Articles with "echo planar" as a keyword



Photo by hckmstrrahul from unsplash

Simultaneous multislice readout‐segmented echo planar imaging for accelerated diffusion tensor imaging of the mandibular nerve: A feasibility study

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Magnetic Resonance Imaging"

DOI: 10.1002/jmri.25603

Abstract: To assess the feasibility of diffusion tensor imaging (DTI) using simultaneous multislice (SMS) acquisition with blipped controlled aliasing in parallel imaging (CAIPI) for accelerated readout‐segmented echo planar imaging (rs‐EPI) of the mandibular nerves. DTI of… read more here.

Keywords: simultaneous multislice; echo planar; tensor imaging; segmented echo ... See more keywords
Photo from wikipedia

Readout‐Segmented Echo‐Planar Diffusion‐Weighted MR Imaging Improves the Differentiation of Breast Cancer Receptor Statuses Compared With Conventional Diffusion‐Weighted Imaging

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Magnetic Resonance Imaging"

DOI: 10.1002/jmri.28065

Abstract: Readout‐segmented echo‐planar diffusion‐weighted imaging (RS‐EPI) can improve image quality and signal‐to‐noise ratio, the resulting apparent diffusion coefficient (ADC) value acts as a more sensitive biomarker to characterize tumors. However, data regarding the differentiation of breast… read more here.

Keywords: diffusion; diffusion weighted; segmented echo; echo planar ... See more keywords
Photo from wikipedia

Magnetic Resonance Elastography of Intervertebral Discs: Spin‐Echo Echo‐Planar Imaging Sequence Validation

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Magnetic Resonance Imaging"

DOI: 10.1002/jmri.28151

Abstract: Magnetic resonance elastography (MRE) is an imaging technique that can noninvasively assess the shear properties of the intervertebral disc (IVD). Unlike the standard gradient recalled echo (GRE) MRE technique, a spin‐echo echo‐planar imaging (SE‐EPI) sequence… read more here.

Keywords: magnetic resonance; spin echo; resonance elastography; echo echo ... See more keywords
Photo by sarahsosiak from unsplash

Quiet echo planar imaging for functional and diffusion MRI

Sign Up to like & get
recommendations!
Published in 2018 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.26810

Abstract: To develop a purpose‐built quiet echo planar imaging capability for fetal functional and diffusion scans, for which acoustic considerations often compromise efficiency and resolution as well as angular/temporal coverage. read more here.

Keywords: functional diffusion; quiet echo; echo planar; planar imaging ... See more keywords
Photo from wikipedia

Diffusion tensor cardiovascular magnetic resonance with a spiral trajectory: An in vivo comparison of echo planar and spiral stimulated echo sequences

Sign Up to like & get
recommendations!
Published in 2018 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.27051

Abstract: Diffusion tensor cardiovascular MR (DT‐CMR) using stimulated echo acquisition mode (STEAM) with echo‐planar‐imaging (EPI) readouts is a low signal‐to‐noise‐ratio (SNR) technique and therefore typically has a low spatial resolution. Spiral trajectories are more efficient than… read more here.

Keywords: echo planar; tensor cardiovascular; magnetic resonance; stimulated echo ... See more keywords
Photo by sarahsosiak from unsplash

On the limitations of echo planar 4D flow MRI

Sign Up to like & get
recommendations!
Published in 2020 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.28236

Abstract: To compare EPI and GRE readout in high‐flow velocity regimes and evaluate their impact on measurement accuracy in silico and in vitro. read more here.

Keywords: limitations echo; medicine; flow mri; echo planar ... See more keywords
Photo by stevencornfield from unsplash

An artificial intelligence‐accelerated 2‐minute multi‐shot echo planar imaging protocol for comprehensive high‐quality clinical brain imaging

Sign Up to like & get
recommendations!
Published in 2021 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.29117

Abstract: We introduce and validate an artificial intelligence (AI)‐accelerated multi‐shot echo‐planar imaging (msEPI)‐based method that provides T1w, T2w, T2∗ , T2‐FLAIR, and DWI images with high SNR, high tissue contrast, low specific absorption rates (SAR), and… read more here.

Keywords: shot echo; intelligence accelerated; planar imaging; multi shot ... See more keywords
Photo from wikipedia

Metabolite‐cycled echo‐planar spectroscopic imaging of the human heart

Sign Up to like & get
recommendations!
Published in 2022 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.29333

Abstract: Spectroscopic imaging could provide insights into regional cardiac triglyceride variations, but is hampered by relatively long scan times. It is proposed to synergistically combine echo‐planar spectroscopic imaging (EPSI) with motion‐adapted gating, weighted acquisition and metabolite… read more here.

Keywords: human heart; planar spectroscopic; spectroscopic; echo planar ... See more keywords
Photo by martindorsch from unsplash

High‐resolution motion‐ and phase‐corrected functional MRI at 7 T using shuttered multishot echo‐planar imaging

Sign Up to like & get
recommendations!
Published in 2023 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.29608

Abstract: To achieve high‐resolution multishot echo‐planar imaging (EPI) for functional MRI (fMRI) with reduced sensitivity to in‐plane motion and between‐shot phase variations. read more here.

Keywords: multishot echo; functional mri; high resolution; planar imaging ... See more keywords
Photo from wikipedia

Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis

Sign Up to like & get
recommendations!
Published in 2019 at "European Radiology"

DOI: 10.1007/s00330-019-06491-3

Abstract: Objectives To qualitatively and quantitatively compare the image quality between single-shot echo-planar (SS-EPI) and multi-shot echo-planar (IMS-EPI) diffusion-weighted imaging (DWI) in female pelvis Methods This was a prospective study involving 80 females who underwent 3.0T… read more here.

Keywords: quality; shot echo; image quality; echo planar ... See more keywords
Photo from wikipedia

Echo-planar imaging is superior to fast spin-echo diffusion-weighted imaging for cranioplasty using titanium mesh in brain magnetic resonance imaging: a phantom study

Sign Up to like & get
recommendations!
Published in 2021 at "Radiological Physics and Technology"

DOI: 10.1007/s12194-021-00646-y

Abstract: This study aimed to compare the radiofrequency (RF) shielding effects of titanium mesh of echo-planar imaging (EPI) versus fast spin-echo (FSE) diffusion-weighted imaging (DWI) to establish a suitable sequence for patients who undergo cranioplasty and… read more here.

Keywords: diffusion; planar imaging; fast spin; titanium mesh ... See more keywords