Articles with "double tuned" as a keyword



Photo by alinabelogolova from unsplash

Double‐tuned 31P/1H human head array with high performance at both frequencies for spectroscopic imaging at 9.4T

Sign Up to like & get
recommendations!
Published in 2020 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.28176

Abstract: To develop a robust design of a human head double‐tuned 31P/1H array, which provides good performance at both 31P and 1H frequencies for MR spectroscopic imaging at 9.4T. read more here.

Keywords: spectroscopic imaging; frequencies spectroscopic; double tuned; human head ... See more keywords
Photo from wikipedia

Design of Distributed Spiral Resonators for the Decoupling of MRI Double-Tuned RF Coils

Sign Up to like & get
recommendations!
Published in 2020 at "IEEE Transactions on Biomedical Engineering"

DOI: 10.1109/tbme.2020.2971843

Abstract: Objective: A systematic analytical approach to design Spiral Resonators (SRs), acting as distributed magnetic traps (DMTs), for the decoupling of concentric Double-Tuned (DT) RF coils suitable for Ultra-High Field (7 T) MRI is presented. Methods:… read more here.

Keywords: spiral resonators; tuned coils; double tuned; mri ... See more keywords
Photo from wikipedia

Development and Implementation of a PIN-Diode Controlled, Quadrature-Enhanced, Double-Tuned RF Coil for Sodium MRI

Sign Up to like & get
recommendations!
Published in 2018 at "IEEE Transactions on Medical Imaging"

DOI: 10.1109/tmi.2017.2786466

Abstract: Sodium (23Na) MRI provides complementary cellular and metabolic information. However, the intrinsic MR sensitivity of 23Na is considerably lower compared with that of the proton, making it difficult to measure MR-detectable sodium signals. It is… read more here.

Keywords: double tuned; tuned coil; sodium; coil ... See more keywords
Photo from wikipedia

Design and Construction of a PET-Compatible Double-Tuned 1H/31P MR Head Coil

Sign Up to like & get
recommendations!
Published in 2021 at "IEEE Transactions on Medical Imaging"

DOI: 10.1109/tmi.2021.3070626

Abstract: Simultaneous MR-PET is an increasingly popular multimodal imaging technique that is able to combine metabolic information obtained from PET with anatomical/functional information from MRI. One of the key technological challenges of the technique is the… read more here.

Keywords: tuned 31p; double tuned; head coil; pet ... See more keywords
Photo from wikipedia

Design of a Folded, Double-Tuned Loop Coil for ¹H/X-Nuclei MRI Applications

Sign Up to like & get
recommendations!
Published in 2022 at "IEEE Transactions on Medical Imaging"

DOI: 10.1109/tmi.2022.3228305

Abstract: MR measurement using a combination of X-nuclei and proton MRI is of great interest as the information provided by the two nuclei is highly complementary, with the X-nuclei signal giving metabolic data relating to potential… read more here.

Keywords: folded double; double tuned; tex math; inline formula ... See more keywords
Photo by julianhochgesang from unsplash

Harmonic Load Mitigation Using the Optimal Double Tuned Passive Filter Technique

Sign Up to like & get
recommendations!
Published in 2017 at "Indonesian Journal of Electrical Engineering and Computer Science"

DOI: 10.11591/ijeecs.v6.i2.pp338-348

Abstract: Harmonic is one of the power quality disturbances customarily imminent in an unbalanced electrical system. Harmonic represents as the multiple integral of fundamental frequency of voltage and current inflicting towards the shifting in system frequency… read more here.

Keywords: system; double tuned; tuned passive; passive filter ... See more keywords