Articles with "fire performance" as a keyword



Photo from wikipedia

Evaluation of fire performance of organic fire retardant free acrylic based coatings applied on various building materials by cone calorimetric method

Sign Up to like & get
recommendations!
Published in 2017 at "Fire and Materials"

DOI: 10.1002/fam.2376

Abstract: Summary Fire performance of water-based plaster systems containing acrylic copolymer binder and non-flammable mineral and ceramic fillers intended for decorative coating application was determined by cone calorimetric method. The coatings were applied on common building… read more here.

Keywords: fire performance; organic fire; calorimetric method; coatings applied ... See more keywords
Photo by joshuanewton from unsplash

Experimental investigation and numerical modelling of the fire performance for epoxy resin carbon fibre composites of variable thicknesses

Sign Up to like & get
recommendations!
Published in 2017 at "Fire and Materials"

DOI: 10.1002/fam.2381

Abstract: Summary This paper applies a unique integrated approach to determine the flammability properties of a composite material (epoxy with carbon fibre) and compares its fire behaviour at two different thicknesses (2.1 and 4.2 mm) by performing… read more here.

Keywords: fire performance; fire; carbon fibre; scale ... See more keywords
Photo by joshuanewton from unsplash

European approach to assess the fire performance of façades

Sign Up to like & get
recommendations!
Published in 2019 at "Fire and Materials"

DOI: 10.1002/fam.2878

Abstract: Several attempts have been made in the past to develop a European harmonized testing and assessment method for façades before the European commission decided to publish a call for tender on the topic. A project… read more here.

Keywords: approach assess; fire performance; performance; european approach ... See more keywords
Photo from wikipedia

Influence of reinforcement corrosion on fire performance of reinforced concrete beams

Sign Up to like & get
recommendations!
Published in 2019 at "Construction and Building Materials"

DOI: 10.1016/j.conbuildmat.2019.04.065

Abstract: Abstract Corroded steel bars frequently exist in concrete structures under chloride exposure conditions; moreover, corroded reinforced concrete (RC) is not fireproof. This paper presents an investigation on the effects of reinforcement corrosion on the fire… read more here.

Keywords: fire performance; fire; corrosion; corrosion fire ... See more keywords
Photo from wikipedia

Numerical analysis on fire performance of steel-reinforced concrete-filled steel tubular columns with square cross-section

Sign Up to like & get
recommendations!
Published in 2020 at "Structures"

DOI: 10.1016/j.istruc.2020.08.043

Abstract: Abstract This paper presents a study on the fire performance of steel-reinforced concrete-filled steel tubular (SRCFST) columns with square cross-section. The numerical models of SRCFST members, including a heat transfer analysis model and a structural… read more here.

Keywords: fire performance; fire; ratio; resistance ... See more keywords
Photo from wikipedia

Fire performance of modular wall panels: Numerical analysis

Sign Up to like & get
recommendations!
Published in 2021 at "Structures"

DOI: 10.1016/j.istruc.2021.06.111

Abstract: Abstract The Modular Building System (MBS) is increasingly popular and promoted due to the inherent advantages over conventional construction. Fire performance of a building has become a crucial design consideration because of the recent detrimental… read more here.

Keywords: fire performance; fire; wall; modular wall ... See more keywords
Photo from wikipedia

Fire performance of headed shear studs in profiled steel sheeting

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Constructional Steel Research"

DOI: 10.1016/j.jcsr.2019.105791

Abstract: Abstract The fire performance of shear connections is essential to maintain a composite action in composite beams, for which studies have previously focused on solid slab structures. Despite the popularity of profiled steel sheeting in… read more here.

Keywords: fire performance; shear studs; steel; steel sheeting ... See more keywords
Photo by mattdany from unsplash

The fire performance of Cross Laminated Timber beams

Sign Up to like & get
recommendations!
Published in 2019 at "Procedia Manufacturing"

DOI: 10.1016/j.promfg.2019.02.192

Abstract: Abstract The use of timber as a structural material in multi-storey buildings is often limited due to its combustible nature. The fire performance of the wooden members can be determined through the standard fire tests… read more here.

Keywords: performance cross; fire performance; fire; timber ... See more keywords
Photo from wikipedia

Fire Performance of CFST Triple-Limb Laced Columns

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Structural Engineering"

DOI: 10.1061/(asce)st.1943-541x.0002168

Abstract: AbstractThis paper investigates the fire performance of concrete-filled steel tubular (CFST) triple-limb laced columns. Six CFST triple-limb laced columns are tested to measure their fire resistanc... read more here.

Keywords: fire performance; triple limb; laced columns; cfst triple ... See more keywords
Photo by joshuanewton from unsplash

The effect of fibre length and matrix modification on the fire performance of thermoplastic composites: The behaviour of PP as an example of non-charring matrix

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Thermoplastic Composite Materials"

DOI: 10.1177/0892705720925134

Abstract: The fire performance of fibre-reinforced polypropylene (PP) was investigated with respect to fibre length and modification of the matrix. Fibre lengths of 3 mm, 12 mm, and continuous fibres were used as reinforcements. E-glass continuous… read more here.

Keywords: glass fibre; fire performance; fibre; fibre reinforced ... See more keywords
Photo from wikipedia

Review on the Use of Artificial Intelligence to Predict Fire Performance of Construction Materials and Their Flame Retardancy

Sign Up to like & get
recommendations!
Published in 2021 at "Molecules"

DOI: 10.3390/molecules26041022

Abstract: The evaluation and interpretation of the behavior of construction materials under fire conditions have been complicated. Over the last few years, artificial intelligence (AI) has emerged as a reliable method to tackle this engineering problem.… read more here.

Keywords: fire performance; construction; flame retardancy; review ... See more keywords