Sign Up to like & get
recommendations!
1
Published in 2018 at "Multimedia Tools and Applications"
DOI: 10.1007/s11042-018-6453-z
Abstract: In this paper, a structural local DCT sparse appearance model with occlusion detection is proposed for visual tracking in a particle filter framework. The energy compaction property of the 2D-DCT is exploited to reduce the…
read more here.
Keywords:
appearance model;
occlusion;
occlusion detection;
dct ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2018 at "Multimedia Tools and Applications"
DOI: 10.1007/s11042-018-6505-4
Abstract: A blind watermarking algorithm is proposed, which is based on the Discrete Cosine Transform (DCT) method. It uses Two-Dimensional Linear Discriminant Analysis (2DLDA) watermark scheme for copyright protection. During the embedding process, the color image…
read more here.
Keywords:
watermark;
color;
image;
method ... See more keywords
Photo by usgs from unsplash
Sign Up to like & get
recommendations!
0
Published in 2019 at "Multidimensional Systems and Signal Processing"
DOI: 10.1007/s11045-018-0601-5
Abstract: The principal component analysis (PCA) is widely used for data decorrelation and dimensionality reduction. However, the use of PCA may be impractical in real-time applications, or in situations were energy and computing constraints are severe.…
read more here.
Keywords:
image;
complexity;
dct;
image video ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of Real-Time Image Processing"
DOI: 10.1007/s11554-019-00918-2
Abstract: A low-complexity pruned eight-point discrete cosine transform (DCT) approximation for image compression in visual sensor networks is introduced. The proposed transform consists of using an approximate DCT in combination with pruning approach. The aim of…
read more here.
Keywords:
image;
visual sensor;
sensor networks;
dct ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2021 at "International Journal of Engineering Science"
DOI: 10.1016/j.ijengsci.2021.103521
Abstract: Abstract Deep cryogenic treatment (DCT) has been known since the 1930s to improve hardness, fatigue resistance, and wear resistance of steel. While the effect of DCT on wear properties has been well documented, there is…
read more here.
Keywords:
steel;
dct;
effect;
deep cryogenic ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2017 at "Engineering Science and Technology, an International Journal"
DOI: 10.1016/j.jestch.2016.07.002
Abstract: Abstract In this paper, an interpolation method based on discrete cosine transform (DCT) is employed for digital finite impulse response-fractional order differentiator (FIR-FOD) design. Here, a fractional order digital differentiator is modeled as finite impulse…
read more here.
Keywords:
differentiator;
fractional order;
dct;
interpolation ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2021 at "Journal of materials research and technology"
DOI: 10.1016/j.jmrt.2021.07.022
Abstract: Abstract In recent years, promising technique of deep cryogenic treatment (DCT) is taking a new step in improving properties of various materials, especially steels. This study is focusing on influence of selected heat treatment process…
read more here.
Keywords:
steel;
treatment;
heat treatment;
dct ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2021 at "Kidney international"
DOI: 10.1016/j.kint.2021.06.030
Abstract: Adverse effects of calcineurin inhibitors (CNI), such as hypertension, hyperkalemia, acidosis, hypomagnesemia and hypercalciuria, have been linked to dysfunction of the distal convoluted tubule (DCT). To test this, we generated a mouse model with an…
read more here.
Keywords:
acidosis;
calcineurin;
distal convoluted;
cnb1 mice ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2022 at "Journal of Glaucoma"
DOI: 10.1097/ijg.0000000000002023
Abstract: PrĂ©cis: All devices evaluated in this study showed a significant underestimation in intraocular pressure (IOP) measurement after myopic photorefractive keratectomy (PRK), Goldmann tonometer more than others. Corneal biomechanics indicated a different influence on the different…
read more here.
Keywords:
myopic;
prk;
intraocular pressure;
cst ... See more keywords
Sign Up to like & get
recommendations!
3
Published in 2022 at "IEEE Access"
DOI: 10.1109/access.2022.3146162
Abstract: This paper proposes an effective hardware accelerator for 2D $8\times 8$ discrete cosine transform (DCT) and inverse discrete cosine transform (IDCT) using an improved Loeffler architecture. The accelerator optimizes the data stream of the Loeffler…
read more here.
Keywords:
dct idct;
architecture;
dct;
hardware accelerator ... See more keywords
Photo by usgs from unsplash
Sign Up to like & get
recommendations!
2
Published in 2022 at "IEEE Access"
DOI: 10.1109/access.2022.3192416
Abstract: An innovative image enhancement and feature extraction technique that is based on the modified sigmoid function and two-dimensional DCT has been developed. The proposed technique uses a modified sigmoid function that accommodates the original microscopic…
read more here.
Keywords:
sigmoid function;
dct;
image;
microscopic images ... See more keywords