Articles with "calibration method" as a keyword



Photo by wdtoro from unsplash

PSD Integrated Calibration Method Based on Annunciator in Vacuum Environment

Sign Up to like & get
recommendations!
Published in 2020 at "International Journal of Precision Engineering and Manufacturing"

DOI: 10.1007/s12541-020-00328-6

Abstract: In this paper, an integrated calibration method for position sensitive detector (PSD) of moving support mechanism in vacuum plasma environment is proposed. That is, the PSD is used to track the laser spot to restore… read more here.

Keywords: calibration method; integrated calibration; calibration; psd ... See more keywords
Photo by libby_penner from unsplash

Extended virtual in-situ calibration method in building systems using Bayesian inference

Sign Up to like & get
recommendations!
Published in 2017 at "Automation in Construction"

DOI: 10.1016/j.autcon.2016.10.008

Abstract: Abstract Measurements from sensors and knowledge of key parameters are of great importance in the operation of modern building systems. Accurate and reliable information as these serves as the base for ensuring the desired performance… read more here.

Keywords: bayesian inference; virtual situ; calibration method; situ calibration ... See more keywords
Photo by cokdewisnu from unsplash

A machine learning field calibration method for improving the performance of low-cost particle sensors

Sign Up to like & get
recommendations!
Published in 2021 at "Building and Environment"

DOI: 10.1016/j.buildenv.2020.107457

Abstract: Abstract Measurements of airborne particles in buildings with low-cost optical particle counters (OPCs) are often inaccurate and subject to uncertainties. This study introduces a methodology to improve the performance of low-cost OPCs in measuring indoor… read more here.

Keywords: machine learning; calibration method; field calibration; field ... See more keywords
Photo from wikipedia

Enhanced just-in-time soft sensor calibration method using data density estimation

Sign Up to like & get
recommendations!
Published in 2017 at "Chemometrics and Intelligent Laboratory Systems"

DOI: 10.1016/j.chemolab.2016.12.015

Abstract: Abstract Soft sensor is an efficacious solution to predict the hard-to-measure target variable by using the process variables. In practical application scenarios, however, the target feedback cycle is usually larger than that of process variables… read more here.

Keywords: calibration method; method; soft sensor; data density ... See more keywords
Photo from wikipedia

An improved calibration method of the K&C model for modeling steel-fiber reinforced concrete

Sign Up to like & get
recommendations!
Published in 2021 at "Composite Structures"

DOI: 10.1016/j.compstruct.2021.114010

Abstract: Abstract The K&C material model, one of the widely used concrete models implemented in LS-DYNA for blast or impact analysis, is modified to improve its numerical accuracy for steel-fiber reinforced concrete (SFRC). Many input parameters… read more here.

Keywords: steel fiber; fiber reinforced; calibration method; method ... See more keywords
Photo by jamesbold from unsplash

An accurate calibration method for non-overlapping cameras with double-sided telecentric lenses

Sign Up to like & get
recommendations!
Published in 2017 at "Optik"

DOI: 10.1016/j.ijleo.2016.11.156

Abstract: Abstract In the application of displacement-relay videometrics for surface subsidence surveillance, double-sided telecentric lenses are especially suited as their constant perspective and large magnification among depth of field. As a serial camera network, it is… read more here.

Keywords: calibration method; sided telecentric; telecentric lenses; double sided ... See more keywords
Photo from wikipedia

Calibration method for binocular vision with large FOV based on normalized 1D homography

Sign Up to like & get
recommendations!
Published in 2020 at "Optik"

DOI: 10.1016/j.ijleo.2019.163556

Abstract: Abstract Calibration method for binocular vision with large field of view (FOV) is the key technology in visual measurement system. The method based on 1D targets has been widely studied due to its high flexibility… read more here.

Keywords: based normalized; calibration method; method; normalized homography ... See more keywords
Photo by joelfilip from unsplash

A calibration method for fringe reflection technique based on the analytical phase–slope description

Sign Up to like & get
recommendations!
Published in 2018 at "Optics Communications"

DOI: 10.1016/j.optcom.2017.12.046

Abstract: Abstract The fringe reflection technique (FRT) has been one of the most popular methods to measure the shape of specular surface these years. The existing system calibration methods of FRT usually contain two parts, which… read more here.

Keywords: calibration method; calibration; geometric calibration; fringe reflection ... See more keywords
Photo from wikipedia

Whole-field high precision point to point calibration method

Sign Up to like & get
recommendations!
Published in 2018 at "Optics and Lasers in Engineering"

DOI: 10.1016/j.optlaseng.2018.07.005

Abstract: Abstract The traditional camera calibration methods based on internal parameters and external parameters employ a uniform analytic function to meet the requirements of statistical optimization. It may fail in describing the whole measurement volume properly… read more here.

Keywords: calibration method; whole field; point point; point ... See more keywords
Photo from wikipedia

A mineral formula-based calibration method for major and trace element determination of mica without applying an internal element by LA-ICP-MS

Sign Up to like & get
recommendations!
Published in 2023 at "Journal of Analytical Atomic Spectrometry"

DOI: 10.1039/d3ja00026e

Abstract: An internal standard as ablation yield is required to calibrate raw data by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) technology. In this study, we established a new calibration method based... read more here.

Keywords: calibration method; mineral formula; formula based; element ... See more keywords
Photo by kommumikation from unsplash

High Precision Mix‐Signal Capacitor Mismatch Error Calibration Method for Charge‐Domain Pipelined ADC

Sign Up to like & get
recommendations!
Published in 2019 at "Chinese Journal of Electronics"

DOI: 10.1049/cje.2019.01.008

Abstract: A mix-signal high precision capacitor mismatch error calibration method for charge domain pipelined ADCs is proposed. The calibration method calibrates the capacitors one by one based on binary search. Charge errors caused by the capacitor… read more here.

Keywords: calibration; domain pipelined; capacitor mismatch; calibration method ... See more keywords