Articles with "bone implant" as a keyword



Photo from wikipedia

Finite Element comparison of the effect of absorbers' design in the surrounding bone of dental implants.

Sign Up to like & get
recommendations!
Published in 2019 at "International journal for numerical methods in biomedical engineering"

DOI: 10.1002/cnm.3270

Abstract: Despite the high success rate achieved in current dental implantation, there are still important problems to solve like incomplete early osteointegration, bone damage and long-term implant loosening. Highly compliant stress absorbers are a possible solution… read more here.

Keywords: finite element; effect; bone; bone implant ... See more keywords
Photo by rodsot from unsplash

Efficacy of cone-beam computed tomography with modified gray-scale range versus digital periapical radiography for the assessment of bone-implant interface gaps.

Sign Up to like & get
recommendations!
Published in 2021 at "Oral radiology"

DOI: 10.1007/s11282-021-00529-3

Abstract: OBJECTIVES To compare the efficacy of digital periapical (PA) radiography with cone-beam computed tomography (CBCT) by altering the gray-scale range for the detection of bone-implant interface gaps. METHODS Titanium implants were placed in 52 blocks… read more here.

Keywords: implant interface; gray scale; radiography; bone implant ... See more keywords
Photo from wikipedia

Salt Preform Texturing of Absorbable Zn Substrates for Bone-Implant Applications

Sign Up to like & get
recommendations!
Published in 2020 at "JOM"

DOI: 10.1007/s11837-019-03971-1

Abstract: Surface roughness is an important factor in improving the bone-implant contact area to enhance bone regeneration, yet this aspect has not been applied to absorbable metals. Textured zinc surfaces with varying degrees of surface roughness… read more here.

Keywords: implant applications; texturing absorbable; surface roughness; salt preform ... See more keywords
Photo by syahrilfdilla_id from unsplash

A novel electrochemical determination for the anti-osteoporosis drug (alendronate sodium) and its application for corrosion monitoring of surgical 316 L SS bone implant

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Alloys and Compounds"

DOI: 10.1016/j.jallcom.2017.05.016

Abstract: Abstract Low cost and simply produced electrochemical silver nanoparticles modified graphene oxide (SNMGO) sensor was constructed to monitor 1 mM Alendronate sodium (ALN) drug. The corrosion behavior of surgical 316 L stainless steel (SS) as bone implant… read more here.

Keywords: alendronate sodium; electrochemical determination; bone implant; corrosion ... See more keywords
Photo from wikipedia

Bone healing response in cyclically loaded implants

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of the mechanical behavior of biomedical materials"

DOI: 10.1016/j.jmbbm.2018.05.044

Abstract: When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micro-motion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is… read more here.

Keywords: bone healing; bone; bone implant; response cyclically ... See more keywords
Photo by hostreviews from unsplash

Comparison of micro-computed tomography and histomorphometry in the measurement of bone-implant contact ratios.

Sign Up to like & get
recommendations!
Published in 2019 at "Oral surgery, oral medicine, oral pathology and oral radiology"

DOI: 10.1016/j.oooo.2018.12.023

Abstract: OBJECTIVE The purpose of this study was to measure the 3-dimensional (3D) bone-to-implant contact (BIC) ratios calculated with an associated software algorithm on 3D micro-computed tomography (μCT) scans and compare them with measurements made with… read more here.

Keywords: implant contact; bic ratios; bone implant; computed tomography ... See more keywords
Photo from wikipedia

Biological Response to Recombinant Human Bone Morphogenetic Protein-2 on Bone-Implant Osseointegration in Ovariectomized Experimental Design

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Craniofacial Surgery"

DOI: 10.1097/scs.0000000000004992

Abstract: Objective: The aim of this study is to investigate the effects of recombinant human bone morphogenetic protein-2 (rhBMP-2) on bone-implant osteointegration in osteoporotic rats. Materials and Methods: Thirty-six female Wistar rats were randomly divided into… read more here.

Keywords: implant osseointegration; bone implant; bone; ovx rhbmp ... See more keywords
Photo by laurenmancke from unsplash

Correlation Between Conditional Approval and Customized Bone Implant Devices

Sign Up to like & get
recommendations!
Published in 2019 at "Orthopaedic Surgery"

DOI: 10.1111/os.12415

Abstract: This report aims to summarize key concerns regarding customized devices and conditional approval during the premarket evaluation of bone implants, and to explore the correlation between them. Based on the experience of approval of the… read more here.

Keywords: bone implant; customized devices; correlation conditional; conditional approval ... See more keywords
Photo from wikipedia

Influence of Deformation and Stress between Bone and Implant from Various Bite Forces by Numerical Simulation Analysis

Sign Up to like & get
recommendations!
Published in 2017 at "BioMed Research International"

DOI: 10.1155/2017/2827953

Abstract: Endosseous oral implant is applied for orthodontic anchorage in subjects with multiple tooth agenesis. Its effectiveness under orthodontic loading has been demonstrated clinically and experimentally. This study investigates the deformation and stress on the bone… read more here.

Keywords: stress bone; deformation stress; implant; bone ... See more keywords
Photo by syahrilfdilla_id from unsplash

A Comparison between the Implant Stability Quotient and the Fractal Dimension of Alveolar Bone at the Implant Site

Sign Up to like & get
recommendations!
Published in 2018 at "BioMed Research International"

DOI: 10.1155/2018/4357627

Abstract: Objectives Fractal analysis of the radiographic pattern of bone has been used to evaluate its quantitative properties. However, the relation between initial implant stability and quality of bone remains unclear. The objective of this study… read more here.

Keywords: fractal dimension; bone; implant stability; bone implant ... See more keywords
Photo from wikipedia

Comparison of three-dimensional digital analyses and two-dimensional histomorphometric analyses of the bone-implant interface

Sign Up to like & get
recommendations!
Published in 2022 at "PLoS ONE"

DOI: 10.1371/journal.pone.0276269

Abstract: Histological analysis is considered to be the gold standard method of evaluating osseointegration around a bone-implant. However, this method requires invasive specimen preparation and is capable of representing only one plane. By comparison, micro-computed tomography… read more here.

Keywords: two dimensional; bone; bone implant; three dimensional ... See more keywords