Articles with "calibration transfer" as a keyword



Photo by varietou from unsplash

Proximal methods for calibration transfer

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Chemometrics"

DOI: 10.1002/cem.2877

Abstract: Calibration transfer (CT) is the process of transferring a calibration curve from one instrument to another or from one set of conditions to another. Direct standardization (DS) of the spectra from a source to a… read more here.

Keywords: instrument; methods calibration; calibration transfer; proximal methods ... See more keywords
Photo from wikipedia

A procedure for calibration transfer of DOSY NMR measurements: An example of molecular weight of heparin preparations

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Chemometrics"

DOI: 10.1002/cem.3210

Abstract: Calibration transfer is commonly used for spectra obtained on different spectrometers or other conditions. This paper reports a multivariate transfer approach for 2D diffusion‐ordered spectroscopy (DOSY) measurements among high‐resolution nuclear magnetic resonance (NMR) spectrometers on… read more here.

Keywords: weight heparin; molecular weight; calibration transfer;
Photo from wikipedia

A calibration transfer methodology for Standardization of Raman instruments with different spectral resolutions using Double Digital Projection Slit

Sign Up to like & get
recommendations!
Published in 2019 at "Chemometrics and Intelligent Laboratory Systems"

DOI: 10.1016/j.chemolab.2019.07.004

Abstract: Abstract A calibration transfer procedure is necessary when the established chemometric models are utilized to predict samples measured on different instruments. However, the existing methods are always ineffective for Raman instruments with different spectral resolution.… read more here.

Keywords: raman instruments; calibration transfer; methodology;
Photo by homajob from unsplash

Chemometrics-assisted calibration transfer strategy for determination of three agrochemicals in environmental samples: Solving signal variation and maintaining second-order advantage

Sign Up to like & get
recommendations!
Published in 2019 at "Chemometrics and Intelligent Laboratory Systems"

DOI: 10.1016/j.chemolab.2019.103869

Abstract: Abstract This manuscript proposes a chemometrics-assisted calibration transfer strategy to determine three agrochemicals (indole-3-acetic acid, 1-naphthylacetic acid and thiabendazole) in environmental samples by excitation-emission matrix (EEM) fluorescence detection. The fluorescence landscapes of target compounds are… read more here.

Keywords: transfer strategy; second order; calibration transfer; environmental samples ... See more keywords
Photo from wikipedia

Calibration transfer of a Raman spectroscopic quantification method for the assessment of liquid detergent compositions from at-line laboratory to in-line industrial scale.

Sign Up to like & get
recommendations!
Published in 2018 at "Talanta"

DOI: 10.1016/j.talanta.2017.11.025

Abstract: Calibration transfer or standardisation aims at creating a uniform spectral response on different spectroscopic instruments or under varying conditions, without requiring a full recalibration for each situation. In the current study, this strategy is applied… read more here.

Keywords: regression; line; calibration transfer; calibration ... See more keywords
Photo from wikipedia

Refining transfer set in calibration transfer of near infrared spectra by backward refinement of samples

Sign Up to like & get
recommendations!
Published in 2020 at "Analytical Methods"

DOI: 10.1039/d0ay00085j

Abstract: The transfer set in calibration transfer can be further refined using a backward refinement (BR) method. Our BR includes many loops, and in each the sample can be removed which reduces the root mean square… read more here.

Keywords: set calibration; transfer set; calibration transfer; transfer ... See more keywords