Articles with "dual mobility" as a keyword



Photo from wikipedia

The linear penetration rate is not relevant for evaluating wear of dual mobility cups: an explant study

Sign Up to like & get
recommendations!
Published in 2017 at "International Orthopaedics"

DOI: 10.1007/s00264-017-3406-5

Abstract: PurposeThe linear penetration rate (LPR) has been used to estimate volumetric wear ever since metal-on-polyethylene bearings were first introduced. Annual volumetric wear and osteolysis are interrelated. The use of dual mobility cups has increased; however,… read more here.

Keywords: linear penetration; wear dual; mobility; penetration rate ... See more keywords
Photo from wikipedia

Dual mobility hip arthroplasty provides better outcomes compared to hemiarthroplasty for displaced femoral neck fractures: a retrospective comparative clinical study

Sign Up to like & get
recommendations!
Published in 2018 at "International Orthopaedics"

DOI: 10.1007/s00264-018-3767-4

Abstract: PurposeTotal hip arthroplasty with a dual mobility cup (DMC) is a proposed alternative to the widely performed bipolar hemiarthroplasty (BHA) for treating displaced intracapsular femoral neck fractures (DFNF) in the elderly. However, the comparison between… read more here.

Keywords: neck fractures; femoral neck; hip; hip arthroplasty ... See more keywords
Photo from wikipedia

Catastrophic failure of a dual mobility bearing in a revision total hip arthroplasty

Sign Up to like & get
recommendations!
Published in 2018 at "Arthroplasty Today"

DOI: 10.1016/j.artd.2018.03.004

Abstract: The following case demonstrates an example of a catastrophic failure of a dual mobility (DM) bearing used in the setting of a revision total hip arthroplasty for an acetabular component with an excessive abduction angle.… read more here.

Keywords: mobility bearing; revision; failure dual; catastrophic failure ... See more keywords
Photo from wikipedia

Cementation of a monoblock dual mobility bearing in a newly implanted porous revision acetabular component in patients undergoing revision total hip arthroplasty

Sign Up to like & get
recommendations!
Published in 2019 at "Arthroplasty Today"

DOI: 10.1016/j.artd.2019.05.001

Abstract: Background The most common indications for revision total hip arthroplasty are instability/dislocation and mechanical loosening. Efforts to address this have included the use of dual mobility (DM) articulations. The aim of this study is to… read more here.

Keywords: revision; hip; revision total; hip arthroplasty ... See more keywords
Photo by owenbeard from unsplash

Total Hip Arthroplasty Using a Hemispherical Uncemented Dual-Mobility Cup Results in Satisfactory Clinical Outcomes and No Dislocations at 2 years

Sign Up to like & get
recommendations!
Published in 2021 at "Arthroplasty Today"

DOI: 10.1016/j.artd.2021.04.017

Abstract: Background The authors performed total hip arthroplasty (THA) using a novel hemispherical dual-mobility (DM) acetabular cup without a protrusive cylindro-spherical rim, intended to reduce risks of iliopsoas impingement without requiring changes to conventional intraoperative positioning… read more here.

Keywords: hip arthroplasty; hip; cup; dual mobility ... See more keywords
Photo by majestical_jasmin from unsplash

Dual mobility acetabular construct with freedom constrained liner for treatment of recurrent dislocations after total hip arthroplasty: A case report and literature review

Sign Up to like & get
recommendations!
Published in 2020 at "International Journal of Surgery Case Reports"

DOI: 10.1016/j.ijscr.2020.09.012

Abstract: Highlights • Dual-mobility bearings improve stability in total hip arthroplasty (THA) but may fail to prevent postoperative dislocation.• Dry revision with a compatible constrained liner system can provide an effective salvage option for instability after… read more here.

Keywords: constrained liner; hip arthroplasty; dual mobility; total hip ... See more keywords
Photo from wikipedia

Outcomes for cemented dual mobility cup to treat recurrent instability; A UK case series.

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of orthopaedics"

DOI: 10.1016/j.jor.2019.02.025

Abstract: Objectives Recurrent dislocation of Total Hip Replacement (THR) is often multifactorial and remains a significant surgical challenge with a significant risk of further instability. Dual Mobility Cups (DMC) have been used widely with good long… read more here.

Keywords: dual mobility; mobility cups; mobility cup; recurrent instability ... See more keywords
Photo from wikipedia

Dual mobility acetabular cups for total hip arthroplasty: advantages and drawbacks

Sign Up to like & get
recommendations!
Published in 2018 at "Expert Review of Medical Devices"

DOI: 10.1080/17434440.2018.1538781

Abstract: ABSTRACT Introduction: The dual mobility cup (DMC) concept was proposed by Professor Gilles Bousquet in 1974. Its’ aims were to prevent postoperative dislocation, restore the physiological range of motion of the hip, and reduce the… read more here.

Keywords: hip; mobility; mobility acetabular; acetabular cups ... See more keywords
Photo from wikipedia

Comparison of dual-mobility cup and unipolar cup for prevention of dislocation after revision total hip arthroplasty

Sign Up to like & get
recommendations!
Published in 2017 at "Acta Orthopaedica"

DOI: 10.1080/17453674.2016.1255482

Abstract: Background and purpose — Revision total hip arthroplasty (THA) is associated with higher dislocation rates than primary THA. We compared the risk of dislocation within 6 months and all-cause re-revision during the whole study period… read more here.

Keywords: revision; dislocation; mobility cup; cup ... See more keywords
Photo from wikipedia

What Is the Risk of Dislocation and Revision in Proximal Femoral Replacement with Dual-mobility Articulation After Two-stage Revision for Periprosthetic Hip Infection?

Sign Up to like & get
recommendations!
Published in 2023 at "Clinical orthopaedics and related research"

DOI: 10.1097/corr.0000000000002623

Abstract: BACKGROUND Dislocation is a major complication of revision THA after two-stage exchange for periprosthetic joint infection (PJI). The likelihood of dislocation can be particularly high if megaprosthetic proximal femoral replacement (PFR) has been performed during… read more here.

Keywords: revision; dual mobility; risk; dislocation ... See more keywords
Photo by majestical_jasmin from unsplash

Dual mobility hip arthroplasty: iatrogenic intraprosthetic dislocation of a 22 mm head

Sign Up to like & get
recommendations!
Published in 2022 at "BMJ Case Reports"

DOI: 10.1136/bcr-2021-245859

Abstract: We describe the first intraprosthetic dislocations of a 22 mm head in a dual mobility hip replacement in the literature. This case emphasises the importance of information gathering and planning when dealing with arthroplasty complications.… read more here.

Keywords: iatrogenic intraprosthetic; mobility hip; dual mobility; dislocation ... See more keywords