Articles with "fracture reduction" as a keyword



Intranasal fentanyl and inhaled nitrous oxide for fracture reduction: The FAN observational study

Sign Up to like & get
recommendations!
Published in 2017 at "American Journal of Emergency Medicine"

DOI: 10.1016/j.ajem.2017.01.004

Abstract: Introduction: Procedural sedation and analgesia (PSA) are frequently used for fracture reduction in pediatric emergency departments (ED). Combining intranasal (IN) fentanyl with inhalation of nitrous oxide (N2O) allow for short recovery time and obviates painful… read more here.

Keywords: reduction; nitrous oxide; intranasal fentanyl; fracture reduction ... See more keywords

3D Image-Guided Robotic System for Bone Fracture Reduction

Sign Up to like & get
recommendations!
Published in 2022 at "IEEE Robotics and Automation Letters"

DOI: 10.1109/lra.2022.3150880

Abstract: To overcome possible drawbacks of bone fracture reduction such as risks of malrotation, radiation exposure, as well as laborious traction, image-guided robotic surgery systems have been proposed. However, the use of optical tracking systems (OTS)… read more here.

Keywords: system; bone fracture; fracture reduction; reduction ... See more keywords

Pelvic Fracture Reduction Planning via Joint Shape-Intensity Reference.

Sign Up to like & get
recommendations!
Published in 2025 at "IEEE transactions on medical imaging"

DOI: 10.1109/tmi.2025.3621670

Abstract: Pelvic fracture reduction planning is clinically critical yet technically demanding due to the complex anatomical structure of pelvis and the topological discontinuities introduced by fractures. Existing computer-assisted planning approaches dominantly rely on shape-based models, overlooking… read more here.

Keywords: fracture; fracture reduction; shape; reduction planning ... See more keywords

Comparison of two external fixator systems for fracture reduction during minimally invasive plate osteosynthesis in simulated antebrachial fractures

Sign Up to like & get
recommendations!
Published in 2017 at "Veterinary Surgery"

DOI: 10.1111/vsu.12687

Abstract: OBJECTIVE To compare the Minimally Invasive Reduction Instrumentation System (MIRIS) to a two-ring circular fixator construct (CFC) for indirect reduction during minimally invasive plate osteosynthesis. STUDY DESIGN Cadaveric antebrachial fracture model. ANIMALS Ten skeletally mature… read more here.

Keywords: reduction minimally; reduction; invasive plate; minimally invasive ... See more keywords
Photo from wikipedia

Human-robot-robot cooperative control using positioning robot and 1-DOF traction device for robot-assisted fracture reduction system

Sign Up to like & get
recommendations!
Published in 2022 at "Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine"

DOI: 10.1177/09544119221083140

Abstract: While performing musculoskeletal long bone fracture reduction surgery, assistant surgeons can often suffer from physical fatigue as they provide resistance against the tension from surrounding muscles pulling on the patient’s broken bones. These days, robotic… read more here.

Keywords: fracture reduction; positioning robot; robot; traction device ... See more keywords

Assessing effectiveness of ABCDE Framework for teaching condylar fracture reduction in dental education: a mixed methods study

Sign Up to like & get
recommendations!
Published in 2025 at "BMC Medical Education"

DOI: 10.1186/s12909-025-07705-7

Abstract: Managing displaced proximal segments in mandibular condylar fractures remains challenging due to complex anatomy and limited surgical visibility. Conventional teaching methods in oral and maxillofacial surgery (OMFS) often inadequately address these challenges. This study evaluates… read more here.

Keywords: abcde framework; condylar fracture; fracture reduction; framework ... See more keywords
Photo from wikipedia

Inter-rater variability of three-dimensional fracture reduction planning according to the educational background

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Orthopaedic Surgery and Research"

DOI: 10.1186/s13018-021-02312-w

Abstract: Background Computer-assisted three-dimensional (3D) planning is increasingly delegated to biomedical engineers. So far, the described fracture reduction approaches rely strongly on the performance of the users. The goal of our study was to analyze the… read more here.

Keywords: three dimensional; reduction; planning; background ... See more keywords

Intelligent robot-assisted fracture reduction system for the treatment of unstable pelvic fractures

Sign Up to like & get
recommendations!
Published in 2024 at "Journal of Orthopaedic Surgery and Research"

DOI: 10.1186/s13018-024-04761-5

Abstract: Precise and minimally invasive closed reduction is the premise of minimally invasive internal fixation. This paper aims to explore the safety and efficacy of a robot-assisted fracture reduction system (RAFR) in the treatment of pelvic… read more here.

Keywords: system; fracture reduction; pelvic fractures; robot assisted ... See more keywords

Study on the Modeling and Compensation Method of Pose Error Analysis for the Fracture Reduction Robot

Sign Up to like & get
recommendations!
Published in 2022 at "Micromachines"

DOI: 10.3390/mi13081186

Abstract: Background: In the process of fracture reduction, there are some errors between the actual trajectory and the ideal trajectory due to mechanism errors, which would affect the smooth operation of fracture reduction. To this end,… read more here.

Keywords: fracture; error; fracture reduction; reduction ... See more keywords