Articles with "dosimetric characterization" as a keyword



Photo by akshayspaceship from unsplash

Dosimetric characterization of a body‐conforming radiochromic sheet

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.12838

Abstract: Abstract Purpose A novel radiochromic PRESAGE sheet (Heuris Inc.) with 3 mm thickness has been developed as a measurement tool for 2D dosimetry. Its inherent ability to conform to irregular surfaces makes this dosimeter advantageous… read more here.

Keywords: presage sheet; surface; dosimetric characterization; sheet ... See more keywords
Photo from wikipedia

Design and Dosimetric Characterization of a Broadband Exposure Facility for In Vitro Experiments in the Frequency Range 18-40.5 GHz.

Sign Up to like & get
recommendations!
Published in 2021 at "Bioelectromagnetics"

DOI: 10.1002/bem.22376

Abstract: A novel exposure facility for exposing cell monolayers to centimeter and millimeter waves (18-40.5 GHz) used by future 5G mobile communication technology and similar applications has been developed. A detailed dosimetric characterization of the apparatus for… read more here.

Keywords: exposure facility; exposure; dosimetric characterization; cell ... See more keywords
Photo by kellysikkema from unsplash

A directional 103Pd brachytherapy device: Dosimetric characterization and practical aspects for clinical use.

Sign Up to like & get
recommendations!
Published in 2017 at "Brachytherapy"

DOI: 10.1016/j.brachy.2016.11.011

Abstract: PURPOSE A brachytherapy (BT) device has been developed with shielding to provide directional BT for preferentially irradiating malignancies while sparing healthy tissues. The CivaSheet is a flexible low-dose-rate BT device containing CivaDots with 103Pd shielded… read more here.

Keywords: dosimetric characterization; clinical use; brachytherapy device; device ... See more keywords
Photo by chasta03 from unsplash

Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE.

Sign Up to like & get
recommendations!
Published in 2017 at "Brachytherapy"

DOI: 10.1016/j.brachy.2017.04.245

Abstract: PURPOSE 60Co sources have been commercialized as an alternative to 192Ir sources for high-dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this… read more here.

Keywords: source; dosimetric characterization; rate; penelope ... See more keywords
Photo by julienlphoto from unsplash

A revised dosimetric characterization of 60Co BEBIG source: From single-source data to clinical dose distribution.

Sign Up to like & get
recommendations!
Published in 2018 at "Brachytherapy"

DOI: 10.1016/j.brachy.2018.08.011

Abstract: PURPOSE Although the dosimetric characterization of 60Co BEBIG source can be found in several literature studies, the data sets show major discrepancies and the lack of uncertainty analyses. This study tried to determine an accurate… read more here.

Keywords: single source; source; 60co bebig; dosimetric characterization ... See more keywords