Articles with "dosimeter" as a keyword



Photo by derstudi from unsplash

MR‐safe personal radiation dosimeters

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.12115

Abstract: Abstract Magnetic resonance imaging ( MRI) is being rapidly integrated for cancer treatments—such systems are referred to as MRI‐guided radiation therapy (MRIgRT). As the magnet of an MRI scanner is always on, the presence of… read more here.

Keywords: personal radiation; dosimeter; safe personal; magnetic field ... See more keywords
Photo by nci from unsplash

A versatile radiochromic dosimeter for low‐medium gamma radiation and its application to food irradiation

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Applied Polymer Science"

DOI: 10.1002/app.45729

Abstract: This article presents a novel radiochromic film for selective detection of low-medium (0–10 kGy) gamma radiation (60Co) doses. This dosimeter is based on a printed fluorescent multilayer structure comprising a paper substrate having layers of… read more here.

Keywords: dosimeter; low medium; gamma radiation; radiation ... See more keywords
Photo by cdc from unsplash

Easy and Green Route towards Nanostructured ZnO as an Active Sensing Material with Unexpected H2 S Dosimeter-Type Behaviour

Sign Up to like & get
recommendations!
Published in 2019 at "European Journal of Inorganic Chemistry"

DOI: 10.1002/ejic.201801334

Abstract: Nanostructured ZnO particles were prepared through a straightforward, quick and low-temperature synthesis route involving coprecipitation of the metal precursor salts with oxalic acid, followed by hydrothermal treatment at 135 or 160 °C. The synthesised nanostructured… read more here.

Keywords: microscopy; dosimeter; spectroscopy; route ... See more keywords
Photo by possessedphotography from unsplash

Technical Note: ID-card-size dosimeter based on radiochromic films for continuous personnel monitoring.

Sign Up to like & get
recommendations!
Published in 2021 at "Medical physics"

DOI: 10.1002/mp.14893

Abstract: PURPOSE This paper is aimed at investigating the feasibility of developing a personal dosimeter of cumulative radiation dose which would incorporate the following features: 1) a small size comparable to that of a proximity ID… read more here.

Keywords: dosimeter; card size; technical note; size ... See more keywords
Photo by towfiqu999999 from unsplash

A study of dose verification and comparison for complex irradiation field with high dose rate radiation by using a 3D N-isopropylacrylamide gel dosimeter

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Radioanalytical and Nuclear Chemistry"

DOI: 10.1007/s10967-019-06828-8

Abstract: This study aimed to investigate dosimeter characteristics by using a photon beam with and without the flattening filter of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) by using a 3D N-isopropylacrylamide (NIPAM)… read more here.

Keywords: dosimeter; high dose; gel dosimeter; using isopropylacrylamide ... See more keywords
Photo by seemurray from unsplash

Definite comparison of resazurin film with FWT film in monitoring the absorbed irradiation dose and it is possibility of using as a label- dosimeter

Sign Up to like & get
recommendations!
Published in 2019 at "Optik"

DOI: 10.1016/j.ijleo.2019.163114

Abstract: Abstract A comparison study between the PH indicator Resazurin, (hydroxy phenoxazin) dye incorporated in poly vinyl alcohol with the most famous routine dosimeter used in commercial irradiation processes, FWT-60-00, (hexa hydroxyl ethyl pararosaniline nitrile) in… read more here.

Keywords: dosimeter; resazurin film; fwt film; film ... See more keywords
Photo from wikipedia

Exposure dose measurement during diagnostic pediatric X-ray examination using an optically stimulated luminescence (OSL) dosimeter based on precise dose calibration taking into consideration variation of X-ray spectra

Sign Up to like & get
recommendations!
Published in 2018 at "Radiation Measurements"

DOI: 10.1016/j.radmeas.2018.10.007

Abstract: Abstract When dosimetry is performed in actual clinical situations using diagnostic X-rays, the energy dependence of the dosimeter should be taken into consideration. Although the dosimeter is calibrated with standard X-rays, it is unclear whether… read more here.

Keywords: dosimeter; ray examination; pediatric ray; calibration ... See more keywords
Photo from wikipedia

Occupational eye dose in interventional cardiology procedures

Sign Up to like & get
recommendations!
Published in 2017 at "Scientific Reports"

DOI: 10.1038/s41598-017-00556-3

Abstract: It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel… read more here.

Keywords: dosimeter; interventional cardiology; cardiology; eye dose ... See more keywords
Photo from wikipedia

Uncertainties in occupational eye lens doses from dosimeters over the apron in interventional practices

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Radiological Protection"

DOI: 10.1088/1361-6498/ac5187

Abstract: It is relevant to estimate the uncertainties in the measurement of eye lens doses from a personal dosimeter over the protective apron without using additional dosimetry near the eyes. Additional dosimetry for interventionists represents a… read more here.

Keywords: eye lens; uncertainties occupational; eye; dosimeter ... See more keywords
Photo from wikipedia

Occupational doses in interventional angiography after radiological protection training and use of a real-time direct display dosimeter

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Radiological Protection"

DOI: 10.1088/1361-6498/ac7aec

Abstract: Vascular x-ray guided interventions are complex and may result in high occupational doses to ionising radiation if staff do not take appropriate actions to minimise their exposure. In this prospective intervention study, ten staff members… read more here.

Keywords: radiological protection; staff; display; real time ... See more keywords
Photo by _louisreed from unsplash

Cardiologist’s exposure to radiation in cath lab measured with InstadoseTM dosimeter

Sign Up to like & get
recommendations!
Published in 2023 at "Journal of Radiological Protection"

DOI: 10.1088/1361-6498/acb82b

Abstract: Introduction: complex fluoroscopy-guided interventional procedures in cardiology are known to result in higher radiation doses for patients and staff. Purpose: to estimate the equivalent dose received in different regions of the cardiologist’s body in catheterism… read more here.

Keywords: cath lab; tld 100; region; 100 instadosetm ... See more keywords