Articles with "hip joint" as a keyword



Photo from wikipedia

Adjacent segment disease on hip joint as a complication of spinal fusion surgery including sacroiliac joint fixation

Sign Up to like & get
recommendations!
Published in 2021 at "European Spine Journal"

DOI: 10.1007/s00586-020-06700-4

Abstract: Recently, the number of adult spinal deformity surgeries including sacroiliac joint fixation (SIJF) by using an S2 alar iliac screw or iliac screw has increased to avoid the distal junctional failure. However, we occasionally experienced… read more here.

Keywords: spinal fusion; surgery; hip; surgery including ... See more keywords
Photo from wikipedia

Comment on “Tumor necrosis factor inhibitors prevent structural damage in hips in ankylosing spondylitis—time to reconsider treatment guidelines? A case series and review of literature”

Sign Up to like & get
recommendations!
Published in 2021 at "Clinical Rheumatology"

DOI: 10.1007/s10067-021-05683-x

Abstract: Dear Editor, We read with great interest the article by Rocha et al. entitled “Tumor necrosis factor inhibitors prevent structural damage in hips in ankylosing spondylitis—time to reconsider treatment guidelines? A case series and review… read more here.

Keywords: structural damage; hip; treatment; case ... See more keywords
Photo from wikipedia

Forget the Greater Trochanter! Hip Joint Access With the 12 O’clock Portal in Hip Arthroscopy

Sign Up to like & get
recommendations!
Published in 2019 at "Arthroscopy Techniques"

DOI: 10.1016/j.eats.2019.01.017

Abstract: Most surgeons rely on the greater trochanter as the reference point to establish the anterolateral portal. Nevertheless, we believe that the anterosuperior iliac spine is a more reliable landmark. Unlike the greater trochanter, it is… read more here.

Keywords: hip; arthroscopy; hip joint; clock portal ... See more keywords
Photo by majestical_jasmin from unsplash

Progressive failure analysis of a hip joint based on extended finite element method

Sign Up to like & get
recommendations!
Published in 2020 at "Engineering Failure Analysis"

DOI: 10.1016/j.engfailanal.2020.104829

Abstract: Abstract The present work adopted the extended finite element method (XFEM) to predict the progressive failure of an artificially cemented hip joint. The three-dimensional finite element (3DFE) method was employed to simulate the cemented hip… read more here.

Keywords: finite element; hip; hip joint; cemented hip ... See more keywords
Photo from archive.org

Tribological performances of symmetrically micro-textured Ti-6Al-4V alloy for hip joint

Sign Up to like & get
recommendations!
Published in 2020 at "International Journal of Mechanical Sciences"

DOI: 10.1016/j.ijmecsci.2020.105736

Abstract: Abstract This study investigates the tribological performances, i.e., reduction in coefficients of friction (COF), and surface wear of symmetrically micro-textured Ti-6Al-4V for the application of metal-on-metal hip joint. Symmetrical configurations of micro-textures, namely, micro-dimple with… read more here.

Keywords: hip joint; geometry; tribological performances; micro textured ... See more keywords
Photo from wikipedia

In vivo hip joint loads and pedal forces during ergometer cycling.

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of biomechanics"

DOI: 10.1016/j.jbiomech.2017.06.047

Abstract: The rising prevalence of osteoarthritis and an increase in total hip replacements calls for attention to potential therapeutic activities. Cycling is considered as a low impact exercise for the hip joint and hence recommended. However,… read more here.

Keywords: joint loads; vivo hip; hip; loads pedal ... See more keywords
Photo from wikipedia

Individuals with mild-to-moderate hip osteoarthritis walk with lower hip joint contact forces despite higher levels of muscle co-contraction compared to healthy individuals.

Sign Up to like & get
recommendations!
Published in 2020 at "Osteoarthritis and cartilage"

DOI: 10.1016/j.joca.2020.04.008

Abstract: OBJECTIVE To compare hip joint contact forces (HJCF), hip muscle forces, and hip muscle co-contraction levels between individuals with mild-to-moderate hip osteoarthritis (OA) and healthy controls during walking. DESIGN Eighteen participants with mild-to-moderate hip OA… read more here.

Keywords: muscle; mild moderate; hip; contraction ... See more keywords
Photo from wikipedia

Reliability of the acetabular reconstruction technique using autogenous bone graft from resected femoral head in hip dysplasia: Influence of the change of hip joint center on clinical outcome.

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of orthopaedics"

DOI: 10.1016/j.jor.2017.07.007

Abstract: INTRODUCTION The previous studies have not reached on consensus as to the outcome of acetabular reconstruction with autogenous bone graft for dysplastic hips, especially in severe cases such as Crowe type IV. The current study… read more here.

Keywords: range; hip; joint center; hip joint ... See more keywords
Photo from wikipedia

Ischiofemoral hip ligament reconstructions for recurrent posterior total hip joint dislocations.

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of orthopaedics"

DOI: 10.1016/j.jor.2018.08.017

Abstract: Objective Recurrent dislocations of a total hip joint replacement are a difficult problem to address. We present a technique for reconstructing the ischiofemoral ligament of the hip to prevent recurrent posterior dislocations. Methods This is… read more here.

Keywords: recurrent posterior; hip; ischiofemoral hip; hip joint ... See more keywords
Photo from wikipedia

The machining process and multi-sensor measurements of the friction components of total hip joint prosthesis

Sign Up to like & get
recommendations!
Published in 2018 at "Measurement"

DOI: 10.1016/j.measurement.2017.10.045

Abstract: Abstract The paper presents issues concerning the manufacturing process and investigation of surface topography of polymeric sockets and ceramic balls incorporated into total hip joint prosthesis. In the manufacturing process of friction pairs, a crucial… read more here.

Keywords: topography; machining process; microscopy; friction ... See more keywords
Photo from academic.microsoft.com

Optimizing the tribological behavior of tantalum carbide coating for the bearing in total hip joint replacement

Sign Up to like & get
recommendations!
Published in 2018 at "Vacuum"

DOI: 10.1016/j.vacuum.2018.01.050

Abstract: Abstract Tantalum carbide (TaC) coatings deposited using DC reactive sputtering, have been scrutinized with XPS, XRD, TEM, nanoindenter, and tribological tests in ambient air and simulated body fluid (SBF). The carbon (C) content of the… read more here.

Keywords: hip joint; tantalum carbide; total hip; tac coatings ... See more keywords