Articles with "cmia" as a keyword



Clinical trial and performance evaluation of the Wantai HBsAg (CMIA) diagnostic kit for screening blood donors in China

Sign Up to like & get
recommendations!
Published in 2024 at "Scientific Reports"

DOI: 10.1038/s41598-024-51910-1

Abstract: In China, according to the ‘Technical Operating Procedures for Blood Stations (2019 Edition),’ blood stations are authorized to utilize Chemiluminescence Immunoassay (CLIA) to detect pathogen markers linked with transfusion-transmissible infections. However, currently, there is no… read more here.

Keywords: wantai; elisa; performance; blood ... See more keywords

Analytical and clinical performance evaluation of the Wantai chemiluminescence microparticle immunoassay on the Wan200 + analyzer for diagnosing HIV

Sign Up to like & get
recommendations!
Published in 2025 at "Scientific Reports"

DOI: 10.1038/s41598-025-03077-6

Abstract: On September 1, 2019, China implemented the “Blood Station Technical Operation Procedures (2019 Edition),” specifying Enzyme-Linked Immunosorbent Assay (ELISA) and Chemiluminescent Immunoassay (CLIA) for serological testing. However, no CLIA HIV reagent has been approved for… read more here.

Keywords: detection; hiv; cmia elisa; blood ... See more keywords

Challenged comparison of tacrolimus assays.

Sign Up to like & get
recommendations!
Published in 2022 at "Scandinavian journal of clinical and laboratory investigation"

DOI: 10.1080/00365513.2022.2056858

Abstract: Monitoring tacrolimus trough concentrations is important for optimal immunosuppression in solid organ transplant recipients. Available assays generally correlate well with each other but little attention is given to patients in whom tacrolimus metabolite concentrations might… read more here.

Keywords: lcms assays; cmia; bias; tacrolimus ... See more keywords

Good correlation between tacrolimus concentrations using improved CMIA on the Alinity i analyzer and LC-MS/MS method from a reference laboratory but unexpected negative bias with another LC-MS/MS method from a different reference laboratory.

Sign Up to like & get
recommendations!
Published in 2024 at "American journal of clinical pathology"

DOI: 10.1093/ajcp/aqae005

Abstract: OBJECTIVES We compared tacrolimus concentrations obtained by the more recently US Food and Drug Administration-approved tacrolimus assay (CMIA) on the Alinity i analyzer (Abbott Laboratories) with a liquid chromatography/tandem mass spectrometry (LC-MS/MS)-based method from 2… read more here.

Keywords: cmia; reference; tacrolimus concentrations; reference laboratory ... See more keywords

Comparison of chemiluminescence microparticle immunoassay, indirect immunofluorescence assay, linear immunoassay and multiple microbead immunoassay detecting autoantibodies in systemic lupus erythematosus

Sign Up to like & get
recommendations!
Published in 2020 at "Scandinavian Journal of Immunology"

DOI: 10.1111/sji.12849

Abstract: The aim of study was to detect antinuclear antibodies (ANA) using indirect immunofluorescence assay (IIFA), linear immunoassay (LIA), chemiluminescence microparticle immunoassay (CMIA), multiple microbead immunoassay (MBI) and to compare these four methods in the performance… read more here.

Keywords: linear immunoassay; indirect immunofluorescence; sle; cmia ... See more keywords

The Anti-SARS-CoV-2 S-Protein IgG, Which Is Detected Using the Chemiluminescence Microparticle Immunoassay (CMIA) in Individuals Having Either a History of COVID-19 Vaccination and/or SARS-CoV-2 Infection, Showed a High-Titer Neutralizing Effect

Sign Up to like & get
recommendations!
Published in 2024 at "Viruses"

DOI: 10.3390/v16091409

Abstract: Neutralizing antibodies plays a primary role in protective immunity by preventing severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) from entering the cells. Therefore, characterization of antiviral immunity is important for protection against SARS-CoV-2. In this study,… read more here.

Keywords: sars cov; titration; history; neutralizing effect ... See more keywords

Clinical Utility of Liquid Chromatography-Tandem Mass Spectrometry for Thyroglobulin Measurement in Comparison with Immunoradiometric Assay and Chemiluminescence Microparticle Immunoassay.

Sign Up to like & get
recommendations!
Published in 2025 at "Endocrinology and metabolism"

DOI: 10.3803/enm.2025.2413

Abstract: Background The liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to overcome interference from thyroglobulin autoantibodies (TgAb); however, it has not yet been implemented in Korea. This study aimed to confirm the accuracy of LC-MS/MS… read more here.

Keywords: tandem mass; mass spectrometry; tgab; cmia ... See more keywords

Performance of the Enzyme Linked Fluorescent Assay in Diagnosis of HIV Infection; Comparative Evaluation with other Methods.

Sign Up to like & get
recommendations!
Published in 2022 at "Clinical laboratory"

DOI: 10.7754/clin.lab.2022.211044

Abstract: BACKGROUND Our study aimed to investigate the role of the enzyme linked fluorescent assay (ELFA) method in the diagnosis of Human Immunodeficiency Virus (HIV) infection by comparing it with enzyme-linked immunosorbent assay (ELISA) and chemiluminescent… read more here.

Keywords: elfa; hiv; enzyme linked; cmia ... See more keywords