Articles with "dose water" as a keyword



Photo by a2eorigins from unsplash

[P259] Radiobiological method for the clinical validation of models dose-to-water versus dose-to-meduim in radiotherapy

Sign Up to like & get
recommendations!
Published in 2018 at "Physica Medica"

DOI: 10.1016/j.ejmp.2018.06.538

Abstract: Purpose A present challenge in medical physics is to implement the most accurate dose calculation algorithm, close to Monte Carlo simulations, with the highest safety to obtain the expected tumour control probability (TCP) and acceptable… read more here.

Keywords: dose water; radiotherapy; prescription; lung ... See more keywords
Photo by a2eorigins from unsplash

What dose specification should be used for NRG radiation therapy trials, dose-to-medium or dose-to-water?

Sign Up to like & get
recommendations!
Published in 2019 at "Practical radiation oncology"

DOI: 10.1016/j.prro.2019.08.008

Abstract: PURPOSE To compare the doses calculated by AAA, Acuros dose-to-medium and Acuros dose-to-water for the lung patients treated at our institution and show that further investigation and clarification are needed about what dose specification should… read more here.

Keywords: aaa acuros; dose water; calculated aaa; dose medium ... See more keywords
Photo by isaacmsmith from unsplash

Comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the LNE-LNHB, France and the BIPM in accelerator photon beams

Sign Up to like & get
recommendations!
Published in 2021 at "Metrologia"

DOI: 10.1088/0026-1394/58/1a/06005

Abstract: A key comparison has been made between the absorbed dose to water standards of the Laboratoire National Henri Becquerel (LNE-LNHB), France and the BIPM in accelerator photon beams. The results show the standards to be… read more here.

Keywords: comparison; bipm; lne lnhb; absorbed dose ... See more keywords
Photo from wikipedia

Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the NMIJ, Japan, and the BIPM in 60Co gamma radiation

Sign Up to like & get
recommendations!
Published in 2023 at "Metrologia"

DOI: 10.1088/0026-1394/60/1a/06008

Abstract: A new key comparison of the standards for absorbed dose to water of the National Metrology Institute of Japan (NMIJ), Japan, and the Bureau International des Poids et Mesures (BIPM) was carried out in the… read more here.

Keywords: bipm; dose water; comparison; absorbed dose ... See more keywords
Photo by thandyung from unsplash

Comparison BIPM.RI(I)-K6 of the standards for absorbed dose to water of the ARPANSA, Australia, and the BIPM in accelerator photon beams

Sign Up to like & get
recommendations!
Published in 2023 at "Metrologia"

DOI: 10.1088/0026-1394/60/1a/06011

Abstract: A key comparison has been made between the absorbed dose to water standards of the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), Australia, and the BIPM in accelerator photon beams. The results show the… read more here.

Keywords: arpansa australia; australia bipm; bipm; dose water ... See more keywords
Photo from wikipedia

Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the BFKH, Hungary and the BIPM in 60Co gamma radiation

Sign Up to like & get
recommendations!
Published in 2023 at "Metrologia"

DOI: 10.1088/0026-1394/60/1a/06014

Abstract: A new key comparison of the standards for absorbed dose to water of the Budapest Főváros Kormányhivatala (BFKH), Hungary, and the Bureau International des Poids et Mesures (BIPM) was carried out in the 60Co radiation… read more here.

Keywords: bipm; dose water; comparison; absorbed dose ... See more keywords
Photo by a2eorigins from unsplash

On the conversion from dose-to-medium to dose-to-water in heterogeneous phantoms with Acuros XB and Monte Carlo calculations.

Sign Up to like & get
recommendations!
Published in 2019 at "Physics in medicine and biology"

DOI: 10.1088/1361-6560/ab3df3

Abstract: The method implemented in Monte Carlo (MC) algorithm to convert dose-to-medium (Dm) to dose-to-water (Dw) is usually based on the Bragg-Gray cavity theory. Acuros XB (AXB) reports also Dm and Dw but the method to… read more here.

Keywords: water; dose water; conversion; axb ... See more keywords