Articles with "czt" as a keyword



Investigation of photoconductivity and electric field distribution in CZT detectors by time-of-flight (TOF) and charge extraction by linearly increasing voltage (CELIV)

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Materials Science: Materials in Electronics"

DOI: 10.1007/s10854-018-9527-9

Abstract: Although cadmium zinc telluride (CZT) is the most widely used room-temperature photoconductor for low flux radiation sensing, utilization of this promising material in high flux applications, like computed tomography is challenging, due to possible dynamic… read more here.

Keywords: czt; time flight; charge; charge extraction ... See more keywords

Study on the Performance of a Planar CdZnTe Detector with Guard-Ring

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Electronic Materials"

DOI: 10.1007/s11664-020-08180-0

Abstract: The guard-ring of a CdZnTe (CZT) detector can reduce surface leakage current and improve charge collection efficiency. In this paper, COMSOL simulation software is adopted to evaluate the influence of the weighting potential and electric… read more here.

Keywords: guard ring; czt; detector guard; cdznte ... See more keywords

Gated SPECT myocardial perfusion imaging with cadmium-zinc-telluride detectors allows real-time assessment of dobutamine-stress-induced wall motion abnormalities

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Nuclear Cardiology"

DOI: 10.1007/s12350-018-1187-x

Abstract: BackgroundLeft ventricular (LV) ejection fraction (EF) during high dobutamine stress (HD) by real-time gated-SPECT myocardial perfusion imaging (MPI) on a cadmium-zinc-telluride (CZT) gamma camera was validated versus cardiac magnetic resonance imaging (CMR).Methods and resultsAfter injecting… read more here.

Keywords: dobutamine; real time; czt; time ... See more keywords

Dynamic ultrafast CZT imaging: Time for a paradigm change in myocardial perfusion imaging

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Nuclear Cardiology"

DOI: 10.1007/s12350-020-02051-1

Abstract: Cardiac stress imaging has been always regarded as the best way for the non-invasive assessment for the presence of significant coronary artery disease (CAD), guiding patients’ risk stratification and clinical management. Accordingly, for over half… read more here.

Keywords: myocardial perfusion; cad; cardiology; accuracy ... See more keywords
Photo by amaitu from unsplash

The current status of CZT SPECT myocardial blood flow and reserve assessment: Tips and tricks

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Nuclear Cardiology"

DOI: 10.1007/s12350-021-02620-y

Abstract: Cardiac PET-derived measurements of myocardial blood flow (MBF) and myocardial flow reserve (MFR) are proven robust indexes of the severity of coronary artery disease (CAD). They facilitate the diagnosis of diffuse epicardial and microvascular disease… read more here.

Keywords: blood flow; czt; flow reserve; myocardial blood ... See more keywords

Radiation measurement and imaging using 3D position sensitive pixelated CZT detector

Sign Up to like & get
recommendations!
Published in 2019 at "Nuclear Engineering and Technology"

DOI: 10.1016/j.net.2019.03.009

Abstract: Abstract In this study, we evaluated the performance of a commercial pixelated cadmium zinc telluride (CZT) detector for spectroscopy and identified its feasibility as a Compton camera for radiation monitoring in a nuclear power plant.… read more here.

Keywords: czt; radiation measurement; czt detector; position ... See more keywords

Development and comparative evaluation of two immunoassay platforms for bioanalysis of crizotinib: A potent drug used for the treatment of non-small cell lung cancer.

Sign Up to like & get
recommendations!
Published in 2019 at "Talanta"

DOI: 10.1016/j.talanta.2019.04.013

Abstract: This study describes, for the first time, the development of two platforms of competitive fluorescent immunoassays for bioanalysis of crizotinib (CZT), a potent drug used for the treatment of non-small cell lung cancer (NSCLC). These… read more here.

Keywords: czt; kinexa; drug; drug used ... See more keywords

Experimental, theoretical and numerical simulation-based investigations on the fabricated Cu2ZnSn thin-film-based Schottky diodes with enhanced electron transport for solar cell

Sign Up to like & get
recommendations!
Published in 2024 at "Scientific Reports"

DOI: 10.1038/s41598-024-63857-4

Abstract: Copper-zinc-tin Cu2ZnSn (CZT) thin films are promising materials for solar cell applications. This thin film was deposited on a fluorine-doped tin oxide (FTO) using an electrochemical deposition hierarchy. X-ray diffraction of thin-film studies confirms the… read more here.

Keywords: czt thin; thin films; simulation; thin film ... See more keywords

Characterisation of Redlen HF-CdZnTe at > 106 ph s-1 mm-2 using HEXITECMHz

Sign Up to like & get
recommendations!
Published in 2024 at "Journal of Instrumentation"

DOI: 10.1088/1748-0221/19/04/p04028

Abstract: In this paper, results are presented from the characterisation of Redlen Technologies high-flux-capable Cadmium Zinc Telluride (HF-CZT) hybridised to the HEXITECMHz ASIC, a novel 1 MHz continuous X-ray imaging system. A 2 mm thick HF-CZT… read more here.

Keywords: cdznte 106; characterisation redlen; 106 using; redlen cdznte ... See more keywords

Simultaneous dual-isotope solid-state detector SPECT for improved tracking of white blood cells in suspected endocarditis

Sign Up to like & get
recommendations!
Published in 2017 at "European Heart Journal"

DOI: 10.1093/eurheartj/ehw231

Abstract: Aims High-energy resolution and sensitivity of novel cadmium-zinc-telluride (CZT) detector equipped SPECT systems facilitate simultaneous imaging of multiple isotopes and may enhance the detection of molecular/cellular signals. This may refine the detection of endocarditis. This… read more here.

Keywords: dual isotope; spect; white blood; czt ... See more keywords

Evaluation of biventricular function by cadmium–zinc–telluride SPECT gated tomographic radionuclide angiography: Comparison to conventional SPECT

Sign Up to like & get
recommendations!
Published in 2024 at "Medicine"

DOI: 10.1097/md.0000000000039821

Abstract: We compared and analyzed the consistency and repeatability of left and right ventricular ((LV/RV) functions obtained by gated-equilibrium radionuclide ventriculography (ERNV) with cadmium–zinc–telluride single-photon emission computed tomography (CZT-SPECT) and conventional SPECT (C-SPECT) with sodium iodide… read more here.

Keywords: czt spect; rvef; function; evaluation biventricular ... See more keywords