Articles with "drainage implant" as a keyword



Photo by miracleday from unsplash

Aurolab Aqueous Drainage Implant (AADI): Review of Indications, Mechanism, Surgical Technique, Outcomes, Impact and Limitations

Sign Up to like & get
recommendations!
Published in 2022 at "Seminars in Ophthalmology"

DOI: 10.1080/08820538.2022.2082254

Abstract: ABSTRACT Purpose The purpose of this review is to place together all the knowledge available on aurolab aqueous drainage implant (AADI) in one place for the benefit of all glaucoma specialists who are interested in… read more here.

Keywords: drainage; aadi; drainage implant; implant aadi ... See more keywords
Photo from wikipedia

Treatment of Uveitis and Outcomes of Glaucoma Drainage Implant Surgery: A Meta-Analysis

Sign Up to like & get
recommendations!
Published in 2019 at "Ocular Immunology and Inflammation"

DOI: 10.1080/09273948.2019.1629602

Abstract: ABSTRACT Purpose We performed a meta-analysis to evaluate the effect of uveitis treatment on glaucoma drainage implant surgical outcomes. Methods We included 16 articles in the meta-analysis. Two groups were defined based on medical therapy… read more here.

Keywords: drainage implant; meta analysis; implant surgery; glaucoma drainage ... See more keywords
Photo from wikipedia

INFECTIOUS ENDOPHTHALMITIS AFTER GLAUCOMA DRAINAGE IMPLANT SURGERY: Clinical Features, Microbial Spectrum, and Outcomes

Sign Up to like & get
recommendations!
Published in 2017 at "Retina"

DOI: 10.1097/iae.0000000000001329

Abstract: Purpose: To report the clinical features, microbial spectrum, and treatment outcomes of endophthalmitis after glaucoma drainage implant (GDI) surgery. Methods: Records of patients diagnosed with endophthalmitis after GDI surgery were reviewed. Data on clinical course,… read more here.

Keywords: drainage implant; surgery; endophthalmitis; glaucoma drainage ... See more keywords
Photo from wikipedia

Long-term surgical outcomes of Aurolab aqueous drainage implant in pediatric eyes with primary congenital glaucoma versus aphakic glaucoma

Sign Up to like & get
recommendations!
Published in 2022 at "British Journal of Ophthalmology"

DOI: 10.1136/bjo-2022-321571

Abstract: Purpose To compare the outcomes of the Aurolab aqueous drainage implant (AADI) placed in eyes with refractory primary congenital glaucoma (PCG) versus aphakic glaucoma (APG). Design Retrospective comparative interventional case series. Methods Case files of… read more here.

Keywords: glaucoma; drainage implant; aqueous drainage; outcomes aurolab ... See more keywords
Photo from wikipedia

Risk factors for exposure of Baerveldt glaucoma drainage implants: a case-control study

Sign Up to like & get
recommendations!
Published in 2020 at "BMC Ophthalmology"

DOI: 10.1186/s12886-020-01632-5

Abstract: Background Glaucoma drainage implant exposure is one of the serious complications after glaucoma drainage implant surgery. The purpose of this study is to evaluate the risk factors for exposure of the device after implantation of… read more here.

Keywords: risk; drainage; drainage implant; baerveldt glaucoma ... See more keywords
Photo by miracleday from unsplash

PEDI (Pullout Exteriorized Drainage Implant) suture: Case report of an improved ripcord technique in glaucoma drainage implant devices

Sign Up to like & get
recommendations!
Published in 2020 at "Clinical Ophthalmology"

DOI: 10.35841/clinical-ophthalmology.4.s1.13-15

Abstract: Background: To describe the PEDI (Pullout Exteriorized Drainage Implant) suture technique, an improvement on the ripcord technique that can be removed in the office setting under topical anesthesia. Case presentation: A 5-year-old girl with congenital… read more here.

Keywords: drainage implant; suture; ripcord technique; technique ... See more keywords
Photo from wikipedia

Safety and efficacy of Aurolab aqueous drainage implant in refractory glaucoma: A prospective study

Sign Up to like & get
recommendations!
Published in 2022 at "Indian Journal of Ophthalmology"

DOI: 10.4103/ijo.ijo_1391_22

Abstract: Purpose: This study was conducted to assess the intraocular pressure (IOP) control and postoperative complications following a non-valved glaucoma drainage device (GDD) surgery in refractory glaucoma. Methods: This was a prospective interventional study conducted on… read more here.

Keywords: drainage; drainage implant; aqueous drainage; refractory glaucoma ... See more keywords
Photo from wikipedia

Commentary: Retinal detachment in eyes treated with Aurolab aqueous drainage implant for refractory glaucoma - Incidence and outcomes

Sign Up to like & get
recommendations!
Published in 2022 at "Indian Journal of Ophthalmology"

DOI: 10.4103/ijo.ijo_2999_21

Abstract: The principal indication for glaucoma drainage devices (GDDs) is usually glaucoma refractory to filtering surgery.[1] Currently, commonly available GDDs are either valved like the Ahmed glaucoma valve (AGV; New World Medical Inc., Rancho Cucamonga, CA,… read more here.

Keywords: drainage; refractory; glaucoma; drainage implant ... See more keywords