Sign Up to like & get
recommendations!
0
Published in 2019 at "Journal of the mechanical behavior of biomedical materials"
DOI: 10.1016/j.jmbbm.2018.12.006
Abstract: PURPOSE The purpose of this systematic review was to investigate the effect of reinforcement on the mechanical behaviour of implant overdenture (IOD) bases and its cumulative biological effect on the underlying supporting structures (implants and…
read more here.
Keywords:
denture base;
systematic review;
reinforcement;
residual ridge ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Journal of prosthodontic research"
DOI: 10.1016/j.jpor.2016.04.006
Abstract: PURPOSE This study evaluated the shear bond strength of a chairside autopolymerizing reline resin to injection-molded thermoplastic denture base resins. METHODS Four kinds of injection-molded thermoplastic resins (two polyamides, a polyethylene terephthalate copolymer and a…
read more here.
Keywords:
resin;
injection molded;
bond;
molded thermoplastic ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2019 at "Journal of prosthodontic research"
DOI: 10.1016/j.jpor.2019.10.008
Abstract: PURPOSE The purpose of this study was to compare the adhesiveness of chewing gum to hard and soft denture base materials to investigate food retention associated with the basal surface of the denture. METHODS Test…
read more here.
Keywords:
dry conditions;
chewing gum;
denture;
base materials ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "Scientific Reports"
DOI: 10.1038/s41598-024-51486-w
Abstract: Various materials have been introduced for the three-dimensional (3D) printing of dentures. In this study, the color stability and surface and physicochemical properties of 3D-printed denture base resins with four types of nanofiller particles were…
read more here.
Keywords:
stability;
denture base;
color stability;
group ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "Scientific Reports"
DOI: 10.1038/s41598-024-54408-y
Abstract: For patients who have difficulty in mechanical cleaning of dental appliances, a denture cleaner that can remove biofilm with dense extracellular polymeric substances is needed. The purpose of this study is to evaluate the efficacy…
read more here.
Keywords:
denture base;
biofilm removal;
base resin;
diatom complex ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Scientific Reports"
DOI: 10.1038/s41598-025-01685-w
Abstract: The aim of this study was to compare the performance of denture base materials produced by three-dimensional (3D) printing and conventional methods in terms of their mechanical durability and water absorption and solubility properties. Conventional…
read more here.
Keywords:
denture base;
denture;
durability;
performance ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Scientific Reports"
DOI: 10.1038/s41598-025-24596-2
Abstract: This study evaluated the shear bond strength (SBS), flexural strength, and color stability of three denture base resins (DBRs)—heat-polymerized (HEA), cold-polymerized (COL), and 3D-printed (TDP)—before and after thermocycling. SBS was evaluated after bonding COL to…
read more here.
Keywords:
denture base;
flexural strength;
hea;
col ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2019 at "European Journal of Dentistry"
DOI: 10.1055/s-0039-1688533
Abstract: Objective This study aimed to assess the effect of reinforcement, denture base thickness, and acrylic resin types on dynamic and static fracture strength in mandibular implant overdentures with bar attachment. Materials and Methods One hundred…
read more here.
Keywords:
resin;
denture base;
fracture strength;
fracture ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2022 at "European Journal of Dentistry"
DOI: 10.1055/s-0042-1749160
Abstract: Abstract Objectives This study aimed to evaluate the influence of different salivary pH on flexural strength, hardness, and surface roughness of computer-aided design and computer-aided manufacturing (CAD/CAM) milled and three-dimensional (3D)-printed denture base resins. Methods…
read more here.
Keywords:
strength;
denture base;
surface;
flexural strength ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "Materials Research Express"
DOI: 10.1088/2053-1591/ad64b0
Abstract: Objectives. The present work investigates the influence of pulsed nanosecond laser patterning of two commercial heat cure poly (methyl methacrylate) denture base materials, Trevalon and DPI heat cure, on their surface characteristics such as roughness,…
read more here.
Keywords:
denture base;
microbial adhesion;
base materials;
surface ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2017 at "Journal of Prosthodontics"
DOI: 10.1111/jopr.12419
Abstract: PURPOSE To evaluate the effect of reinforcement on the flexural properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS Three injection-molded thermoplastic denture base resins (polyamide, polyester, polycarbonate) were selected for this study, and…
read more here.
Keywords:
thermoplastic denture;
injection molded;
molded thermoplastic;
denture ... See more keywords