Articles with "implant retained" as a keyword



Photo from wikipedia

Mandibular implant-retained overdenture relining procedure with an attachment system: A step-by-step demonstration of the technique.

Sign Up to like & get
recommendations!
Published in 2018 at "Journal of the American Dental Association"

DOI: 10.1016/j.adaj.2017.07.001

Abstract: BACKGROUND AND OVERVIEW Because of continuous alveolar bone resorption, implant-retained overdentures need to be relined. The purpose of this study was to describe a method for relining an implant-retained overdenture. CASE DESCRIPTION The authors present… read more here.

Keywords: technique; step step; mandibular implant; implant retained ... See more keywords
Photo from wikipedia

Systematic review of literature: functional outcomes of implant‐prosthetic treatment in patients with surgical resection for oral cavity tumors

Sign Up to like & get
recommendations!
Published in 2017 at "Journal of Investigative and Clinical Dentistry"

DOI: 10.1111/jicd.12207

Abstract: The current systematic review was performed to assess the functional outcomes of implant-prosthetic treatment on patients who have had surgical resection of oral cavity tumors. The assessment of function, satisfaction, or quality of life (QoL)… read more here.

Keywords: implant retained; implant prosthetic; prosthetic treatment; retained prosthesis ... See more keywords
Photo by tcooper86 from unsplash

Oral Rehabilitation with Implant‐Retained Overdenture in a Patient with Down Syndrome

Sign Up to like & get
recommendations!
Published in 2019 at "Journal of Prosthodontics"

DOI: 10.1111/jopr.12596

Abstract: Down syndrome, known as trisomy 21, is the most common chromosomal disorder. The disorder affects mental and systemic development as well as oral structure, including dental anomalies, high susceptibility of periodontal disease, and poor quality… read more here.

Keywords: oral rehabilitation; patient syndrome; implant retained; rehabilitation ... See more keywords
Photo from wikipedia

Unsplinted Attachments and Patient-Reported Outcome Measures (PROMs) in 2-Implant-Retained Mandibular Overdentures: A Systematic Review

Sign Up to like & get
recommendations!
Published in 2022 at "International Journal of Dentistry"

DOI: 10.1155/2022/5955847

Abstract: Introduction The purpose of this review is to compare randomized clinical trials evaluating the patient-reported outcome measures (PROMs) using different unsplinted attachment systems in 2-implant-retained mandibular overdentures (2IRMODs). A focus question (as per PICOS) was… read more here.

Keywords: patient reported; retained mandibular; implant retained; ball attachments ... See more keywords
Photo from wikipedia

Occlusion on a Single Implant-Supported Crown: Any differences?

Sign Up to like & get
recommendations!
Published in 2022 at "Primary Dental Journal"

DOI: 10.1177/20501684221100944

Abstract: Dental implants react biomechanically to the occlusal forces placed on them, in a different fashion to teeth, which can make them prone to overloading. This can lead to a range of mechanical problems, including screw… read more here.

Keywords: occlusion single; implant retained; implant supported; supported crown ... See more keywords
Photo from wikipedia

Fabrication of immediately loaded implant-retained maxillary overdenture with flapless surgery using a CAD/CAM surgical guide: A technical report

Sign Up to like & get
recommendations!
Published in 2022 at "Primary Dental Journal"

DOI: 10.1177/20501684221133418

Abstract: This report describes a digital workflow and two-year follow-up of an immediately loaded implant-retained overdenture using flapless surgery and a computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guide. A prosthetically-driven approach, utilising a three-dimensional (3D) planning software… read more here.

Keywords: maxillary overdenture; surgical guide; overdenture; implant retained ... See more keywords
Photo from wikipedia

Can implant-retained overdenture components cause damage to the opposing natural dentition?

Sign Up to like & get
recommendations!
Published in 2021 at "Dental Update"

DOI: 10.12968/denu.2021.48.7.571

Abstract: This clinical case series highlights an under-reported and often unidentified complication of implant-retained overdentures that may leave patients with a risk of long-term discomfort and preventable damage to the opposing dentition. A variety of cases… read more here.

Keywords: dentition; damage opposing; components cause; implant retained ... See more keywords
Photo from wikipedia

Does number of implants or type of attachment affect patient satisfaction with implant-retained mandibular overdentures?

Sign Up to like & get
recommendations!
Published in 2020 at "Journal of Osseointegration"

DOI: 10.23805/jo.2020.12.01.04

Abstract: Aim This study aimed to determine, from the patients’ perspective, the optimal number of implants and the type of attachment used to support a mandibular overdenture. Materials and methods This study was conducted with 166… read more here.

Keywords: implants type; satisfaction; type attachment; number implants ... See more keywords
Photo from wikipedia

Bar fracture of implant-retained overdenture: Protocol of a systematic review and meta-analysis

Sign Up to like & get
recommendations!
Published in 2021 at "Journal of Osseointegration"

DOI: 10.23805/jo.2021.13.02.7

Abstract: Aim The fractured bar is a common prosthetic complication that deteriorates the patient’s experience and prosthesis functionality; therefore, we aim to determine risk factors, prevalence, and incidence of bar fracture. Methods We will conduct a… read more here.

Keywords: review; bar; bar fracture; systematic review ... See more keywords
Photo from wikipedia

Effect of Various Retentive Element Materials on Retention of Mandibular Implant-Retained Overdentures

Sign Up to like & get
recommendations!
Published in 2022 at "Molecules"

DOI: 10.3390/molecules27123925

Abstract: This study aimed to examine the retentive characteristics of each retentive element material and the effects from thermocycling using the two implant-retained mandibular overdenture model. Two stud abutments and three retentive element materials; nylon, polyetheretherketone… read more here.

Keywords: retention; implant retained; element materials; retentive element ... See more keywords