Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of Superconductivity and Novel Magnetism"
DOI: 10.1007/s10948-018-4869-3
Abstract: The resistivetype superconducting fault current limiter (R-SFCL) is simple in structure, near zero impedance at normal state and can be quickly triggered by the fault current. Thus, it is a possible solution to limit the…
read more here.
Keywords:
fault;
module;
superconducting fault;
fault current ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Ain Shams Engineering Journal"
DOI: 10.1016/j.asej.2015.08.008
Abstract: Abstract The presence of distributed generation (DG) units in distribution systems increases the fault current level, which disrupts the existing coordination time interval of the protective overcurrent relays. One of the ways for decreasing DG…
read more here.
Keywords:
coordination;
fault current;
current limiter;
unidirectional fault ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2017 at "Cryogenics"
DOI: 10.1016/j.cryogenics.2016.10.004
Abstract: Abstract Recent years, voltage source converter-based multi-terminal high voltage DC power transmission (MTDC) is widely developed in the world. However, it is difficult for the existing DC breaker to cut off the fault transmission line…
read more here.
Keywords:
mtdc system;
fault current;
fault;
current limiter ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2021 at "Cryogenics"
DOI: 10.1016/j.cryogenics.2021.103296
Abstract: Abstract Optimal energy management is a major challenge for most energy storage systems (ESSs), which is especially a big concern for the superconducting fault current limiter-magnetic ESS (SFCL-MES). To prevent malfunction, the superconducting coil (SC)…
read more here.
Keywords:
fault current;
energy storage;
superconducting fault;
current limiter ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2017 at "Electric Power Components and Systems"
DOI: 10.1080/15325008.2017.1405466
Abstract: Abstract This paper presents a method for determining the optimum number, impedance, and locations of fault current limiter (FCL) to reduce the negative impact of distributed generations presence in the power systems such as increasing…
read more here.
Keywords:
objective firework;
multi objective;
fault current;
firework algorithm ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2019 at "Superconductor Science and Technology"
DOI: 10.1088/1361-6668/ab099a
Abstract: Within a German government funded project the partners Siemens AG and KIT have developed an iron-free inductive current limiter. The project aimed at a device for the medium voltage range, i.e. U = 10 kV…
read more here.
Keywords:
reactor coil;
test;
current limiter;
mva ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2020 at "IEEE Access"
DOI: 10.1109/access.2020.3000462
Abstract: Doubly fed induction generators (DFIGs) are vulnerable to grid related electrical faults. Standards require DFIGs to be disconnected from the grid unless augmented with a fault ride through (FRT) capability. A fault current limiter (FCL)…
read more here.
Keywords:
logic controlled;
fault current;
current limiter;
fault ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2021 at "IEEE Access"
DOI: 10.1109/access.2021.3050795
Abstract: With the sustainable growth in the integration of distributed generation units in the distribution network, the probability of the fault current level exceeding the rating of existing components increases. Cascaded H bridge fault current limiter…
read more here.
Keywords:
fault current;
improved bat;
objective improved;
current limiter ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2018.2814398
Abstract: Battery energy storage system (BESS) is required in microgrids to balance the energy requirements from the load and the generated available energy. However, under fault conditions, there are many problems facing BESS. Accordingly, superconducting fault…
read more here.
Keywords:
system;
superconducting fault;
fault current;
battery ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2019 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2019.2911305
Abstract: There are many disadvantages in the conventional method of limiting the short-circuit of the flexible HVdc transmission system such as a series-connecting electric reactor on the dc side. This paper presents a short-circuit current limiting…
read more here.
Keywords:
current limiter;
fault current;
system;
superconducting fault ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2020 at "IEEE Transactions on Applied Superconductivity"
DOI: 10.1109/tasc.2019.2963410
Abstract: A resistive-type dc superconducting fault current limiter (SFCL) is developed for the fault current limiting at the Suzhou Nami substation. The rated voltage and current are 20 kV and 400 A, respectively. The prospective peak…
read more here.
Keywords:
fault current;
superconducting fault;
test;
current limiter ... See more keywords