Articles with "fluence rate" as a keyword



Photo by cdc from unsplash

Experimental study on fluence rate response of LaBr3 to pulsed X-rays

Sign Up to like & get
recommendations!
Published in 2018 at "Radiation Measurements"

DOI: 10.1016/j.radmeas.2018.04.012

Abstract: Abstract The linear response is the key property employed by a radiation detector to determine the accurate intensity of a pulse radiation field. In this study, we investigated the high fluence rate response behavior of… read more here.

Keywords: response labr3; fluence rate; rate response; response ... See more keywords
Photo by aronvisuals from unsplash

Experimental Evaluation of Turbidity Impact on the Fluence Rate Distribution in a UV Reactor Using a Microfluorescent Silica Detector.

Sign Up to like & get
recommendations!
Published in 2017 at "Environmental science & technology"

DOI: 10.1021/acs.est.7b02730

Abstract: Turbidity is a common parameter used to assess particle concentration in water using visible light. However, the fact that particles play multiple roles (e.g., scattering, refraction, and reflection) in influencing the optical properties of aqueous… read more here.

Keywords: silica detector; using microfluorescent; particle; turbidity ... See more keywords
Photo from wikipedia

Fluence Rate Determines PDT Efficiency in Breast Cancer Cells Displaying Different GSH Levels

Sign Up to like & get
recommendations!
Published in 2019 at "Photochemistry and Photobiology"

DOI: 10.1111/php.13182

Abstract: Photodynamic therapy (PDT) appears as a promising alternative in the treatment of breast cancer since it can be highly effective in curing cancer while preserving normal tissue. However, predicting outcomes in PDT still constitutes a… read more here.

Keywords: fluence rate; fluence; rate; breast cancer ... See more keywords
Photo by ale_s_bianchi from unsplash

On the Development of a Light Dosimetry Planning Tool for Photodynamic Therapy in Arbitrary Shaped Cavities: Initial Results

Sign Up to like & get
recommendations!
Published in 2020 at "Photochemistry and Photobiology"

DOI: 10.1111/php.13216

Abstract: Previous dosimetric studies during photodynamic therapy (PDT) of superficial lesions within a cavity such as the nasopharynx, demonstrated significant intra‐ and interpatient variations in fluence rate build‐up as a result of tissue surface re‐emitted and… read more here.

Keywords: fluence rate; photodynamic therapy; dosimetry; therapy ... See more keywords
Photo from wikipedia

Fluence rate directly derived from photon pathlengths: a tool for Monte Carlo simulations in biomedical optics.

Sign Up to like & get
recommendations!
Published in 2022 at "Biomedical optics express"

DOI: 10.1364/boe.477339

Abstract: In biomedical optics, the mean fluence rate of photons, assessed in a sub-volume of a propagating medium, is classically obtained in Monte Carlo simulations by taking into account the power deposited by the absorbed photons… read more here.

Keywords: biomedical optics; monte carlo; fluence rate; carlo simulations ... See more keywords