Articles with "endf viii" as a keyword



Photo by cobblepot from unsplash

Covariance comparisons between ENDF/B-VII.1 and ENDF/B-VIII.0 with application for the UAM-LWR exercises

Sign Up to like & get
recommendations!
Published in 2020 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2019.107183

Abstract: Abstract In this study, the nuclear-data covariance data have been compared between ENDF/B-VII.1 and ENDF/B-VIII.0. Using NJOY2016.34, the multigroup cross-section covariance libraries based on ENDF/B-VII.1 and ENDF/B-VIII.0 have been generated respectively. From the direct comparisons… read more here.

Keywords: vii endf; endf vii; endf viii; covariance ... See more keywords
Photo from wikipedia

Performance of ENDF/B-VIII.0 library for VVER reactors criticality safety, fuel depletion and reactor dosimetry applications

Sign Up to like & get
recommendations!
Published in 2020 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2020.107736

Abstract: Abstract The latest ENDF/B nuclear data library released in 2018 is the result of a new international approach to develop evaluated nuclear data for general purpose applications. In order to use the latest ENDF/B-VIII.0 nuclear… read more here.

Keywords: safety; criticality safety; fuel depletion; safety fuel ... See more keywords
Photo by campaign_creators from unsplash

Augmented ENDF/B-VIII.0 covariance library for SCALE 6.3

Sign Up to like & get
recommendations!
Published in 2021 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2021.108353

Abstract: Abstract There are many challenges associated with the proper assessment, evaluation, interpretation and use of nuclear data covariance. There are even topics on which the international nuclear data community has not reached a consensus as… read more here.

Keywords: augmented endf; nuclear data; endf viii; covariance ... See more keywords
Photo by martindorsch from unsplash

Uncertainty comparison between ENDF/B-VIII.0 and ENDF/B-VII.1 for fast reactor BN-600 using high-precision sampling method

Sign Up to like & get
recommendations!
Published in 2021 at "Annals of Nuclear Energy"

DOI: 10.1016/j.anucene.2021.108457

Abstract: Abstract A method of using small samples to achieve high-precision related variable sequence sampling was proposed. This method mainly uses two techniques: Latin hypercube sampling method for normal distribution and transform the covariance between variables… read more here.

Keywords: high precision; viii endf; endf vii; endf viii ... See more keywords
Photo by towfiqu999999 from unsplash

Impact of the ENDF/B-VIII.0 library on MCNP6.2-computed ambient and personal dose equivalent conversion coefficients.

Sign Up to like & get
recommendations!
Published in 2022 at "Radiation protection dosimetry"

DOI: 10.1093/rpd/ncac219

Abstract: The 2018 release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library initiated several examinations of the impact of the revised nuclear data on Monte Carlo models. This study used version 6.2 of the Monte Carlo… read more here.

Keywords: personal dose; conversion coefficients; endf viii; dose equivalent ... See more keywords