Sign Up to like & get
recommendations!
0
Published in 2020 at "PROTEOMICS"
DOI: 10.1002/pmic.202000116
Abstract: Analysis of tyrosine kinase signaling is critical for the development of targeted cancer therapy. Currently, immunoprecipitation of phosphotyrosine (pY) peptides prior to liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) is used to profile tyrosine kinase substrates. A…
read more here.
Keywords:
sample;
kinase signaling;
sample requirements;
calibrator ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "Physica Medica"
DOI: 10.1016/j.ejmp.2018.06.218
Abstract: Purpose It is desirable to achieve accurate quantification in PET/CT imaging as routinely assessed using SUV measurement, including for Gallium-68 (68Ga) labelled tracers. A PET/CT scan of a uniformly filled 68Ga phantom on a GE…
read more here.
Keywords:
using default;
measurement;
calibrator;
quantification ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Measurement"
DOI: 10.1016/j.measurement.2017.02.052
Abstract: Abstract An accurate inter-laboratory comparison (ILC) concerning the electrical quantities in low frequency between the laboratory for the calibration of multifunction electrical instruments of the National Institute of Metrology Research (INRIM) and a secondary high…
read more here.
Keywords:
calibrator;
calibration;
laboratory;
comparison ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2018 at "Physics in medicine and biology"
DOI: 10.1088/1361-6560/aadb3b
Abstract: A new class of dose calibrator called a micro-dose calibrator, designed to measure radioactivity rates in the range between 1 kBq up to 370 kBq, has been designed and an 8 NaI(Tl)/photo multiplier tube (PMT)…
read more here.
Keywords:
dose calibrator;
performance;
calibrator;
micro dose ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2022 at "Laboratory medicine"
DOI: 10.1093/labmed/lmac137
Abstract: OBJECTIVE The main concern about measuring the concentration of rivaroxaban by anti-Xa assay in some laboratories is the lack of a commercial specific calibrator in emergencies. Therefore, this study aimed at providing a homemade anti-Xa…
read more here.
Keywords:
anti calibrator;
commercial low;
concentration;
commercial specific ... See more keywords
Sign Up to like & get
recommendations!
2
Published in 2022 at "Micromachines"
DOI: 10.3390/mi13101607
Abstract: The calibrator is one of the most important factors in the calibration of various laser 3D scanning instruments. The requirements for the diffuse reflection surface are emphasized in many national standards. In this study, spherical…
read more here.
Keywords:
calibrator reflectance;
standard;
plane;
reflectance ... See more keywords