Articles with "embolic protection" as a keyword



Watchman in ascending aorta for systemic protection (WAASP): Novel use of Watchman in ascending aorta for embolic protection—first in man

Sign Up to like & get
recommendations!
Published in 2018 at "Catheterization and Cardiovascular Interventions"

DOI: 10.1002/ccd.27117

Abstract: We report two cases where left atrial appendage closure (LAA) with Watchman was successfully performed despite presence of definite LAA thrombus. Because there was the risk of thrombus dislodgement, we transiently placed an additional Watchman… read more here.

Keywords: protection; embolic protection; aorta embolic; ascending aorta ... See more keywords
Photo from archive.org

In Silico Hemodynamics and Filtering Evaluation of a Commercial Embolic Protection Device

Sign Up to like & get
recommendations!
Published in 2021 at "Annals of Biomedical Engineering"

DOI: 10.1007/s10439-021-02846-4

Abstract: During the last years, several kinds of Embolic Protection Devices (EPD) have been developed, with the aim of minimizing complication caused by thrombi generated during Carotid Artery Stenting (CAS). These devices are capable of capturing… read more here.

Keywords: silico hemodynamics; embolic protection; filtering evaluation; hemodynamics ... See more keywords

Comparison of embolic protection with proximal and distal protection devices: periprocedural complication, clinical outcome, and cerebral embolic lesions on diffusion-weighted magnetic resonance imaging.

Sign Up to like & get
recommendations!
Published in 2019 at "World neurosurgery"

DOI: 10.1016/j.wneu.2019.12.121

Abstract: OBJECTIVE Two main types of embolic protection devices are used during carotid artery stenting (CAS): distal protection devices (DPDs) and proximal protection devices (PPDs). We compared complications, clinical outcomes, and new ischemic lesions on diffusion… read more here.

Keywords: protection; distal protection; protection devices; embolic protection ... See more keywords

Cerebral embolic protection devices during transcatheter aortic valve implantation, the current state of the art.

Sign Up to like & get
recommendations!
Published in 2021 at "Acta cardiologica"

DOI: 10.1080/00015385.2021.1909276

Abstract: Stroke after transcatheter aortic valve (TAVI) is a devastating adverse event. The majority of these occur in the acute phase following TAVI where cerebral embolic events are frequent. Cerebral embolic protection devices (CEPD) have been… read more here.

Keywords: protection devices; embolic protection; cerebral embolic; aortic valve ... See more keywords

Cerebral embolic protection devices in transcatheter aortic valve implantation: a systematic review and meta-analysis of randomized controlled trials.

Sign Up to like & get
recommendations!
Published in 2025 at "Expert review of medical devices"

DOI: 10.1080/17434440.2025.2595252

Abstract: ABSTRACT Background This meta-analysis aimed to assess the efficacy and safety of cerebral embolic protection devices (CEPDs) in patients undergoing transcatheter aortic valve implantation (TAVI). Methods PubMed, Cochrane Central, and ScienceDirect were searched till April… read more here.

Keywords: cerebral embolic; meta analysis; embolic protection; aortic valve ... See more keywords

When absence of evidence equates to evidence of absence: the case of routine use of cerebral embolic protection devices in transcatheter aortic valve implantation

Sign Up to like & get
recommendations!
Published in 2025 at "Heart"

DOI: 10.1136/heartjnl-2025-326208

Abstract: Objectives This updated hierarchical Bayesian meta-analysis aims to integrate the latest randomised controlled trials (RCTs) on the use of cerebral embolic protection (CEP) in transcatheter aortic valve implantation (TAVI) into previously available data, providing a… read more here.

Keywords: cerebral embolic; embolic protection; cep; absence ... See more keywords

Abstract 4118076: Right Innominate Artery Endovascular Intervention Via Single Radial Access and Use Of Embolic Protection

Sign Up to like & get
recommendations!
Published in 2024 at "Circulation"

DOI: 10.1161/circ.150.suppl_1.4118076

Abstract: Introduction: The occurrence of innominate artery stenosis is less prevalent compared to subclavian artery disease. Small studies suggest up to 8% of individuals initially diagnosed with suspected subclavian steal syndrome may present with innominate artery… read more here.

Keywords: embolic protection; radial access; access; innominate artery ... See more keywords

Clinical Outcomes of Percutaneous Transcatheter Release of Stuck Mechanical Mitral Valve With Cerebral Embolic Protection

Sign Up to like & get
recommendations!
Published in 2024 at "Circulation: Cardiovascular Interventions"

DOI: 10.1161/circinterventions.124.014044

Abstract: BACKGROUND: Surgery or fibrinolysis is the currently available evidence-based treatment for obstructive mechanical valve thrombus. We reported the feasibility and short-term outcomes of percutaneous transcatheter therapy with cerebral embolic protection. Mid- and long-term outcomes remain… read more here.

Keywords: cerebral embolic; transcatheter release; embolic protection; percutaneous transcatheter ... See more keywords

Important Notes for Preventing Entrapment of Distal Filter-based Embolic Protection Device in Carotid Artery Stenting

Sign Up to like & get
recommendations!
Published in 2024 at "Neurologia medico-chirurgica"

DOI: 10.2176/jns-nmc.2024-0013

Abstract: Failure to retrieve a distal filter-based embolic protection device (EPD) is a potential complication of carotid artery stenting. This may be caused by trapping of the proximal marker of the EPD within the stent tip… read more here.

Keywords: filter; filter based; device; embolic protection ... See more keywords