Articles with "flat plate" as a keyword



Photo from wikipedia

Response of a flat plate laminar separation bubble to Reynolds number, free-stream turbulence and adverse pressure gradient variation

Sign Up to like & get
recommendations!
Published in 2020 at "Experiments in Fluids"

DOI: 10.1007/s00348-020-02958-y

Abstract: Abstract An extensive data set describing separated flows with different Reynolds numbers (Re), free-stream turbulence intensities (Tu) and adverse pressure gradients (APG) is used for the statistical characterization of laminar separation bubbles (LSBs). Measurements were… read more here.

Keywords: adverse pressure; flat plate; stream turbulence; free stream ... See more keywords
Photo from wikipedia

Experimental investigations on the sharp leading-edge separation over a flat plate at zero incidence using particle image velocimetry

Sign Up to like & get
recommendations!
Published in 2020 at "Experiments in Fluids"

DOI: 10.1007/s00348-020-03039-w

Abstract: Leading-edge separated flow field over a sharp flat plate is experimentally investigated in Reynolds numbers ranging from 6.2 × 103 to 4.1 × 104, using particle image velocimetry (PIV) and its statistics. It was observed that the average reattachment… read more here.

Keywords: flat plate; leading edge; reynolds number; number ... See more keywords
Photo from wikipedia

Experimental and Numerical Investigation of Single-Phase Forced Convection in Flat Plate Heat Exchanger with Different Numbers of Passes

Sign Up to like & get
recommendations!
Published in 2020 at "Arabian Journal for Science and Engineering"

DOI: 10.1007/s13369-020-04906-8

Abstract: Much of the present and future technology will be based on electronic devices that are operated using an electronic clip. Due to the continuous operation of the majority of electronic devices, the efficiency of such… read more here.

Keywords: thermal resistance; plate heat; flat plate; heat exchanger ... See more keywords
Photo from wikipedia

Experimental investigation of thermal performance and entropy generation of a flat-plate solar collector filled with porous media

Sign Up to like & get
recommendations!
Published in 2017 at "Applied Thermal Engineering"

DOI: 10.1016/j.applthermaleng.2017.08.170

Abstract: Abstract The aim of the present experimental investigation is to examine the effect of metal foams as a passive thermal developer on the performance of water based flat plate solar collectors. Two similar wetted absorber collectors… read more here.

Keywords: flat plate; experimental investigation; entropy generation; performance ... See more keywords
Photo from wikipedia

Heat transfer enhancement and flow characteristics of vortex generating jet on flat plate with turbulent boundary layer

Sign Up to like & get
recommendations!
Published in 2019 at "Applied Thermal Engineering"

DOI: 10.1016/j.applthermaleng.2018.11.035

Abstract: Abstract This paper presents the results of flow and heat transfer characteristics of vortex generating jet on a flat plate. A circular jet from the pipe nozzle is injected perpendicularly to the mainstream flow on… read more here.

Keywords: heat; jet; heat transfer; flow ... See more keywords
Photo from wikipedia

Research on the in-plane temperature distribution in a PEMFC stack integrated with flat-plate heat pipe under different startup strategies and inclination angles

Sign Up to like & get
recommendations!
Published in 2020 at "Applied Thermal Engineering"

DOI: 10.1016/j.applthermaleng.2020.115741

Abstract: Abstract Thermal behavior plays an important role in the application of a proton exchange membrane fuel cell (PEMFC) stack. Flat-plate heat pipe (FPHP) is proposed as an alternative cooling device in this study. Compared with… read more here.

Keywords: flat plate; stack; pemfc; plane temperature ... See more keywords
Photo from wikipedia

Comprehensive evaluation of flat plate and parabolic dish solar collectors’ performance using different operating fluids and MWCNT nanofluid in different climatic conditions

Sign Up to like & get
recommendations!
Published in 2021 at "Energy Reports"

DOI: 10.1016/j.egyr.2021.04.046

Abstract: Abstract The use of fossil fuels leads to depletion of fuel reserves and environmental pollution. One way to achieve a sustainable future in urban areas and remote communities is to use the independent renewable energy… read more here.

Keywords: performance; collector; parabolic dish; energy ... See more keywords
Photo from wikipedia

Tetralin + fullerene C60 solutions for thermal management of flat-plate photovoltaic/thermal collector

Sign Up to like & get
recommendations!
Published in 2021 at "Energy Conversion and Management"

DOI: 10.1016/j.enconman.2021.114799

Abstract: A new composite heat transfer fluid consisting of tetralin and fullerene has been proposed for photovoltaic thermal hybrid solar harvesting. It features a unique absorption spectrum that is capable of sharply cutting off solar energy… read more here.

Keywords: energy; flat plate; photovoltaic thermal; tetralin fullerene ... See more keywords
Photo from wikipedia

Thermal and electrical performance of low-concentrating PV/T and flat-plate PV/T systems: A comparative study

Sign Up to like & get
recommendations!
Published in 2019 at "Energy"

DOI: 10.1016/j.energy.2019.04.056

Abstract: Abstract Photovoltaic/thermal (PV/T) technologies are used to comprehensively utilize photovoltaic and solar thermal, among which concentrating PV/T technology can enhance the performance of a PV/T system. To analyze the performance of a LCPV/T system with… read more here.

Keywords: performance; lcpv system; system; flat plate ... See more keywords
Photo from wikipedia

A novel dual-diameter closed-loop pulsating heat pipe for a flat plate solar collector

Sign Up to like & get
recommendations!
Published in 2021 at "Energy"

DOI: 10.1016/j.energy.2021.120751

Abstract: Abstract The main idea of this investigation is to increase the thermal efficiency of a flat plate closed-loop pulsating heat pipe solar collector by introducing a novel closed-loop pulsating heat pipe (CLPHP) with a dual-diameter… read more here.

Keywords: diameter; loop pulsating; closed loop; pulsating heat ... See more keywords
Photo from wikipedia

Review of concrete flat plate-column assemblies under fire conditions

Sign Up to like & get
recommendations!
Published in 2017 at "Fire Safety Journal"

DOI: 10.1016/j.firesaf.2017.07.004

Abstract: Abstract The flat plate-column connection is a critical region in concrete structures because of the possible punching shear failure due to brittleness, which is aggravated in the presence of fire. Many studies have been carried… read more here.

Keywords: plate column; flat plate; fire conditions; review concrete ... See more keywords