Articles with "electronic portal" as a keyword



Photo from wikipedia

Determination of the electronic portal imaging device pixel-sensitivity-map for quality assurance applications. Part 1: Comparison of methods.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of applied clinical medical physics"

DOI: 10.1002/acm2.13603

Abstract: PURPOSE Calibration of a radiotherapy electronic portal imaging device (EPID) using the pixel-sensitivity-map (PSM) in place of the flood field correction improves the utility of the EPID for quality assurance applications. Multiple methods are available… read more here.

Keywords: imaging device; portal imaging; method; sensitivity map ... See more keywords
Photo by philldane from unsplash

Variation in Elekta iView electronic portal imager pixel scale factor with gantry angle, and impact on multi‐leaf collimator quality assurance

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Applied Clinical Medical Physics"

DOI: 10.1002/acm2.13661

Abstract: Abstract For Elekta Agility linear accelerators, the iViewGT electronic portal imaging device (EPID) is positioned at a nominal X‐Ray source‐to‐panel distance of 1600 mm. For display, image registration, and data processing purposes, the image pixels… read more here.

Keywords: electronic portal; leaf collimator; multi leaf; gantry ... See more keywords
Photo by topdata from unsplash

Assessing the accuracy of electronic portal imaging device (EPID)-based dosimetry: I. Quantities influencing long-term stability.

Sign Up to like & get
recommendations!
Published in 2021 at "Medical physics"

DOI: 10.1002/mp.15434

Abstract: PURPOSE The aim of this study is to reduce the uncertainty associated with determining dose-to-water using an amorphous silicon electronic portal imaging detector (EPID) under reference conditions by identifying and accounting for operational and environmental… read more here.

Keywords: portal imaging; long term; electronic portal; term stability ... See more keywords
Photo from wikipedia

Oncology Nursing Perceptions of Patient Electronic Portal Use: A Qualitative Analysis

Sign Up to like & get
recommendations!
Published in 2017 at "Clinical Journal of Oncology Nursing"

DOI: 10.1188/17.onf.165-170

Abstract: Purpose/Objectives: To identify nursing staff reactions to and perceptions of electronic portal use in a cancer setting. Research Approach: Qualitative. Setting: Outpatient clinic at the Harold C. Simmons Comprehensive Cancer Center of the University of… read more here.

Keywords: portal use; analysis; oncology; electronic portal ... See more keywords
Photo from wikipedia

Setup in a clinical workflow and impact on radiotherapy routine of an in vivo dosimetry procedure with an electronic portal imaging device

Sign Up to like & get
recommendations!
Published in 2018 at "PLoS ONE"

DOI: 10.1371/journal.pone.0192686

Abstract: High conformal techniques such as intensity-modulated radiation therapy and volumetric-modulated arc therapy are widely used in overloaded radiotherapy departments. In vivo dosimetric screening is essential in this environment to avoid important dosimetric errors. This work… read more here.

Keywords: imaging device; radiotherapy; procedure; dosimetry ... See more keywords
Photo by topdata from unsplash

Validation of a simple technique for accurate treatment delivery for bilateral breast irradiation using the electronic portal imaging device

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of Cancer Research and Therapeutics"

DOI: 10.4103/jcrt.jcrt_1271_21

Abstract: Background and Aims: While bilateral breast cancer is rare, the challenge for the radiation oncologist is to limit the dose to multiple important organs-at-risk and reducing the chance of overlapping tangential fields to limit hotspots.… read more here.

Keywords: electronic portal; using electronic; bilateral breast; breast ... See more keywords
Photo by aaronburden from unsplash

Simple Electronic Portal Imager-Based Pretreatment Quality Assurance using Acuros XB: A Feasibility Study

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Medical Physics"

DOI: 10.4103/jmp.jmp_84_19

Abstract: Objective: This study demonstrates a novel electronic portal imaging device (EPID)-based forward dosimetry approach for pretreatment quality assurance aided by a treatment planning system (TPS). Materials and Methods: Dynamic multileaf collimator intensity-modulated radiation therapy (IMRT)… read more here.

Keywords: pretreatment quality; fluence; study; heterogeneity ... See more keywords