Articles with "blalock taussig" as a keyword



Photo from wikipedia

Multiscale Modeling of a Modified Blalock-Taussig Surgery in a Patient-Specific Tetralogy of Fallot.

Sign Up to like & get
recommendations!
Published in 2021 at "International journal for numerical methods in biomedical engineering"

DOI: 10.1002/cnm.3436

Abstract: Tetralogy of Fallot (TOF) is a congenital heart anomaly that causes a drastic reduction in the oxygen level. In this study, we coupled a lumped-parameter model with a patient-specific three-dimensional (3D) model which included a… read more here.

Keywords: patient specific; blalock taussig; model; modified blalock ... See more keywords
Photo from wikipedia

Duct Stenting vs. Modified Blalock-Taussig Shunt: New Insights Learned From High-Risk Patients With Duct-Dependent Pulmonary Circulation

Sign Up to like & get
recommendations!
Published in 2022 at "Frontiers in Cardiovascular Medicine"

DOI: 10.3389/fcvm.2022.933959

Abstract: Background As no data were available on the comparison of outcomes between modified Blalock-Taussig shunts (MBTs) vs. duct-stenting (DS) in patients with pulmonary atresia (PA) and an increased ductal tortuosity and in patients with pulmonary… read more here.

Keywords: duct; duct stenting; patients duct; blalock taussig ... See more keywords
Photo from wikipedia

Reproducing Patient-Specific Hemodynamics in the Blalock–Taussig Circulation Using a Flexible Multi-Domain Simulation Framework: Applications for Optimal Shunt Design

Sign Up to like & get
recommendations!
Published in 2017 at "Frontiers in Pediatrics"

DOI: 10.3389/fped.2017.00078

Abstract: For babies born with hypoplastic left heart syndrome, several open-heart surgeries are required. During Stage I, a Norwood procedure is performed to construct an appropriate circulation to both the systemic and the pulmonary arteries. The… read more here.

Keywords: shunt design; blalock taussig; hemodynamics; circulation ... See more keywords
Photo by thinkmagically from unsplash

The Effects of the Mechanical Properties of Vascular Grafts and an Anisotropic Hyperelastic Aortic Model on Local Hemodynamics during Modified Blalock–Taussig Shunt Operation, Assessed Using FSI Simulation

Sign Up to like & get
recommendations!
Published in 2022 at "Materials"

DOI: 10.3390/ma15082719

Abstract: Cardiovascular surgery requires the use of state-of-the-art artificial materials. For example, microporous polytetrafluoroethylene grafts manufactured by Gore-Tex® are used for the treatment of cyanotic heart defects (i.e., modified Blalock–Taussig shunt). Significant mortality during this palliative… read more here.

Keywords: shunt; blalock taussig; model; mechanical properties ... See more keywords