Anatomical Basis of the Intermediate Dorsal Pedal Neurocutaneous Perforator Pedicled Propeller Flap: A Cadaveric Dissection

Sign Up to like & get
recommendations!
Published in 2018 at "Clinical Anatomy"

DOI: 10.1002/ca.23229

Abstract: Soft tissue defects of the forefoot represent a challenging surgical modality to reconstructive microsurgeons. This study describes the anatomical basis and design of the perforator‐based intermediate dorsal pedal neurocutaneous vascular flap. Thirty fresh human lower… read more here.

Keywords: flap; perforator; anatomy; intermediate dorsal ... See more keywords
Photo by strong18philip from unsplash

Frequency‐dependent layer‐specific differences in short‐term synaptic plasticity in the dorsal and ventral CA1 hippocampal field

Sign Up to like & get
recommendations!
Published in 2021 at "Synapse"

DOI: 10.1002/syn.22199

Abstract: Information from the entorhinal cortex arrives to the hippocampal CA1 microcircuit directly through the temporoammonic path (TA) that terminates in the stratum lacunosum‐moleculare (SLM), and indirectly through Schaffer collateral pathway (SC) that terminates in the… read more here.

Keywords: hippocampus; frequency; ca1; dorsal ventral ... See more keywords
Photo by shaikhulud from unsplash

Spinal and Medullary Dorsal Horn Mechanisms

Sign Up to like & get
recommendations!
Published in 2019 at "Pain"

DOI: 10.1007/978-3-319-99124-5_5

Abstract: The dorsal horn of the spinal cord is the first relay in the transmission of painful stimuli from the periphery to higher brain centers. Primary nociceptor terminals enter the dorsal horn and form synapses with… read more here.

Keywords: dorsal horn; medullary dorsal; spinal medullary; dorsal ... See more keywords
Photo by jacksonjost from unsplash

Ethanol-Induced Taurine Elevation in the Rat Dorsal Striatum.

Sign Up to like & get
recommendations!
Published in 2017 at "Advances in experimental medicine and biology"

DOI: 10.1007/978-94-024-1079-2_15

Abstract: In the search for the primary mechanism underlying the dopamine elevating properties of ethanol we have established that raised levels of taurine in the nucleus accumbens (nAc) is pivotal. In the nAc, the release of… read more here.

Keywords: hypertonic saline; striatum; taurine dopamine; ethanol ... See more keywords
Photo from wikipedia

Is the dorsal vascular system sufficient to vascularize the entire teguments of the thumb?

Sign Up to like & get
recommendations!
Published in 2021 at "Surgical and Radiologic Anatomy"

DOI: 10.1007/s00276-020-02627-z

Abstract: Simultaneous lesions of both proper digital arteries of the thumb are common in hand trauma surgery. The purpose of this anatomical study was to determine if the dorsal arterial network could be sufficient to ensure… read more here.

Keywords: system; thumb; proper digital; dorsal vascular ... See more keywords
Photo from wikipedia

Intracavernous internal carotid artery-originating ophthalmic artery entering the orbit via the optic canal

Sign Up to like & get
recommendations!
Published in 2021 at "Surgical and Radiologic Anatomy"

DOI: 10.1007/s00276-021-02835-1

Abstract: We previously reported an original study of ophthalmic artery (OA) origin variations, titled, “Persistent dorsal ophthalmic artery and ophthalmic artery arising from the middle meningeal artery diagnosed by MR angiography at 3 T,” in Surgical… read more here.

Keywords: artery; ophthalmic artery; orbit via; anatomy ... See more keywords
Photo from wikipedia

Low-profile double plating versus dorsal LCP in stabilization of the olecranon fractures

Sign Up to like & get
recommendations!
Published in 2020 at "Archives of Orthopaedic and Trauma Surgery"

DOI: 10.1007/s00402-020-03473-9

Abstract: Introduction Proximal ulna fractures are common in orthopaedic surgery. Comminuted fractures require a high primary stability by the osteosynthesis, to allow an early functional rehabilitation as fast as possible, to reduce long-term limitations of range… read more here.

Keywords: low profile; double plates; plate; dorsal ... See more keywords
Photo from wikipedia

Reversal of spontaneous nystagmus during visual fixation in dorsal medullary infarction

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Neurology"

DOI: 10.1007/s00415-020-09754-y

Abstract: Spontaneous nystagmus (SN) in dorsal medullary infarction is usually horizontal or mixed horizontal-torsional with a small vertical component [1]. The slow phases of SN may be directed toward or away from the side of the… read more here.

Keywords: visual fixation; fixation; medullary infarction; component ... See more keywords
Photo by kellysikkema from unsplash

Bipolar dual-lead spinal cord stimulation between two electrodes on the ventral and dorsal sides of the spinal cord: consideration of putative mechanisms

Sign Up to like & get
recommendations!
Published in 2017 at "Acta Neurochirurgica"

DOI: 10.1007/s00701-017-3421-8

Abstract: We have applied bipolar dual-lead spinal cord stimulation (SCS) between two cylinder-type electrodes placed on the ventral and dorsal sides of the spinal cord (dual-VD-SCS). A 36-year-old man suffered from burning pain from his right… read more here.

Keywords: bipolar dual; cord; scs; dual lead ... See more keywords
Photo by mbphotography from unsplash

Dorsal versus ventral strip augmented anastomotic bulbar urethroplasty: retrospective study

Sign Up to like & get
recommendations!
Published in 2018 at "International Urology and Nephrology"

DOI: 10.1007/s11255-018-1899-5

Abstract: PurposeThe published literature shows controversies with regard to the treatment of choice for longer stricture. Augmented anastomotic urethroplasty (AAU) was described for long bulbar urethral strictures with an extended area of narrowing and fibrosis, the… read more here.

Keywords: strip; bulbar; urology; dorsal ... See more keywords
Photo from wikipedia

Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration

Sign Up to like & get
recommendations!
Published in 2017 at "Acta Orthopaedica et Traumatologica Turcica"

DOI: 10.1016/j.aott.2017.10.004

Abstract: Objective The aim of this study was to compare the efficiency of dorsal tangential fluoroscopy and ultrasonography in detecting dorsal screw penetration in distal radius volar locking plate applications. Methods Ten cadaveric forearms were operated.… read more here.

Keywords: detection; penetration; view; dorsal ... See more keywords