Articles with "cbct" as a keyword



Photo from wikipedia

Assessment of the accuracy and stability of frameless gamma knife radiosurgery

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.12365

Abstract: Abstract The aim of this study was to assess the accuracy and stability of frameless gamma knife radiosurgery (GKRS). The accuracies of the radiation isocenter and patient couch movement were evaluated by film dosimetry with… read more here.

Keywords: accuracy; frameless; gamma knife; cbct ... See more keywords
Photo from wikipedia

A feasibility study of intrafractional tumor motion estimation based on 4D‐CBCT using diaphragm as surrogate

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.12410

Abstract: Abstract Purpose To investigate the intrafractional stability of the motion relationship between the diaphragm and tumor, as well as the feasibility of using diaphragm motion to estimate lung tumor motion. Methods Eighty‐five paired (pre and… read more here.

Keywords: motion; image; estimation; position ... See more keywords
Photo from wikipedia

Quantifying the accuracy of deformable image registration for cone‐beam computed tomography with a physical phantom

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.12717

Abstract: Abstract Purpose Kilo‐voltage cone‐beam computed tomography (CBCT) is widely used for patient alignment, contour propagation, and adaptive treatment planning in radiation therapy. In this study, we evaluated the accuracy of deformable image registration (DIR) for… read more here.

Keywords: image; phantom; image registration; accuracy ... See more keywords
Photo from wikipedia

How does CBCT reconstruction algorithm impact on deformably mapped targets and accumulated dose distributions?

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.13328

Abstract: Abstract Purpose We performed quantitative analysis of differences in deformable image registration (DIR) and deformable dose accumulation (DDA) computed on CBCT datasets reconstructed using the standard (Feldkamp‐Davis‐Kress: FDK_CBCT) and a novel iterative (iterative_CBCT) CBCT reconstruction… read more here.

Keywords: dose distributions; fdk cbct; cbct reconstruction; cbct ... See more keywords
Photo by argyriou from unsplash

MVCT versus kV‐CBCT for targets subject to respiratory motion: A phantom study

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.13356

Abstract: Abstract The use of kilovoltage cone‐beam computed tomography (kV‐CBCT) or megavoltage computed tomography (MVCT) for image guidance prior to lung stereotactic body radiation therapy (SBRT) is common clinical practice. We demonstrate that under equivalent respiratory… read more here.

Keywords: motion; mvct; target; cbct ... See more keywords
Photo from wikipedia

Comparison of an in‐house hybrid DIR method to NiftyReg on CBCT and CT images for head and neck cancer

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.13540

Abstract: Abstract An in‐house hybrid deformable image registration (DIR) method, which combines free‐form deformation (FFD) and the viscous fluid registration method, is proposed. Its results on the planning computed tomography (CT) and the day 1 treatment… read more here.

Keywords: dir method; house hybrid; method; proposed method ... See more keywords
Photo from wikipedia

Assessment of CBCT–based synthetic CT generation accuracy for adaptive radiotherapy planning

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.13737

Abstract: Abstract Purpose Cone‐beam CT (CBCT)–based synthetic CT (sCT) dose calculation has the potential to make the adaptive radiotherapy (ART) pathway more efficient while removing subjectivity. This study assessed four sCT generation methods using 15 head‐and‐neck… read more here.

Keywords: cbct; generation; adaptive radiotherapy; cbct based ... See more keywords
Photo from wikipedia

Artifact removal for unpaired thorax CBCT images using a feature fusion residual network and contextual loss.

Sign Up to like & get
recommendations!
Published in 2023 at "Journal of applied clinical medical physics"

DOI: 10.1002/acm2.13968

Abstract: BACKGROUND AND OBJECTIVE Cone-beam computed tomography (CBCT) has become a more and more active cutting-edge topic in the international computed tomography (CT) research due to its advantages of fast scanning speed, high ray utilization rate… read more here.

Keywords: cbct images; feature fusion; loss; thorax cbct ... See more keywords
Photo from wikipedia

Current status of cone-beam computed tomography teaching in Brazilian undergraduate endodontic programs - A web-based survey.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of dental education"

DOI: 10.1002/jdd.13123

Abstract: PURPOSES This study aimed to assess the current status of cone-beam computed tomography (CBCT) education in Brazilian undergraduate Endodontic programs. METHODS One hundred program directors were emailed. The questionnaire asked whether the CBCT topic was… read more here.

Keywords: topic; program; status cone; inclusion ... See more keywords
Photo by accuray from unsplash

Diagnostic value of CBCT in Chinese children with adenoid hypertrophy

Sign Up to like & get
recommendations!
Published in 2022 at "Laryngoscope Investigative Otolaryngology"

DOI: 10.1002/lio2.837

Abstract: The main objectives of the study were to investigate the reliability and accuracy of cone‐beam computed tomography (CBCT) in the diagnosis of adenoid hypertrophy in Chinese children and to evaluate its value in clinical diagnosis. read more here.

Keywords: diagnostic value; adenoid hypertrophy; cbct; chinese children ... See more keywords
Photo from wikipedia

Fast shading correction for cone beam CT in radiation therapy via sparse sampling on planning CT

Sign Up to like & get
recommendations!
Published in 2017 at "Medical Physics"

DOI: 10.1002/mp.12190

Abstract: Purpose The image quality of cone beam computed tomography (CBCT) is limited by severe shading artifacts, hindering its quantitative applications in radiation therapy. In this work, we propose an image‐domain shading correction method using planning… read more here.

Keywords: sparse sampling; radiation therapy; shading correction; correction ... See more keywords