Articles with "digital tomosynthesis" as a keyword



Photo from wikipedia

Prevalence and distribution of sesamoid bones and accessory ossicles of the foot as determined by digital tomosynthesis

Sign Up to like & get
recommendations!
Published in 2017 at "Clinical Anatomy"

DOI: 10.1002/ca.22952

Abstract: We previously reported that digital tomosynthesis (DTS) is a reliable tool for evaluating bony structures of the hand. The current study aimed to identify the prevalence and distribution of sesamoid bones and accessory ossicles of… read more here.

Keywords: accessory ossicles; bones accessory; sesamoid bones; digital tomosynthesis ... See more keywords
Photo by dawson2406 from unsplash

Effect of View, Scan Orientation and Analysis Volume on Digital Tomosynthesis (DTS) Based Textural Analysis of Bone

Sign Up to like & get
recommendations!
Published in 2017 at "Annals of Biomedical Engineering"

DOI: 10.1007/s10439-017-1792-x

Abstract: Digital tomosynthesis (DTS) derived textural parameters of human vertebral cancellous bone have been previously correlated to the finite element (FE) stiffness and 3D microstructure. The objective of this study was to optimize scanning configuration and… read more here.

Keywords: orientation; tomosynthesis dts; analysis; bone ... See more keywords
Photo by usgs from unsplash

Image reconstruction in region-of-interest (or interior) digital tomosynthesis (DTS) based on compressed-sensing (CS)

Sign Up to like & get
recommendations!
Published in 2017 at "Computer methods and programs in biomedicine"

DOI: 10.1016/j.cmpb.2017.08.022

Abstract: BACKGROUND AND OBJECTIVE Digital tomosynthesis (DTS) based on filtered-backprojection (FBP) reconstruction requires a full field-of-view (FOV) scan and relatively dense projections, which results in high doses for medical imaging purposes. To overcome these difficulties, we… read more here.

Keywords: reconstruction; roi dts; image; tomosynthesis dts ... See more keywords
Photo by brnkd from unsplash

Scout-view assisted interior digital tomosynthesis (iDTS) based on compressed-sensing theory

Sign Up to like & get
recommendations!
Published in 2017 at "Radiation Physics and Chemistry"

DOI: 10.1016/j.radphyschem.2017.06.003

Abstract: Abstract Conventional digital tomosynthesis (DTS) based on the filtered-backprojection (FBP) reconstruction requires full field-of-view scan and also relatively dense projections, which results in still high dose for medical imaging purposes. In this work, to overcome… read more here.

Keywords: view; view assisted; scout view; assisted interior ... See more keywords
Photo by kmuza from unsplash

Comparison of analytic and iterative digital tomosynthesis reconstructions for thin slab objects

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Instrumentation"

DOI: 10.1088/1748-0221/12/11/c11030

Abstract: For digital x-ray tomosynthesis of thin slab objects, we compare the tomographic imaging performances obtained from the filtered backprojection (FBP) and simultaneous algebraic reconstruction (SART) algorithms. The imaging performance includes the in-plane molulation-transfer function (MTF),… read more here.

Keywords: comparison analytic; analytic iterative; tomosynthesis; thin slab ... See more keywords
Photo from wikipedia

Pediatric Esophageal Foreign Body: Possible Role for Digital Tomosynthesis.

Sign Up to like & get
recommendations!
Published in 2018 at "Pediatric Emergency Care"

DOI: 10.1097/pec.0000000000001517

Abstract: OBJECTIVES Foreign body (FB) ingestion is a common reason for emergency department visits, affecting more than 80,000 children in the United States annually. Whereas most ingested FBs are coins or other radiopaque objects, some are… read more here.

Keywords: digital tomosynthesis; dts; predictive value; foreign body ... See more keywords
Photo by markusspiske from unsplash

"Digital Tomosynthesis" As a Technique for the Evaluation of Endobronchial Stents in Lung Transplant Recipients.

Sign Up to like & get
recommendations!
Published in 2022 at "Transplantation"

DOI: 10.1097/tp.0000000000004248

Abstract: Lung transplant patients often suffer from posttransplant airway pathologies that require placement of endobronchial stents. In addition to surveillance bronchoscopy, patients often undergo radiographic stent evaluations. Chest x-rays are extremely limited in their ability to… read more here.

Keywords: digital tomosynthesis; evaluation; endobronchial stents; lung transplant ... See more keywords
Photo from wikipedia

High Accuracy of Digital Tomosynthesis-Guided Bronchoscopic Biopsy Confirmed by Intraprocedural Computed Tomography

Sign Up to like & get
recommendations!
Published in 2021 at "Respiration"

DOI: 10.1159/000512802

Abstract: Background: Digital fluoroscopic tomosynthesis-guided electromagnetic navigational bronchoscopy (F-ENB) is a novel adjunct to ENB associated with higher diagnostic yield. The likelihood of F-ENB allowing accurate placement of a biopsy needle within a target remains unclear.… read more here.

Keywords: biopsy; computed tomography; tomosynthesis; nodule ... See more keywords