations!
Published in 2017 at "Optics express"

DOI: 10.1364/oe.25.024690

Abstract: The beam hardening is one of the two causes of the fringe shift distortion in polychromatic X-ray grating interferometry. Based on the assumption of the uniform energy dependence, we developed a novel analytic approach to… read more here.

Keywords: ray grating; beam hardening; polychromatic ray; grating interferometry ... See more keywords
Photo from wikipedia

A new approach for reducing beam hardening artifacts in polychromatic X-ray computed tomography using more accurate prior image.

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of X-ray science and technology"

DOI: 10.3233/xst-17325

Abstract: PURPOSE Metal artifacts severely degrade CT image quality in clinical diagnosis, which are difficult to removed, especially for the beam hardening artifacts. The metal artifact reduction (MAR) based on prior images are the most frequently-used… read more here.

Keywords: image; beam hardening; metal; prior image ... See more keywords

Characteristics of the Novel Electron Beam Hardening Technology for Submicron Bainitic Steels in the Context of Its Application in the Production of Gears and Comparison with the Competitive Laser Beam Technology

Sign Up to like & get
recommendations!
Published in 2025 at "Coatings"

DOI: 10.3390/coatings15111321

Abstract: The objective of this study was to investigate electron beam hardening (EBH) technology and compare its performance with laser beam hardening (LBH) in the context of manufacturing components such as gears, which increasingly employ submicron… read more here.

Keywords: technology; electron beam; beam hardening; beam ... See more keywords

Comparison of beam hardening effect of physical and enhanced dynamic wedges at bladder inhomogeneity using EBT3 film dosimeter

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Cancer Research and Therapeutics"

DOI: 10.4103/0973-1482.206244

Abstract: Introduction: Using physical wedges (PWs) to modify dose distribution and more homogeneous target coverage is a well-established technique. However, there are many problems with PWs known as beam hardening, which made them problematic. This can… read more here.

Keywords: comparison beam; dynamic wedges; beam hardening; enhanced dynamic ... See more keywords

Expression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images

Sign Up to like & get
recommendations!
Published in 2024 at "Imaging Science in Dentistry"

DOI: 10.5624/isd.20240061

Abstract: Purpose This study was performed to evaluate the expression of beam hardening artifacts generated by high atomic number materials in stitched cone-beam computed tomography (CBCT) images, compared to the traditional acquisition mode. Materials and Methods… read more here.

Keywords: stitched cone; beam hardening; hardening artifacts; beam ... See more keywords