Articles with "dosemeter" as a keyword



Photo by johnarano from unsplash

Performance of Barc Neutron Personal Dosemeter in Eurados Intercomparison Exercise IC2017N - a Lesson Learnt.

Sign Up to like & get
recommendations!
Published in 2022 at "Radiation protection dosimetry"

DOI: 10.1093/rpd/ncac058

Abstract: Bhabha Atomic Research Centre (BARC) conducts fast neutron personnel monitoring service to radiation workers involved in reactors, accelerators, spent fuel processing plants, oil-well industries, etc., using CR-39 detector based dosemeter. In this study, performance of… read more here.

Keywords: performance; intercomparison exercise; eurados intercomparison; dosemeter ... See more keywords
Photo by impulsq from unsplash

Study of Residual TL of CaSO4: Dy-based Thermoluminescence Dosemeter

Sign Up to like & get
recommendations!
Published in 2017 at "Radiation Protection Dosimetry"

DOI: 10.1093/rpd/ncx052

Abstract: Thermoluminescence (TL) signal obtained during second readout of a TL dosemeter disc previously exposed to ionising radiation is termed as residual TL. The origin of residual TL has not been discussed in detail so far in… read more here.

Keywords: caso4 based; dosemeter; based thermoluminescence; thermoluminescence ... See more keywords
Photo from wikipedia

CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY.

Sign Up to like & get
recommendations!
Published in 2019 at "Radiation protection dosimetry"

DOI: 10.1093/rpd/ncz186

Abstract: This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The… read more here.

Keywords: system; al2o3 based; stimulated luminescent; dosemeter ... See more keywords
Photo by impulsq from unsplash

A NEW TL-DOS NEUTRON DOSEMETER FOR MEASUREMENTS OF THE PERSONAL DOSE EQUIVALENT HP(10).

Sign Up to like & get
recommendations!
Published in 2019 at "Radiation protection dosimetry"

DOI: 10.1093/rpd/ncz251

Abstract: A new thermoluminescence albedo dosemeter with improved properties is developed as part of the TL-DOS project. The dosemeter measures the neutron and photon whole-body dose of radiation workers. The TL-DOS neutron dosemeter is presented and… read more here.

Keywords: neutron dosemeter; dosemeter; dos neutron; dosemeter measurements ... See more keywords