Articles with "beam monitoring" as a keyword



Characterization of a shielded beam current transformer for ultra‐high dose rate (FLASH) electron beam monitoring and dose reporting

Sign Up to like & get
recommendations!
Published in 2025 at "Medical Physics"

DOI: 10.1002/mp.17927

Abstract: Real‐time beam monitoring and accurate dose reporting is challenging in ultra‐high dose rate (UHDR) electron beams. Although beam current transformers (BCTs) can effectively track parameters such as pulse width (PW) and repetition frequency for UHDR… read more here.

Keywords: beam monitoring; dose; beam; dose reporting ... See more keywords

Monolithic HV-CMOS sensors for a beam monitoring system of therapeutic ion beams

Sign Up to like & get
recommendations!
Published in 2024 at "Journal of Instrumentation"

DOI: 10.1088/1748-0221/19/03/c03043

Abstract: Nowadays, cancer treatment with ion beam is well established and studied. This method allows to deposit the maximum dose to the tumor and minimize the damage to healthy tissue, due to the Bragg peak of… read more here.

Keywords: beam monitoring; system; ion beams; monitoring system ... See more keywords

A novel silicon pixel sensor for beam monitoring applications at heavy-ion accelerators

Sign Up to like & get
recommendations!
Published in 2024 at "Journal of Instrumentation"

DOI: 10.1088/1748-0221/19/04/c04039

Abstract: This paper describes a silicon pixel sensor for non-interceptive real-time beam monitoring at heavy-ion accelerators. The total size of the sensor is 4 mm × 5 mm. It has 64 (row) × 120 (column) square… read more here.

Keywords: beam monitoring; heavy ion; sensor; silicon pixel ... See more keywords

Simulation study for the energy and position reconstruction performances of the beam monitoring system of Carbon Ion Radiation Therapy using GEANT4

Sign Up to like & get
recommendations!
Published in 2025 at "PLOS ONE"

DOI: 10.1371/journal.pone.0313862

Abstract: Carbon Ion Radiation Therapy is operated in several countries because of its advantage to have high dose concentration and/or high linear energy transfer (LET). To estimate the beam performance of Carbon Ion Radiation Therapy, we… read more here.

Keywords: beam monitoring; ion radiation; energy; carbon ion ... See more keywords
Photo from wikipedia

Development of a Daily-Treatment Beam-Monitoring System Based Gafchromic EBT3 Film for Pencil-Beam Scanning Proton Therapy

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of the Korean Physical Society"

DOI: 10.3938/jkps.76.769

Abstract: This study describes the development of a simple method to assess inter-fractional deviations of delivered proton beams in treatment rooms. To monitor the treatment beam, we measured the field-by-field beam fluences by attaching the EBT3… read more here.

Keywords: monitoring system; treatment; ebt3 film; beam monitoring ... See more keywords