Articles with "electrode array" as a keyword



Photo from wikipedia

A Ferroelectric Ceramic/Polymer Composite‐Based Capacitive Electrode Array for In Vivo Recordings

Sign Up to like & get
recommendations!
Published in 2017 at "Advanced Healthcare Materials"

DOI: 10.1002/adhm.201700305

Abstract: A new implantable capacitive electrode array for electrocorticography signal recording is developed with ferroelectric ceramic/polymer composite. This ultrathin and electrically safe capacitive electrode array is capable of attaching to the biological tissue conformably. The barium… read more here.

Keywords: array; ferroelectric ceramic; capacitive electrode; electrode array ... See more keywords
Photo from wikipedia

Highly Stretchable Metal-Polymer Conductor Electrode Array for Electrophysiology.

Sign Up to like & get
recommendations!
Published in 2020 at "Advanced healthcare materials"

DOI: 10.1002/adhm.202000641

Abstract: Narrowing the mechanical mismatch between biological tissues (typically soft) and neural interfaces (hard) is essential for maintaining signal quality for the electrical recording of neural activity. However, only a few materials can satisfy all requirements… read more here.

Keywords: highly stretchable; metal polymer; sea; electrode array ... See more keywords
Photo from wikipedia

Multimodal Electrocorticogram Active Electrode Array Based on Zinc Oxide‐Thin Film Transistors

Sign Up to like & get
recommendations!
Published in 2022 at "Advanced Science"

DOI: 10.1002/advs.202204467

Abstract: Active electrocorticogram (ECoG) electrodes can amplify the weak electrophysiological signals and improve the anti-interference ability, but the traditional active electrodes are so opaque that cannot realize photoelectric collaborative observation. Here an active and fully-transparent ECoG… read more here.

Keywords: brain; ecog array; array based; electrode array ... See more keywords
Photo from archive.org

The standardized EEG electrode array of the IFCN

Sign Up to like & get
recommendations!
Published in 2017 at "Clinical Neurophysiology"

DOI: 10.1016/j.clinph.2017.06.254

Abstract: Standardized EEG electrode positions are essential for both clinical applications and research. The aim of this guideline is to update and expand the unifying nomenclature and standardized positioning for EEG scalp electrodes. Electrode positions were… read more here.

Keywords: array; array ifcn; eeg electrode; electrode array ... See more keywords
Photo from wikipedia

Visualising the dynamic processes of flow accelerated corrosion and erosion corrosion using an electrochemically integrated electrode array

Sign Up to like & get
recommendations!
Published in 2018 at "Corrosion Science"

DOI: 10.1016/j.corsci.2018.05.032

Abstract: Abstract An electrochemically integrated and individually addressable multi-electrode array has been proposed and demonstrated as a new tool for simulating, visualising and monitoring the dynamic processes of flow accelerated corrosion (FAC) and erosion corrosion under… read more here.

Keywords: erosion corrosion; electrode array; corrosion; electrochemically integrated ... See more keywords
Photo from wikipedia

The pattern and degree of capsular fibrous sheaths surrounding cochlear electrode arrays

Sign Up to like & get
recommendations!
Published in 2017 at "Hearing Research"

DOI: 10.1016/j.heares.2017.02.012

Abstract: ABSTRACT An inflammatory tissue reaction around the electrode array of a cochlear implant (CI) is common, in particular at the electrode insertion region (cochleostomy) where mechanical trauma often occurs. However, the factors determining the amount… read more here.

Keywords: thickness fibrous; tissue; electrode; electrode array ... See more keywords
Photo by miracleday from unsplash

The misplaced cochlear implant electrode array.

Sign Up to like & get
recommendations!
Published in 2019 at "International journal of pediatric otorhinolaryngology"

DOI: 10.1016/j.ijporl.2018.11.027

Abstract: OBJECTIVES/HYPOTHESIS Evaluation of the clinical, electrophysiologic findings, the management plans of the misplaced cochlear implant electrode array and the possible causes of misplacement. Also to provide recommendations to prevent a repeat of cochlear implant electrode… read more here.

Keywords: misplaced cochlear; electrode array; implant electrode; cochlear implant ... See more keywords
Photo by davidhellmann from unsplash

Modeling for apparent resistivity estimation along direction of electrode array above rebar in electrical resistivity measurement

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of building engineering"

DOI: 10.1016/j.jobe.2020.101417

Abstract: Abstract This paper proposes a method for estimating the resistivity of concrete surrounding a specific reinforcing bar using an electrical resistivity method above the steel bar. The previously proposed resistivity estimation model (REM) can estimate… read more here.

Keywords: resistivity; steel; apparent resistivity; bar ... See more keywords
Photo by dulhiier from unsplash

Fast Reconfigurable Electrode Array Based on Titanium Oxide for Localized Stimulation of Cultured Neural Network.

Sign Up to like & get
recommendations!
Published in 2023 at "ACS applied materials & interfaces"

DOI: 10.1021/acsami.2c21649

Abstract: Planar microelectrode arrays have become standard tools for in vitro neural-network analysis. However, these predefined micropatterned devices lack adaptability to target-specific cells within a cultured network. Herein, we fabricated a reconfigurable TiO2 electrode array with… read more here.

Keywords: electrode; neural network; network; tio2 ... See more keywords
Photo from wikipedia

Advantageous environment of micro-patterned, high-density complementary metal–oxide–semiconductor electrode array for spiral ganglion neurons cultured in vitro

Sign Up to like & get
recommendations!
Published in 2018 at "Scientific Reports"

DOI: 10.1038/s41598-018-25814-w

Abstract: This study investigated micro-patterned, high-density complementary metal–oxide–semiconductor (CMOS) electrode array to be used as biologically permissive environment for organization, guidance and electrical stimulation of spiral ganglion neurons (SGN). SGNs extracted and isolated from cochleae of… read more here.

Keywords: high density; density complementary; micro patterned; patterned high ... See more keywords
Photo by miracleday from unsplash

Mechanisms of electrode fold-over in cochlear implant surgery when using a flexible and slim perimodiolar electrode array

Sign Up to like & get
recommendations!
Published in 2017 at "Acta Oto-Laryngologica"

DOI: 10.1080/00016489.2016.1271449

Abstract: Abstract Objectives: This study evaluates the design of a thin perimodiolar cochlear implant electrode array (CI532) and assesses insertion-related rotation and fold-over. Methods: The study consisted on a cochlear model and temporal bone insertion studies.… read more here.

Keywords: insertion; cochlear implant; mechanisms electrode; electrode ... See more keywords