Articles with "cusp overlap" as a keyword



Cusp‐overlap versus coplanar view in transcatheter aortic valve implantation with self‐expandable valves: A meta‐analysis of comparative studies

Sign Up to like & get
recommendations!
Published in 2023 at "Catheterization and Cardiovascular Interventions"

DOI: 10.1002/ccd.30562

Abstract: Permanent pacemaker implantation (PPI) is a common complication after transcatheter aortic valve implantation (TAVI). The cusp‐overlap view (COV) was adopted to reduce PPI risk after TAVI with self‐expandable valves (SEVs); however, the evidence remains scarce.… read more here.

Keywords: view; aortic valve; cusp overlap; valve implantation ... See more keywords

Predictors of permanent pacemaker implantation for transcatheter self‐expandable aortic valve implant in the cusp overlap era

Sign Up to like & get
recommendations!
Published in 2024 at "Catheterization and Cardiovascular Interventions"

DOI: 10.1002/ccd.31176

Abstract: Predictors of permanent pacemaker implantation (PPMI) after self‐expanding transcatheter aortic valve implant (TAVI) were described. Is unknown if PPMI predictors remain in the era of high implants using the cusp overlap (COP). read more here.

Keywords: valve implant; predictors permanent; aortic valve; cusp overlap ... See more keywords

Abstract 4143899: cusp-overlap view versus three cusp coplanar view during transcatheter aortic valve replacement using self-expandable valves: A meta-analysis of 5947 patients.

Sign Up to like & get
recommendations!
Published in 2024 at "Circulation"

DOI: 10.1161/circ.150.suppl_1.4143899

Abstract: Background & Objectives: Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for most patients with symptomatic severe aortic stenosis. We conducted this systematic review, and meta-analysis to compare the efficacy and procedural… read more here.

Keywords: view; meta analysis; cot; analysis ... See more keywords

Real-world experience with the cusp-overlap deployment technique in transcatheter aortic valve replacement: A propensity-matched analysis

Sign Up to like & get
recommendations!
Published in 2022 at "Frontiers in Cardiovascular Medicine"

DOI: 10.3389/fcvm.2022.847568

Abstract: Background The implantation depth (ID) is a critical condition for optimal hemodynamic and clinical outcomes in transcatheter aortic valve replacement (TAVR). The recently recommended cusp-overlap technique (COT) offers optimized fluoroscopic projections facilitating a precise ID.… read more here.

Keywords: transcatheter aortic; valve replacement; cusp overlap; aortic valve ... See more keywords

Comparison of cusp-overlap projection and standard three-cusp coplanar view during self-expanding transcatheter aortic valve replacement: A systematic review and meta-analysis

Sign Up to like & get
recommendations!
Published in 2022 at "Frontiers in Cardiovascular Medicine"

DOI: 10.3389/fcvm.2022.927642

Abstract: Objective Permanent pacemaker implantation (PPI) is a common complication after transcatheter aortic valve replacement (TAVR). Recently, the cusp-overlap projection (COP) technique was thought to be a feasible method to reduce PPI risk. However, the evidence… read more here.

Keywords: projection; cusp overlap; analysis; overlap projection ... See more keywords