Articles with "equilibrium dialysis" as a keyword



Photo from archive.org

Determining binding of polycyclic aromatic hydrocarbons to micelles formed by SDS and SOL using semi-equilibrium dialysis.

Sign Up to like & get
recommendations!
Published in 2021 at "Ecotoxicology and environmental safety"

DOI: 10.1016/j.ecoenv.2020.111635

Abstract: Micellar enhanced ultra-filtration (MEUF) is a modified ultrafiltration (UF) method that can remove small molecules that are not effectively removed by UF alone. In this work we used a similar semi-equilibrium dialysis (SED) method to… read more here.

Keywords: semi equilibrium; sol; equilibrium dialysis; log ... See more keywords
Photo from wikipedia

Improving Confidence in the Determination of Free Fraction for Highly Bound Drugs Using Bidirectional Equilibrium Dialysis.

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of pharmaceutical sciences"

DOI: 10.1016/j.xphs.2018.10.011

Abstract: Equilibrium dialysis has been widely used for the measurement of the fraction of unbound drug (fu) in plasma, but it suffers from the accuracy and reliability for low fu values. To address this concern, an… read more here.

Keywords: bound drugs; highly bound; equilibrium dialysis; bidirectional equilibrium ... See more keywords
Photo by kellysikkema from unsplash

Plate Reader Compatible 3D-Printed Device for Teaching Equilibrium Dialysis Binding Assays

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Chemical Education"

DOI: 10.1021/acs.jchemed.8b00215

Abstract: Plasma protein binding measurements are an important aspect of pharmacology and drug development. Therefore, performing these measurements can provide a valuable and highly practical learning experience for students across many scientific disciplines. Here, we describe… read more here.

Keywords: plate reader; printed device; equilibrium dialysis; device ... See more keywords
Photo from wikipedia

Reference intervals for free testosterone in adult men measured using a standardized equilibrium dialysis procedure

Sign Up to like & get
recommendations!
Published in 2022 at "Andrology"

DOI: 10.1111/andr.13310

Abstract: Free testosterone (FT) determination may be helpful in evaluating men suspected of testosterone deficiency especially in conditions with altered bindingā€protein concentrations. However, methods for measuring FT by equilibrium dialysis and reference intervals vary among laboratories. read more here.

Keywords: free testosterone; reference intervals; equilibrium dialysis;