Articles with "gmi" as a keyword



Photo by averey from unsplash

Giant magnetoimpedance based immunoassay for cardiac biomarker myoglobin

Sign Up to like & get
recommendations!
Published in 2017 at "Analytical Methods"

DOI: 10.1039/c7ay00981j

Abstract: Herein, a novel method for the detection of the cardiac biomarker myoglobin (Mb) is proposed by using an integrated giant magnetoimpedance (GMI) based immunosensor. The GMI sensor integrates magnetic sensing elements and a gold film.… read more here.

Keywords: giant magnetoimpedance; cardiac biomarker; biomarker myoglobin; gmi ... See more keywords
Photo by homajob from unsplash

Performance of the Glucose Management Indicator (GMI) in Type 2 Diabetes.

Sign Up to like & get
recommendations!
Published in 2023 at "Clinical chemistry"

DOI: 10.1093/clinchem/hvac210

Abstract: BACKGROUND The glucose management indicator (GMI) is an estimated measure of hemoglobin A1c (HbA1c) recommended for the management of persons with diabetes using continuous glucose monitoring (CGM). However, GMI was derived primarily in young adults… read more here.

Keywords: management indicator; hba1c; gmi; type diabetes ... See more keywords
Photo from wikipedia

Investigation the influence of structure parameters on giant-magnetoimpedance effect measured by non-contact method

Sign Up to like & get
recommendations!
Published in 2020 at "Sensor Review"

DOI: 10.1108/sr-07-2019-0169

Abstract: This paper aims to investigate the influence of structure parameters on giant-magnetoimpedance (GMI) effect measured by non-contact method.,The GMI sensor contains a Co-based internal magnetic core fabricated by laser cutting and an external solenoid. The… read more here.

Keywords: contact method; measured non; contact; gmi ... See more keywords
Photo by nordwood from unsplash

Impact of Adjustment of the Static Working Point on the 1/f Noise in a Negative Feedback GMI Magnetic Sensor

Sign Up to like & get
recommendations!
Published in 2019 at "IEEE Sensors Journal"

DOI: 10.1109/jsen.2019.2925738

Abstract: The resolution of giant magneto-impedance (GMI)-based magnetic sensor is limited by its equivalent magnetic noise level. It presents a white noise and a low-frequency 1/f noise behavior. Previous works have showed that the white noise… read more here.

Keywords: static working; gmi; noise; sensor ... See more keywords
Photo by kellysikkema from unsplash

Theoretical and Experimental Investigation of Temperature-Compensated Off-Diagonal GMI Magnetometer and Its Long-Term Stability

Sign Up to like & get
recommendations!
Published in 2020 at "IEEE Sensors Journal"

DOI: 10.1109/jsen.2020.2988939

Abstract: The off-diagonal Giant magneto-impedance magnetometer (GMI) offset drift was investigated regarding its temperature dependence and long-term stability. First of all, the theoretical GMI effect model was upgraded as to include temperature dependency which was presumed… read more here.

Keywords: gmi; stability; temperature; term stability ... See more keywords
Photo by lureofadventure from unsplash

Evaluation of the Imaginary Part of the Magnetic Susceptibility, $\chi ^{\prime \prime }$ , and Application to the Estimation of the Low Frequency, 1/ $f$ , Excess Noise in GMI Sensors

Sign Up to like & get
recommendations!
Published in 2017 at "IEEE Transactions on Magnetics"

DOI: 10.1109/tmag.2017.2686805

Abstract: The equivalent magnetic noise spectral density of giant magnetoimpedance (GMI)-based sensors exhibits a low-frequency excess noise inversely proportional to the frequency (1/f noise). In order to enhance the performance and reach the ultimate and intrinsic… read more here.

Keywords: excess noise; noise; low frequency; chi prime ... See more keywords
Photo by strong18philip from unsplash

Learning Representations by Graphical Mutual Information Estimation and Maximization.

Sign Up to like & get
recommendations!
Published in 2022 at "IEEE transactions on pattern analysis and machine intelligence"

DOI: 10.1109/tpami.2022.3147886

Abstract: The rich content in various real-world networks such as social networks, biological networks, and communication networks provides unprecedented opportunities for unsupervised machine learning on graphs. This paper investigates the fundamental problem of preserving and extracting… read more here.

Keywords: mutual information; graphical mutual; gmi; information estimation ... See more keywords
Photo by aminmoshrefi from unsplash

Abstract 1757: Mobilization of tumor-primed, marrow-infiltrating lymphocytes into peripheral blood with inhibitors of E-selectin or E-selectin and CXCR4

Sign Up to like & get
recommendations!
Published in 2018 at "Immunology"

DOI: 10.1158/1538-7445.am2018-1757

Abstract: Marrow-infiltrating lymphocytes (MILs) primed to tumor antigens have been described in patients with hematologic malignancies and in metastatic disease arising from carcinomas. The presence of tumor-reactive MILs in these patients has suggested the possibility of… read more here.

Keywords: peripheral blood; selectin cxcr4; gmi; tumor ... See more keywords
Photo by arstinchen from unsplash

Abstract LB164: A novel glycomimetic compound (GMI-1757) with dual functional antagonism to E-selectin and galectin-3 attenuates fibrosis, facilitates mononuclear cell infiltration and optimizes anti-PD-L1 therapeutic activity in a pancreatic adenocarcinoma model

Sign Up to like & get
recommendations!
Published in 2021 at "Immunology"

DOI: 10.1158/1538-7445.am2021-lb164

Abstract: The inability to generate robust anti-tumor responses with therapeutics affecting T cell function has been ascribed to multiple parameters such as the tumor fibrotic compartment and the degree/makeup of host infiltrative cells. These parameters are… read more here.

Keywords: gmi; gmi 1757; fibrosis; infiltration ... See more keywords
Photo by videoqueenstl from unsplash

Glycemic Outcomes During Real-World Hybrid Closed-Loop System Use by Individuals With Type 1 Diabetes in the United States.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of diabetes science and technology"

DOI: 10.1177/19322968221088608

Abstract: BACKGROUND Glycemic outcomes during real-world hybrid closed-loop (HCL) system use by individuals with type 1 diabetes, in the United States, were retrospectively analyzed. METHODS Hybrid closed-loop system data voluntarily uploaded to Carelinkā„¢ personal software from… read more here.

Keywords: system; system use; gmi; real world ... See more keywords
Photo by aditi_gautam from unsplash

Discordance Between Glycated Hemoglobin A1c and the Glucose Management Indicator in People With Diabetes and Chronic Kidney Disease.

Sign Up to like & get
recommendations!
Published in 2022 at "Journal of diabetes science and technology"

DOI: 10.1177/19322968221092050

Abstract: INTRODUCTION Assessment of glucose exposure via glycated hemoglobin A1c (HbA1c) has limitations for interpretation in individuals with diabetes and chronic kidney disease (CKD). The glucose management indicator (GMI) derived from continuous glucose monitoring (CGM) data… read more here.

Keywords: hemoglobin a1c; hba1c; gmi; ckd ... See more keywords