Articles with "dialyzer" as a keyword



Photo from wikipedia

Anticoagulant dialyzer with enhanced Ca2+ chelation and hydrophilicity for heparin free hemodialysis

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Membrane Science"

DOI: 10.1016/j.memsci.2020.118082

Abstract: Abstract Inhibiting thrombosis in extracorporeal dialyzer is predominantly determined by the compatible interface design. It is challenging to develop anticoagulant dialyzers for clinical heparin free dialysis. Herein, we develop an environmentally friendly approach to construct… read more here.

Keywords: heparin free; ca2 chelation; anticoagulant dialyzer; dialyzer ... See more keywords
Photo by curology from unsplash

P1078IMPACT OF A MEDIUM CUT-OFF DIALYZER ON SKIN AUTOFLUORESCENCE IN HAEMODIALYSIS PATIENTS

Sign Up to like & get
recommendations!
Published in 2020 at "Nephrology Dialysis Transplantation"

DOI: 10.1093/ndt/gfaa142.p1078

Abstract: Introduction: Advanced glycation end-products (AGEs) are middle-sized uraemic toxins that accumulate in haemodialysis (HD) patients due to increased production, impaired excretion and insufficient removal. Previous studies have reported that the use of a medium cut-off… read more here.

Keywords: haemodialysis patients; skin autofluorescence; medium cut; dialyzer ... See more keywords
Photo from wikipedia

P1103A RANDOMIZED CONTROLLED STUDY ON THE DIALYZERS WITH CELLULOSE TRIACETATE MEMBRANE AND WITH POLYSULFONE MEMBRANE FOR MAINTENANCE HEMODIALYSIS PATIENTS

Sign Up to like & get
recommendations!
Published in 2020 at "Nephrology Dialysis Transplantation"

DOI: 10.1093/ndt/gfaa142.p1103

Abstract: With the continuous development and optimization of dialysis membrane materials, polysulfone (PS) as the third generation of dialysis membrane has replaced cellulose triacetate (CTA) and dominated the market because of its better biocompatibility. However, we… read more here.

Keywords: cta dialyzer; two groups; group; dialyzer ... See more keywords
Photo by charlesdeluvio from unsplash

Choosing a dialyzer: What clinicians need to know

Sign Up to like & get
recommendations!
Published in 2018 at "Hemodialysis International"

DOI: 10.1111/hdi.12702

Abstract: The objectives of hemodialysis have moved from the diffusive clearance of small molecular weight uremic toxins and achieving dialyzer urea adequacy targets to emphasis on improving clinical outcomes in end stage renal failure patients by… read more here.

Keywords: dialyzer clinicians; clinicians need; toxin clearance; dialyzer ... See more keywords

Evaluation of the Impact of a New Synthetic Vitamin E-Bonded Membrane on the Hypo-Responsiveness to the Erythropoietin Therapy in Hemodialysis Patients: A Multicenter Study

Sign Up to like & get
recommendations!
Published in 2017 at "Blood Purification"

DOI: 10.1159/000453442

Abstract: Background: Oxidative stress has been related to hypo-response to erythropoiesis-stimulating agents (ESAs) in hemodialysis (HD) patients. The aim of this study was to verify whether vitamin E (ViE) on a synthetic polysulfone dialyzer can improve… read more here.

Keywords: multicenter study; dialyzer; hemodialysis patients; responsiveness ... See more keywords
Photo from wikipedia

Comparative Effectiveness between Expanded Hemodialysis (Hemodialysis Using a Medium Cut-Off Dialyzer) and Mixed-Dilution Online Hemodiafiltration Using a High-Flux Dialyzer in Removing Middle-Molecule Uremic Toxins

Sign Up to like & get
recommendations!
Published in 2022 at "Blood Purification"

DOI: 10.1159/000521886

Abstract: Introduction: Expanded hemodialysis (HD using a medium cut-off dialyzer [HD + MCO]) provides comparable or better removal of various uremic toxins, particularly large middle-molecule uremic toxins, than post-dilution online hemodiafiltration (olHDF). Uremic toxin-removing effectiveness between… read more here.

Keywords: mixed dilution; dilution; hemodialysis; middle molecule ... See more keywords
Photo by igormiske from unsplash

Efficacy and Safety of the Medium Cut-Off Elisio HX Dialyzer

Sign Up to like & get
recommendations!
Published in 2022 at "Blood Purification"

DOI: 10.1159/000524644

Abstract: Introduction: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy… read more here.

Keywords: efficacy; cut elisio; hdf; medium cut ... See more keywords
Photo by rgaleriacom from unsplash

Polymethylmethacrylate Membrane Dialyzer: Historic but Modern

Sign Up to like & get
recommendations!
Published in 2022 at "Blood Purification"

DOI: 10.1159/000526996

Abstract: Polymethylmethacrylate (PMMA) hollow fiber membranes are one of the synthetic polymer hollow fiber membranes used to the hollow fiber artificial kidney. A PMMA hollow fiber membrane (PMMA membrane) has unique properties including the uniform structure… read more here.

Keywords: membrane; filtryzer; polymethylmethacrylate; hollow fiber ... See more keywords
Photo by videoqueenstl from unsplash

Efeitos clínicos e microbiológicos do reúso de dialisadores em pacientes em hemodiálise

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Biomedical Nanotechnology"

DOI: 10.1590/2175-8239-jbn-2018-0151

Abstract: INTRODUCTION Chronic kidney disease (CKD) has a high prevalence and is a worldwide public health problem. Reuse of dialyzers is a cost reduction strategy used in many countries. There is controversy over its effects on… read more here.

Keywords: dialyzer; nicos microbiol; single use; microbiol gicos ... See more keywords