Sign Up to like & get
recommendations!
0
Published in 2025 at "Irrigation and Drainage"
DOI: 10.1002/ird.3085
Abstract: The lack of a precise flow measurement device for terminal irrigation channel diversion often results in significant inaccuracies. To address this issue, a wide‐bottom sill flow measurement device, the ‘measurement‐control integrated side sluice gate’ (MCIS),…
read more here.
Keywords:
measurement control;
side;
accuracy;
measurement ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2017 at "Experiments in Fluids"
DOI: 10.1007/s00348-017-2390-2
Abstract: We present a spatially and temporally highly resolved flow measurement covering a large volume (~0.6 m3) in a pure thermal plume in air. The thermal plume develops above an extended heat source and is characterized by…
read more here.
Keywords:
flow measurement;
particle;
plume;
thermal plume ... See more keywords
Photo from archive.org
Sign Up to like & get
recommendations!
1
Published in 2018 at "Annals of Biomedical Engineering"
DOI: 10.1007/s10439-018-2085-8
Abstract: Cardiovascular diseases (CVD) are the leading cause of morbidity and mortality in the western world. In the last three decades, fluid dynamics investigations have been an important component in the study of the cardiovascular system…
read more here.
Keywords:
review arterial;
piv;
measurement;
phantom fabrication ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2017 at "Flow Measurement and Instrumentation"
DOI: 10.1016/j.flowmeasinst.2017.02.002
Abstract: Abstract In this paper, a method of mass flow measurement was presented based on swirl motion motivated by specific shapes of swirlers. The measuring principle of the method has been proposed by theoretical analysis and…
read more here.
Keywords:
swirl motion;
mass;
measurement;
swirler ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Flow Measurement and Instrumentation"
DOI: 10.1016/j.flowmeasinst.2017.04.002
Abstract: Abstract Accurate determination of time-of-flight (TOF) is crucially important for precise ultrasonic flow measurement. Detection of ultrasonic signal onset (USO) is considered as an effective approach to determine the actual value of TOF. The USO…
read more here.
Keywords:
signal onset;
ultrasonic signal;
flow;
flow measurement ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2017 at "Flow Measurement and Instrumentation"
DOI: 10.1016/j.flowmeasinst.2017.12.013
Abstract: Abstract Performance of an ultrasonic cross-correlation flow measurement instrument may be significantly affected by turbulence at the location of the ultrasonic sensors. In this paper, a new method of generating Synthetic Turbulence is presented, to…
read more here.
Keywords:
cross correlation;
turbulence;
ultrasonic cross;
flow measurement ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2018 at "Flow Measurement and Instrumentation"
DOI: 10.1016/j.flowmeasinst.2018.02.017
Abstract: Abstract After extensive research and development over the past three decades, a range of techniques have been proposed and developed for online continuous measurement of multiphase flow. In recent years, with the rapid development of…
read more here.
Keywords:
flow measurement;
soft computing;
multiphase flow;
computing techniques ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2020 at "Measurement"
DOI: 10.1016/j.measurement.2019.107396
Abstract: Abstract The ability to estimate the flow rate of an oil spill from a well blowout is crucial in determining the appropriate type of response and containment method, as well as to gauge the efficacy…
read more here.
Keywords:
oil spill;
deepwater horizon;
flow;
flow measurement ... See more keywords
Sign Up to like & get
recommendations!
1
Published in 2020 at "Measurement"
DOI: 10.1016/j.measurement.2020.107851
Abstract: Abstract The article analyses the impact of the Reynolds number on the estimated uncertainty of the mass flow rate measurement using an orifice plate. The objects of the research were two types of orifices: centric…
read more here.
Keywords:
reynolds number;
flow;
uncertainty;
flow measurement ... See more keywords
Photo from wikipedia
Sign Up to like & get
recommendations!
1
Published in 2020 at "Nuclear Engineering and Design"
DOI: 10.1016/j.nucengdes.2020.110644
Abstract: Abstract Reactor coolant flow measurement plays an important role in ensuring the normal and safe operation of nuclear power unit, but Helmholtz resonant cavity structure is easy to be formed in the flow measurement system,…
read more here.
Keywords:
coolant flow;
reactor coolant;
resonance;
measurement ... See more keywords
Sign Up to like & get
recommendations!
0
Published in 2024 at "AIP Advances"
DOI: 10.1063/5.0226455
Abstract: With the vigorous construction of an intelligent pipe network, an automatic flowmeter was the key to realize online flow measurement of oil and gas. Ensuring the accuracy of flow measurement was very important to achieve…
read more here.
Keywords:
oil gas;
measurement;
flow measurement;
machine learning ... See more keywords