Sign Up to like & get
recommendations!
0
Published in 2017 at "Electroanalysis"
DOI: 10.1002/elan.201700156
Abstract: We herein report the use of melamine and a low-cost screen-printed carbon electrode (SPCE) as the base matrices for the preparation of an electrochemical biosensor. Following the electrochemical polymerization of melamine, the resulting polymelamine was…
read more here.
Keywords:
printed carbon;
ige;
polymelamine;
feasibility study ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
0
Published in 2021 at "International Journal of Imaging Systems and Technology"
DOI: 10.1002/ima.22606
Abstract: When breast cancer is surgically removed, a rim of normal tissue surrounding the tumor is also removed. This rim of normal tissue is called a margin and is studied by a pathologist to determine whether…
read more here.
Keywords:
feasibility study;
ray;
carbon nanotube;
ray system ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "Microwave and Optical Technology Letters"
DOI: 10.1002/mop.32608
Abstract: We present a feasibility study of a real‐time visualization method for electromagnetic fields. When a resonant laser is used to irradiate gaseous atoms enclosed in a glass cell, the atoms absorb the light and immediately…
read more here.
Keywords:
visualization;
real time;
time visualization;
electromagnetic fields ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "Medical Physics"
DOI: 10.1002/mp.17595
Abstract: Respiratory motion is a challenge for accurate radiotherapy that may be mitigated by real‐time tracking. Commercial tracking systems utilize a hybrid external‐internal correlation model (ECM), integrating continuous external breathing monitoring with sparse X‐ray imaging of…
read more here.
Keywords:
feasibility study;
external breathing;
tumor;
model ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Medical Physics"
DOI: 10.1002/mp.17614
Abstract: High‐dose‐rate (HDR) brachytherapy using Iridium‐192 as a radiation source is widely employed in cancer treatment to deliver concentrated radiation doses while minimizing normal tissue exposure. In this treatment, the precision with which the sealed radioisotope…
read more here.
Keywords:
high dose;
feasibility study;
dose rate;
brachytherapy ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "Neurourology and Urodynamics"
DOI: 10.1002/nau.25546
Abstract: A continent catheterizable channel (CCC) may be a solution for patients with impaired bladder emptying and difficult transurethral access. Leakage of the CCC is a common complication. To prevent leakage, the pressure in the CCC…
read more here.
Keywords:
pressure;
feasibility study;
continent;
continent catheterizable ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2025 at "Sustainable Development"
DOI: 10.1002/sd.70060
Abstract: This study investigates the feasibility of integrating renewable energy sources into ski resort operations, addressing the current gap in sustainable energy solutions for high‐altitude tourism facilities. While previous research has explored general renewable energy applications,…
read more here.
Keywords:
feasibility study;
resort;
energy;
renewable energy ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2020 at "European Archives of Psychiatry and Clinical Neuroscience"
DOI: 10.1007/s00406-020-01124-z
Abstract: Quality indicators are vital for monitoring the transformation of institution-based mental health services towards the provision of person-centered mental healthcare. While several mental healthcare quality indicators have been identified as relevant and valid, their actual…
read more here.
Keywords:
mental healthcare;
quality;
feasibility study;
danube region ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2021 at "Clinical Rheumatology"
DOI: 10.1007/s10067-021-05644-4
Abstract: Introduction/objectives: Pulse intravenous (IV) methylprednisolone (MEP) is often used for severe SLE manifestations requiring hospitalization. However, the accuracy of pulse dose documentation extracted from the electronic health record (EHR) is unknown. We assessed the feasibility…
read more here.
Keywords:
among hospitalized;
icd code;
feasibility study;
ehr ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2020 at "Esophagus"
DOI: 10.1007/s10388-020-00788-9
Abstract: Robotic-assisted esophagectomy is still in the implementation phase. Robotic surgical systems refine visualization via robotically-enhanced surgical anatomy (RESA), and the stable articulated robotic arms provide precise movements. This prospective feasibility study was conducted to evaluate…
read more here.
Keywords:
esophagectomy total;
robotic esophagectomy;
esophagectomy;
prospective feasibility ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2019 at "Chemistry and Technology of Fuels and Oils"
DOI: 10.1007/s10553-019-01027-3
Abstract: We have determined the primary jet fuel performance properties that have the greatest impact on how effectively they can be used in diesel engines, requiring improvement with the help of functional additives. We have studied…
read more here.
Keywords:
jet fuel;
fuel;
feasibility study;
diesel engines ... See more keywords