Articles with "biometer" as a keyword



Photo by aiony from unsplash

Comparison of biometry and intraocular lens power calculation performed by a new optical biometry device and a reference biometer.

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of cataract and refractive surgery"

DOI: 10.1016/j.jcrs.2016.11.033

Abstract: PURPOSE To compare biometry measurements and intraocular lens (IOL) power calculations obtained by a new optical A-scan interferometer biometer (Galilei G6) (new biometer) and a partial coherence interferometer biometer (IOLMaster 500) (reference biometer). SETTING Private… read more here.

Keywords: biometer; reference biometer; power; iol power ... See more keywords
Photo by nimbus_vulpis from unsplash

Comparison of a new Scheimpflug imaging combined with partial coherence interferometry biometer and a low-coherence reflectometry biometer.

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of cataract and refractive surgery"

DOI: 10.1016/j.jcrs.2017.08.016

Abstract: PURPOSE To evaluate the repeatability of a new biometer using Scheimpflug technology combined with partial coherence interferometry (PCI) (Pentacam AXL) and its agreement with a device based on optical low-coherence reflectometry (OLCR), the Allegro Biograph.… read more here.

Keywords: biometer; coherence; partial coherence; repeatability ... See more keywords
Photo by brandsandpeople from unsplash

Agreement of ocular biometry measurements between 2 biometers.

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of cataract and refractive surgery"

DOI: 10.1016/j.jcrs.2019.03.016

Abstract: PURPOSE To establish the agreement of routine measurements taken before cataract surgery between the Aladdin biometer, which is based on optical low-coherence interferometry (OLCI), and the Lenstar biometer, which is based on optical low-coherence reflectometry… read more here.

Keywords: agreement; biometer; agreement ocular; olci biometer ... See more keywords
Photo by chasta03 from unsplash

Swept-Source Optical Coherence Tomography Biometer as Screening Strategy for Macular Disease in Patients Scheduled for Cataract Surgery

Sign Up to like & get
recommendations!
Published in 2019 at "Scientific Reports"

DOI: 10.1038/s41598-019-46243-3

Abstract: The aim of this study was to assess the central macular imaging captured with an optical biometer based on full-eye-length Swept-Source OCT (SS-OCT) scan as a screening strategy for identifying macular diseases in patients scheduled… read more here.

Keywords: biometer; swept source; oct; patients scheduled ... See more keywords
Photo by wtrsnvc from unsplash

COMPARATIVE ANALYSIS OF 2 BIOMETERS USING SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY TECHNOLOGY.

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of cataract and refractive surgery"

DOI: 10.1097/j.jcrs.0000000000000704

Abstract: PURPOSE To report the repeatability, level of agreement and correlation of 2 swept-source optical coherence tomography (SS-OCT) biometers, the IOLMaster 700® (biometer A, Carl Zeiss, Germany) and the Anterion® (biometer B, Heidelberg Engineering GmbH, Heidelberg,… read more here.

Keywords: optical coherence; biometer; repeatability; swept source ... See more keywords
Photo from wikipedia

Evaluation of Axial Length Measurement Using Enhanced Retina Visualization Mode of the Swept-Source Optical Coherence Tomography Biometer in Dense Cataract

Sign Up to like & get
recommendations!
Published in 2021 at "Ophthalmic Research"

DOI: 10.1159/000515054

Abstract: Introduction: It has been reported that even using the swept-source (SS) optical coherence biometer, it is challenging to measure the axial length (AL) in cases with advanced cataracts. The enhanced retina visualization (ERV) mode, which… read more here.

Keywords: optical coherence; biometer; mode; swept source ... See more keywords
Photo by robertbye from unsplash

Comparison of a New Optical Biometer That Combines Scheimpflug Imaging With Partial Coherence Interferometry With That of an Optical Biometer Based on Swept-Source Optical Coherence Tomography and Placido-Disk Topography

Sign Up to like & get
recommendations!
Published in 2021 at "Frontiers in Medicine"

DOI: 10.3389/fmed.2021.814519

Abstract: Purpose To evaluate measurement precision and to compare the Pentacam AXL (Oculus Optikgeräte, Wetzlar, German), a new optical biometer based on Scheimpflug imaging and partial coherence interferometry (PCI) with that of the OA-2000 biometer (Tomey,… read more here.

Keywords: coherence; new optical; biometer; biometer based ... See more keywords