Articles with "flow imaging" as a keyword



Additional value of B‐flow imaging in arterial wall calcifications

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Clinical Ultrasound"

DOI: 10.1002/jcu.22492

Abstract: The accuracy of color Doppler ultrasonography (CDU) is hampered by the presence of arterial wall calcifications. B‐flow imaging may overcome these limitations. We present a case of a severely calcified stenosis of the right common… read more here.

Keywords: flow imaging; arterial wall; wall calcifications; additional value ... See more keywords

Quantitative Flow Imaging in Human Umbilical Vessels In Utero Using Nongated 2D Phase Contrast MRI

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Magnetic Resonance Imaging"

DOI: 10.1002/jmri.25917

Abstract: Volumetric assessment of afferent blood flow rate provides a measure of global organ perfusion. Phase‐contrast magnetic resonance imaging (PCMRI) is a reliable tool for volumetric flow quantification, but given the challenges with motion and lack… read more here.

Keywords: flow imaging; phase contrast; flow; quantitative flow ... See more keywords

An In‐depth Perspective of Aortic Arch Branching in Fetal Vascular Rings Using Spatiotemporal Image Correlation Combined With High‐definition Flow Imaging: Report of 4 Cases

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of Ultrasound in Medicine"

DOI: 10.1002/jum.14891

Abstract: On the basis of 2‐dimensional fetal echocardiographic findings, we investigated 4 different fetal vascular ring cases using spatiotemporal image correlation (STIC) combined with high‐definition (HD) flow imaging. An in‐depth 3‐dimensional perspective of aortic arch branching… read more here.

Keywords: vascular rings; flow imaging; spatiotemporal image; fetal vascular ... See more keywords

4D flow imaging with 2D‐selective excitation

Sign Up to like & get
recommendations!
Published in 2019 at "Magnetic Resonance in Medicine"

DOI: 10.1002/mrm.27769

Abstract: 4D flow MRI permits to quantify non‐invasively time‐dependent velocity vector fields, but it demands long acquisition times. 2D‐selective excitation allows to accelerate the acquisition by reducing the FOV in both phase encoding directions. In this… read more here.

Keywords: medicine; flow imaging; imaging selective; excitation ... See more keywords

Evaluation and feasibility of diagnostic heatflow imaging in patients with palpable breast lesions: a pilot study

Sign Up to like & get
recommendations!
Published in 2025 at "Archives of Gynecology and Obstetrics"

DOI: 10.1007/s00404-025-08093-5

Abstract: Breast cancer is the most common cancer in women, with early detection significantly improving outcomes. Heat flow imaging (HFI) is a non-invasive dynamic thermography method with prior tissue cooling. It has shown its potential as… read more here.

Keywords: palpable breast; study; breast lesions; flow imaging ... See more keywords

High-frame rate vector flow imaging of the carotid bifurcation

Sign Up to like & get
recommendations!
Published in 2017 at "Insights into Imaging"

DOI: 10.1007/s13244-017-0554-5

Abstract: AbstractCarotid artery atherosclerotic disease is still a significant cause of cerebrovascular morbidity and mortality. A new angle-independent technique, measuring and visualizing blood flow velocities in all directions, called vector flow imaging (VFI) is becoming available… read more here.

Keywords: carotid bifurcation; vfi; flow imaging; vector flow ... See more keywords

B-flow imaging in abdominal ultrasound: a pictorial essay

Sign Up to like & get
recommendations!
Published in 2025 at "Journal of Ultrasound"

DOI: 10.1007/s40477-025-01068-x

Abstract: B-Flow technology represents a significant advancement in vascular ultrasound imaging, offering high-resolution visualization of blood flow without the limitations inherent in conventional Doppler techniques. By employing Coded Excitation and Tissue-Blood Equalization (TBE) technologies, B-Flow enhances… read more here.

Keywords: abdominal ultrasound; imaging abdominal; flow; flow imaging ... See more keywords

[Assessment of intracardiac flows by Magnetic Resonance Imaging: The 4D Flow imaging].

Sign Up to like & get
recommendations!
Published in 2020 at "Annales de cardiologie et d'angeiologie"

DOI: 10.1016/j.ancard.2020.09.011

Abstract: 2D flow cardiac MRI is a well-established technique but has some current limitations in routine practice. New 4D flow MRI may overcome these limitations, providing dramatic dynamic imaging, easily understandable, allowing robust quantification of flows.… read more here.

Keywords: resonance imaging; flows magnetic; flow imaging; intracardiac flows ... See more keywords

Micro‐Flow Imaging as a quantitative tool to assess size and agglomeration of PLGA microparticles

Sign Up to like & get
recommendations!
Published in 2017 at "European Journal of Pharmaceutics and Biopharmaceutics"

DOI: 10.1016/j.ejpb.2017.04.002

Abstract: Graphical abstract Figure. No caption available. ABSTRACT The purpose of this study was to explore the potential of flow imaging microscopy to measure particle size and agglomeration of poly(lactic‐co‐glycolic acid) (PLGA) microparticles. The particle size… read more here.

Keywords: flow imaging; plga microparticles; size agglomeration; size ... See more keywords

Collaborative Study for Analysis of Subvisible Particles Using Flow Imaging and Light Obscuration: Experiences in Japanese Biopharmaceutical Consortium.

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of pharmaceutical sciences"

DOI: 10.1016/j.xphs.2018.08.006

Abstract: The evaluation of subvisible particles, including protein aggregates, in therapeutic protein products has been of great interest for both pharmaceutical manufacturers and regulatory agencies. To date, the flow imaging (FI) method has emerged as a… read more here.

Keywords: biopharmaceutical consortium; flow imaging; light obscuration; collaborative study ... See more keywords

Flow imaging as an alternative to non-intrusive measurements and surrogate models through vision transformers and convolutional neural networks

Sign Up to like & get
recommendations!
Published in 2023 at "Physics of Fluids"

DOI: 10.1063/5.0144700

Abstract: A numerical framework is proposed whereby flow imaging data are leveraged to extract relevant information from flowfield visualizations. To this end, a vision transformer (ViT) model is developed to predict quantities of interest from images… read more here.

Keywords: surrogate models; convolutional neural; imaging alternative; flow imaging ... See more keywords