Articles with "blood pumps" as a keyword



Photo from wikipedia

The Hemopump™, The First Intravascular Ventricular Assist Device.

Sign Up to like & get
recommendations!
Published in 2019 at "ASAIO Journal"

DOI: 10.1097/mat.0000000000000802

Abstract: Development of durable left ventricular assist devices (LVADs), based on rotary flow blood pumps, began in earnest after the successful implantation of a catheter-mounted axial flow blood pump via intravascular access in 1988. This device,… read more here.

Keywords: blood pumps; blood; flow blood; ventricular assist ... See more keywords
Photo from wikipedia

Hydraulic Characterization of Implantable Rotary Blood Pumps

Sign Up to like & get
recommendations!
Published in 2019 at "IEEE Transactions on Biomedical Engineering"

DOI: 10.1109/tbme.2018.2876840

Abstract: Objective: The hydraulic properties of implantable rotary blood pumps (RBPs) determine their interaction with the cardiovascular system. A systematic comparison in this regard has not yet been performed for different clinically used RBPs. The aim… read more here.

Keywords: blood pumps; four rbps; rbps; implantable rotary ... See more keywords
Photo from wikipedia

Hemolytic Footprint of Rotodynamic Blood Pumps

Sign Up to like & get
recommendations!
Published in 2022 at "IEEE Transactions on Biomedical Engineering"

DOI: 10.1109/tbme.2022.3146135

Abstract: Objective: In preclinical examinations, rotodynamic blood pumps (RBPs) are predominantly evaluated at design-point conditions. In clinical practice, however, they run at diversified modes of operation. This study aimed at extending current preclinical evaluation of hemolytic… read more here.

Keywords: operation; blood pumps; hemolysis; blood ... See more keywords
Photo by kellysikkema from unsplash

The influence of non-conformal grid interfaces on the results of large eddy simulation of centrifugal blood pumps.

Sign Up to like & get
recommendations!
Published in 2022 at "Artificial organs"

DOI: 10.1111/aor.14263

Abstract: BACKGROUND Computational fluid dynamics has been widely used to assist the design and evaluation of blood pumps. Discretization errors associated with computational grid may influence the credibility of numerical simulations. Non-conformal grid interfaces commonly exist… read more here.

Keywords: non conformal; blood pumps; grid interfaces; centrifugal blood ... See more keywords
Photo from wikipedia

Low-flow assessment of current ECMO/ECCO2R rotary blood pumps and the potential effect on hemocompatibility

Sign Up to like & get
recommendations!
Published in 2019 at "Critical Care"

DOI: 10.1186/s13054-019-2622-3

Abstract: BackgroundExtracorporeal carbon dioxide removal (ECCO2R) uses an extracorporeal circuit to directly remove carbon dioxide from the blood either in lieu of mechanical ventilation or in combination with it. While the potential benefits of the technology… read more here.

Keywords: blood flow; rotary blood; blood pumps; blood ... See more keywords
Photo by aminmoshrefi from unsplash

A comprehensive comparison of the in vitro hemocompatibility of extracorporeal centrifugal blood pumps

Sign Up to like & get
recommendations!
Published in 2023 at "Frontiers in Physiology"

DOI: 10.3389/fphys.2023.1136545

Abstract: Purpose: Blood damage has been associated with patients under temporary continuous-flow mechanical circulatory support. To evaluate the side effects caused by transit blood pumping, in vitro hemocompatibility testing for blood damage in pumps is considered… read more here.

Keywords: hemocompatibility; blood pumps; vitro hemocompatibility; blood ... See more keywords