Sign Up to like & get
recommendations!
1
Published in 2018 at "Journal of Applied Clinical Medical Physics"
DOI: 10.1002/acm2.12357
Abstract: Abstract In this study, the optimum density scaling factors of phantom materials for a commercially available three‐dimensional (3D) dose verification system (Delta4) were investigated in order to improve the accuracy of the calculated dose distributions…
read more here.
Keywords:
dose verification;
phantom materials;
water;
density ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2021 at "Medical physics"
DOI: 10.1002/mp.15046
Abstract: PURPOSE In vivo range and dose verification based on proton-induced acoustics (protoacoustics) is potentially a useful tool for proton therapy. Built upon our previous study with 2D reconstruction, the time reversal (TR) method was extended…
read more here.
Keywords:
reconstruction;
dose verification;
time;
proton ... See more keywords
Sign Up to like & get
recommendations!
3
Published in 2023 at "Medical physics"
DOI: 10.1002/mp.16337
Abstract: BACKGROUND Adaptive radiotherapy has made significant advances owing to MR-LINAC, which provides superior soft-tissue contrast, fast speed and rich functional magnetic resonance imaging to guide radiotherapy. Independent dose verification plays a critical role in discovering…
read more here.
Keywords:
monte carlo;
verification module;
dose verification;
verification ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "Physica Medica"
DOI: 10.1016/j.ejmp.2018.06.566
Abstract: Purpose Radiotherapy treatment depends on the accuracy of the dose delivery in patients. The purpose of this study is to test an independent Monte-Carlo dose calculation program (PRIMO) to verify dose distributions of 6-MV-FF VMAT…
read more here.
Keywords:
dose verification;
monte carlo;
independent monte;
primo ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2020 at "Journal of Nursing Care Quality"
DOI: 10.1097/ncq.0000000000000491
Abstract: BACKGROUND The effectiveness of the dose verification features of the electronic medication administration record (eMAR) and complementary systems in the hospital setting is not well understood. PURPOSE The authors completed a narrative synthesis of literature…
read more here.
Keywords:
literature review;
emar based;
based systems;
dose verification ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2021 at "Frontiers in Oncology"
DOI: 10.3389/fonc.2021.621394
Abstract: Objective To investigate the usefulness of positron emission tomography (PET) images obtained after carbon-ion irradiation for dose verification in carbon-ion radiotherapy. Methods and Materials An anthropomorphic head phantom was used in this study. Three cubes…
read more here.
Keywords:
carbon ion;
ion;
dose verification;
pet images ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2018 at "Journal of Contemporary Brachytherapy"
DOI: 10.5114/jcb.2018.79396
Abstract: Purpose To report an implementation method and the results of independent brachytherapy dose verification software (DVS). Material and methods The DVS was developed based on Visual C++ and adopted a modular structure design. The DICOM…
read more here.
Keywords:
dvs;
dose verification;
brachytherapy;
verification software ... See more keywords